Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,11 +4,11 @@ 4 4 5 5 *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address. 6 6 7 - ***System data area (HSW): **A special register defined by the system.8 - ***Data storage area (HDW/HDX): **Users store user data.9 - ***System data area (HUW): **A special register defined by the system.10 - ***System Data (HAW)**: System register used for power-off save.11 - ***Recipe index area (RPW): **System register used for recipe index.7 +1. **System data area (HSW): **A special register defined by the system. 8 +1. **Data storage area (HDW/HDX): **Users store user data. 9 +1. **System data area (HUW): **A special register defined by the system. 10 +1. **System Data (HAW)**: System register used for power-off save. 11 +1. **Recipe index area (RPW): **System register used for recipe index. 12 12 13 13 HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example). 14 14 ... ... @@ -643,22 +643,9 @@ 643 643 * =1: download firmware 644 644 * =2: enter the background 645 645 ))) 646 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 647 -* =1, delete; 648 -* = Others, do not delete 649 -))) 650 -|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)((( 651 -Monitor address is set during reset of reset switch, whether to cancel reset, 652 - 653 -* = 0, yes (default); 654 -* = 1, no 655 -))) 656 -|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)((( 657 -Controls whether the button pops up when double-clicking or long pressing on record type table object 658 - 659 -* = 0, yes (default); 660 -* = 1, no 661 -))) 646 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %) |(% style="width:452px" %) 647 +|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %) |(% style="width:452px" %)Monitor address is set during reset of reset switch, whether to cancel reset, default = 0, yes; = 1, no 648 +|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %) |(% style="width:452px" %)Controls whether the button pops up when double-clicking or long-clicking on a record-like form widget, default = 0, yes; = 1, no 662 662 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 663 663 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 664 664 **✎Note: **Only valid when the HMI is plugged into the Ethernet cable. ... ... @@ -773,10 +773,10 @@ 773 773 |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second. 774 774 |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver 775 775 776 -== Serial port communication configuration == 763 +== **Serial port communication configuration** == 777 777 778 778 (% class="table-bordered" %) 779 -|=(% s cope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**766 +|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 780 780 |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)((( 781 781 * =0: RS232 782 782 * =1: RS485 ... ... @@ -806,22 +806,10 @@ 806 806 * =1: ODD 807 807 * =2: EVEN 808 808 ))) 809 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)((( 810 -* Unit: ms. 811 -* Range: 0 to 30000 812 -))) 813 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)((( 814 -* Unit: ms. 815 -* Range: 0 to 30000 816 -))) 817 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)((( 818 -* Unit: times. 819 -* Range: 0 to 100 820 -))) 821 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)((( 822 -* Unit: s. 823 -* Range: 0 to 300 824 -))) 796 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 797 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 798 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 799 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300 825 825 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %) 826 826 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %) 827 827 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)((( ... ... @@ -854,22 +854,10 @@ 854 854 * =1: ODD 855 855 * =2: EVEN 856 856 ))) 857 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)((( 858 -* Unit: ms. 859 -* Range: 0 to 30000 860 -))) 861 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)((( 862 -* Unit: ms. 863 -* Range: 0 to 30000 864 -))) 865 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)((( 866 -* Unit: times. 867 -* Range: 0 to 100 868 -))) 869 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)((( 870 -* Unit: s. 871 -* Range: 0 to 30 872 -))) 832 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 833 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 834 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 835 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 873 873 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %) 874 874 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %) 875 875 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)((( ... ... @@ -902,22 +902,10 @@ 902 902 * =1: ODD 903 903 * =2: EVEN 904 904 ))) 905 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)((( 906 -* Unit: ms. 907 -* Range: 0 to 30000 908 -))) 909 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)((( 910 -* Unit: ms. 911 -* Range: 0 to 30000 912 -))) 913 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)((( 914 -* Unit: times. 915 -* Range: 0 to 100 916 -))) 917 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)((( 918 -* Unit: s. 919 -* Range: 0 to 30 920 -))) 868 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 869 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 870 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 871 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 921 921 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %) 922 922 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %) 923 923 |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)((( ... ... @@ -948,22 +948,10 @@ 948 948 * =1: ODD 949 949 * =2: EVEN 950 950 ))) 951 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)((( 952 -* Unit: ms. 953 -* Range: 0 to 30000 954 -))) 955 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)((( 956 -* Unit: ms. 957 -* Range: 0 to 30000 958 -))) 959 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)((( 960 -* Unit: times. 961 -* Range: 0 to 100 962 -))) 963 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)((( 964 -* Unit: s. 965 -* Range: 0 to 30 966 -))) 902 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 903 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 904 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 905 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 967 967 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %) 968 968 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %) 969 969 |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)((( ... ... @@ -994,22 +994,10 @@ 994 994 * =1: ODD 995 995 * =2: EVEN 996 996 ))) 997 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)((( 998 -* Unit: ms. 999 -* Range: 0 to 30000 1000 -))) 1001 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)((( 1002 -* Unit: ms. 1003 -* Range: 0 to 30000 1004 -))) 1005 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)((( 1006 -* Unit: times. 1007 -* Range: 0 to 100 1008 -))) 1009 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)((( 1010 -* Unit: s. 1011 -* Range: 0 to 30 1012 -))) 936 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 937 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 938 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 939 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1013 1013 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %) 1014 1014 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %) 1015 1015 |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)((( ... ... @@ -1039,37 +1039,19 @@ 1039 1039 * =1: ODD 1040 1040 * =2: EVEN 1041 1041 ))) 1042 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)((( 1043 -* Unit: ms. 1044 -* Range: 0 to 30000 1045 -))) 1046 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)((( 1047 -* Unit: ms. 1048 -* Range: 0 to 30000 1049 -))) 1050 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)((( 1051 -* Unit: times. 1052 -* Range: 0 to 100 1053 -))) 1054 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)((( 1055 -* Unit: s. 1056 -* Range: 0 to 30 1057 -))) 969 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 970 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 971 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 972 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1058 1058 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %) 1059 1059 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %) 1060 1060 |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)((( 1061 -Unit: K, the baud rate must be an integer. 1062 - 1063 -For example, when the baud rate required is 250000, just enter 250. 976 +Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1064 1064 )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect. 1065 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)((( 1066 -Unit: K, the baud rate must be an integer. 978 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1067 1067 1068 -For example, when the baud rate required is 250000, just enter 250. 1069 -))) 980 +== **Ethernet communication configuration** == 1070 1070 1071 -== Ethernet communication configuration == 1072 - 1073 1073 (% class="table-bordered" %) 1074 1074 |=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description** 1075 1075 |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1 ... ... @@ -1106,7 +1106,7 @@ 1106 1106 **✎Note:** The number of Ethernet connections supported by different HMI series varies. 1107 1107 ))) 1108 1108 1109 -== Communication control == 1018 +== **Communication control** == 1110 1110 1111 1111 (% class="table-bordered" %) 1112 1112 |=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**