Changes for page 13 HMI Internal Registers
Last modified by xingzhi lin on 2025/10/30 15:10
From version 6.5
edited by xingzhi lin
on 2025/10/30 15:10
on 2025/10/30 15:10
Change comment:
There is no comment for this version
To version 5.2
edited by xingzhi lin
on 2025/09/24 10:21
on 2025/09/24 10:21
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -134,87 +134,7 @@ 134 134 * 0: Not touching 135 135 * 1: Touching 136 136 ))) 137 -|=HUW1503|The current user's group prompt|((( 138 -A bit represents one of the groups. The administrator is bit 0, group 0 is bit 1, and group 1 is bit 2 and so on. 139 139 140 -For example: 141 - 142 -* HUW1503.0=0 (administrator) 143 -* HUW1503.1=1 (group 0) 144 -* HUW1503.2=1 (group 1) 145 -* HUW1503.3=0 (group 2) 146 - 147 -This means the current user has the permissions of groups 0 and 1, but not administrator or group 2. 148 -))) 149 -|=HSW1908|Total available user storage|Displays total available user storage (64-bit floating-point, unit: MB). 150 -|=HSW1912|Remaining available user storage|Displays remaining available user storage (64-bit floating-point, unit: MB). 151 -|=HSW1921|Touch status indicator|((( 152 -* 0: Not touching 153 -* 1: Touching 154 -))) 155 -|=HSW1923|Exclusive mode switch|((( 156 -* 0: Disable exclusive mode 157 -* 1: Enable exclusive mode 158 -))) 159 -|=HSW11773|Control auto user logout |((( 160 -Controls the enable state of auto user logout. 161 - 162 -* HSX11773.0: =0 Follow project configuration 163 -* HSX11773.0: =1 Follow address configuration 164 -* HSX11773.1: =0 Disable auto logout 165 -* HSX11773.1: =1 Enable auto logout 166 -))) 167 -|=HSW11774|Auto user logout waiting time|Sets the waiting time before automatic logout (1–255 minutes). 168 -|=((( 169 -==== **HSW11775** ==== 170 -)))|Enable NTP time synchronization|((( 171 -* 1: Enable NTP 172 -* 0: Disable NTP 173 -))) 174 -|=HSW11776|Immediate time synchronization|Perform immediate NTP sync after device startup. 175 -|=HSW11777~~11780|Primary time server IP (required when NTP is enabled)|Each register represents one byte of the IP address (high to low). 176 -|=HSW11781~~11784|Second time server IP (optional)|Each register represents one byte of the IP address (high to low). 177 -|=HSW11785~~11788|Third time server IP (optional)|Each register represents one byte of the IP address (high to low). 178 -|=HSW11789~~11792|Fourth time server IP (optional)|Each register represents one byte of the IP address (high to low). 179 -|=HSW11793|Time synchronization period|((( 180 - 181 - 182 -High byte of time synchronization period 183 -))) 184 -|=HSW11794|Time synchronization period|((( 185 - 186 - 187 -Low byte of time synchronization period 188 -))) 189 -|=HSW11795|Enable daylight saving time (DST)|((( 190 -* 1: Enable DST 191 -* 0: Disable DST 192 -))) 193 -|=HSW11796|Time adjustment|Hour adjustment 194 -|=HSW11797|Time adjustment|Minute adjustment 195 -|=HSW11798~~11807|DST start and end configuration|((( 196 -* Start month: 1–12 197 -* Week of month: 1–5 198 -* Day of week: 0–6 (0 = Sunday) 199 -* Hour: 0–23 200 -* Minute: 0–59 201 -* End month/week/day/hour/minute follow the same format. 202 -))) 203 -|=HSW11808|Whether currently in daylight saving time|((( 204 -* 1: In DST 205 -* 0: Not in DST 206 -))) 207 -|=HSW11811|Watchdog mode configuration|((( 208 -* 1: Register mode 209 -* 0: Project mode 210 -))) 211 -|=HSW11812|Enable watchdog|((( 212 -* 1: Enable 213 -* 0: Disable 214 -))) 215 -|=HSW11813|Watchdog timeout setting|Unit: second 216 -|=HSW11814|Trigger watchdog|=0 Reboot 217 - 218 218 = **Special data area (HSW/HSX)** = 219 219 220 220 It is used for system special registers (reserved by system).