Changes for page 13 HMI Internal Registers
                  Last modified by xingzhi lin on 2025/10/30 15:10
              
      
      From version  6.3 
    
    
              edited by xingzhi lin
        
on 2025/10/30 15:02
     on 2025/10/30 15:02
      Change comment:
              There is no comment for this version
          
         
      To version  7.1 
    
    
              edited by xingzhi lin
        
on 2025/10/30 15:10
     on 2025/10/30 15:10
      Change comment:
              There is no comment for this version
          
         Summary
- 
          Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
- 
      - Content
-   ... ... @@ -190,6 +190,30 @@ 190 190 * 1: Enable DST 191 191 * 0: Disable DST 192 192 ))) 193 +|=HSW11796|Time adjustment|Hour adjustment 194 +|=HSW11797|Time adjustment|Minute adjustment 195 +|=HSW11798~~11807|DST start and end configuration|((( 196 +* Start month: 1–12 197 +* Week of month: 1–5 198 +* Day of week: 0–6 (0 = Sunday) 199 +* Hour: 0–23 200 +* Minute: 0–59 201 +* End month/week/day/hour/minute follow the same format. 202 +))) 203 +|=HSW11808|Whether currently in daylight saving time|((( 204 +* 1: In DST 205 +* 0: Not in DST 206 +))) 207 +|=HSW11811|Watchdog mode configuration|((( 208 +* 1: Register mode 209 +* 0: Project mode 210 +))) 211 +|=HSW11812|Enable watchdog|((( 212 +* 1: Enable 213 +* 0: Disable 214 +))) 215 +|=HSW11813|Watchdog timeout setting|Unit: second 216 +|=HSW11814|Trigger watchdog|=0 Reboot 193 193 194 194 = **Special data area (HSW/HSX)** = 195 195 
 
 
  