Changes for page 13 HMI Internal Registers
                  Last modified by xingzhi lin on 2025/10/30 15:10
              
      
      From version  6.2 
    
    
              edited by xingzhi lin
        
on 2025/10/30 14:48
     on 2025/10/30 14:48
      Change comment:
              There is no comment for this version
          
         
      To version  6.5 
    
    
              edited by xingzhi lin
        
on 2025/10/30 15:10
     on 2025/10/30 15:10
      Change comment:
              There is no comment for this version
          
         Summary
- 
          Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
- 
      - Content
-   ... ... @@ -156,8 +156,65 @@ 156 156 * 0: Disable exclusive mode 157 157 * 1: Enable exclusive mode 158 158 ))) 159 -|=HSW11773|Control auto user logout | 159 +|=HSW11773|Control auto user logout |((( 160 +Controls the enable state of auto user logout. 160 160 162 +* HSX11773.0: =0 Follow project configuration 163 +* HSX11773.0: =1 Follow address configuration 164 +* HSX11773.1: =0 Disable auto logout 165 +* HSX11773.1: =1 Enable auto logout 166 +))) 167 +|=HSW11774|Auto user logout waiting time|Sets the waiting time before automatic logout (1–255 minutes). 168 +|=((( 169 +==== **HSW11775** ==== 170 +)))|Enable NTP time synchronization|((( 171 +* 1: Enable NTP 172 +* 0: Disable NTP 173 +))) 174 +|=HSW11776|Immediate time synchronization|Perform immediate NTP sync after device startup. 175 +|=HSW11777~~11780|Primary time server IP (required when NTP is enabled)|Each register represents one byte of the IP address (high to low). 176 +|=HSW11781~~11784|Second time server IP (optional)|Each register represents one byte of the IP address (high to low). 177 +|=HSW11785~~11788|Third time server IP (optional)|Each register represents one byte of the IP address (high to low). 178 +|=HSW11789~~11792|Fourth time server IP (optional)|Each register represents one byte of the IP address (high to low). 179 +|=HSW11793|Time synchronization period|((( 180 + 181 + 182 +High byte of time synchronization period 183 +))) 184 +|=HSW11794|Time synchronization period|((( 185 + 186 + 187 +Low byte of time synchronization period 188 +))) 189 +|=HSW11795|Enable daylight saving time (DST)|((( 190 +* 1: Enable DST 191 +* 0: Disable DST 192 +))) 193 +|=HSW11796|Time adjustment|Hour adjustment 194 +|=HSW11797|Time adjustment|Minute adjustment 195 +|=HSW11798~~11807|DST start and end configuration|((( 196 +* Start month: 1–12 197 +* Week of month: 1–5 198 +* Day of week: 0–6 (0 = Sunday) 199 +* Hour: 0–23 200 +* Minute: 0–59 201 +* End month/week/day/hour/minute follow the same format. 202 +))) 203 +|=HSW11808|Whether currently in daylight saving time|((( 204 +* 1: In DST 205 +* 0: Not in DST 206 +))) 207 +|=HSW11811|Watchdog mode configuration|((( 208 +* 1: Register mode 209 +* 0: Project mode 210 +))) 211 +|=HSW11812|Enable watchdog|((( 212 +* 1: Enable 213 +* 0: Disable 214 +))) 215 +|=HSW11813|Watchdog timeout setting|Unit: second 216 +|=HSW11814|Trigger watchdog|=0 Reboot 217 + 161 161 = **Special data area (HSW/HSX)** = 162 162 163 163 It is used for system special registers (reserved by system). 
 
 
  