... ... @@ -165,9 +165,7 @@
165 165  * HSX11773.1: =1 Enable auto logout
166 166  )))
167 167  |=HSW11774|Auto user logout waiting time|Sets the waiting time before automatic logout (1–255 minutes).
168 -|=(((
169 -==== **HSW11775** ====
170 -)))|Enable NTP time synchronization|(((
168 +|=HSW11775|Enable NTP time synchronization|(((
171 171  * 1: Enable NTP
172 172  * 0: Disable NTP
173 173  )))
... ... @@ -190,6 +190,30 @@
190 190  * 1: Enable DST
191 191  * 0: Disable DST
192 192  )))
191 +|=HSW11796|Time adjustment|Hour adjustment
192 +|=HSW11797|Time adjustment|Minute adjustment
193 +|=HSW11798~~11807|DST start and end configuration|(((
194 +* Start month: 1–12
195 +* Week of month: 1–5
196 +* Day of week: 0–6 (0 = Sunday)
197 +* Hour: 0–23
198 +* Minute: 0–59
199 +* End month/week/day/hour/minute follow the same format.
200 +)))
201 +|=HSW11808|Whether currently in daylight saving time|(((
202 +* 1: In DST
203 +* 0: Not in DST
204 +)))
205 +|=HSW11811|Watchdog mode configuration|(((
206 +* 1: Register mode
207 +* 0: Project mode
208 +)))
209 +|=HSW11812|Enable watchdog|(((
210 +* 1: Enable
211 +* 0: Disable
212 +)))
213 +|=HSW11813|Watchdog timeout setting|Unit: second
214 +|=HSW11814|Trigger watchdog|=0 Reboot
193 193  