... ... @@ -156,8 +156,63 @@
156 156  * 0: Disable exclusive mode
157 157  * 1: Enable exclusive mode
158 158  )))
159 -|=HSW11773|Control auto user logout |
159 +|=HSW11773|Control auto user logout |(((
160 +Controls the enable state of auto user logout.
160 160  
162 +* HSX11773.0: =0 Follow project configuration
163 +* HSX11773.0: =1 Follow address configuration
164 +* HSX11773.1: =0 Disable auto logout
165 +* HSX11773.1: =1 Enable auto logout
166 +)))
167 +|=HSW11774|Auto user logout waiting time|Sets the waiting time before automatic logout (1–255 minutes).
168 +|=HSW11775|Enable NTP time synchronization|(((
169 +* 1: Enable NTP
170 +* 0: Disable NTP
171 +)))
172 +|=HSW11776|Immediate time synchronization|Perform immediate NTP sync after device startup.
173 +|=HSW11777~~11780|Primary time server IP (required when NTP is enabled)|Each register represents one byte of the IP address (high to low).
174 +|=HSW11781~~11784|Second time server IP (optional)|Each register represents one byte of the IP address (high to low).
175 +|=HSW11785~~11788|Third time server IP (optional)|Each register represents one byte of the IP address (high to low).
176 +|=HSW11789~~11792|Fourth time server IP (optional)|Each register represents one byte of the IP address (high to low).
177 +|=HSW11793|Time synchronization period|(((
178 +
179 +
180 +High byte of time synchronization period
181 +)))
182 +|=HSW11794|Time synchronization period|(((
183 +
184 +
185 +Low byte of time synchronization period
186 +)))
187 +|=HSW11795|Enable daylight saving time (DST)|(((
188 +* 1: Enable DST
189 +* 0: Disable DST
190 +)))
191 +|=HSW11796|Time adjustment|Hour adjustment
192 +|=HSW11797|Time adjustment|Minute adjustment
193 +|=HSW11798~~11807|DST start and end configuration|(((
194 +* Start month: 1–12
195 +* Week of month: 1–5
196 +* Day of week: 0–6 (0 = Sunday)
197 +* Hour: 0–23
198 +* Minute: 0–59
199 +* End month/week/day/hour/minute follow the same format.
200 +)))
201 +|=HSW11808|Whether currently in daylight saving time|(((
202 +* 1: In DST
203 +* 0: Not in DST
204 +)))
205 +|=HSW11811|Watchdog mode configuration|(((
206 +* 1: Register mode
207 +* 0: Project mode
208 +)))
209 +|=HSW11812|Enable watchdog|(((
210 +* 1: Enable
211 +* 0: Disable
212 +)))
213 +|=HSW11813|Watchdog timeout setting|Unit: second
214 +|=HSW11814|Trigger watchdog|=0 Reboot
215 +
161 161  = **Special data area (HSW/HSX)** =
162 162  
163 163  It is used for system special registers (reserved by system).