Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 8.1
edited by Stone Wu
on 2022/08/25 17:27
Change comment: There is no comment for this version
To version 3.1
edited by Stone Wu
on 2022/08/03 10:03
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,11 +4,11 @@
4 4  
5 5  *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address.
6 6  
7 -* **System data area (HSW): **A special register defined by the system.
8 -* **Data storage area (HDW/HDX): **Users store user data.
9 -* **System data area (HUW): **A special register defined by the system.
10 -* **System Data (HAW)**: System register used for power-off save.
11 -* **Recipe index area (RPW): **System register used for recipe index.
7 +1. **System data area (HSW): **A special register defined by the system.
8 +1. **Data storage area (HDW/HDX): **Users store user data.
9 +1. **System data area (HUW): **A special register defined by the system.
10 +1. **System Data (HAW)**: System register used for power-off save.
11 +1. **Recipe index area (RPW): **System register used for recipe index.
12 12  
13 13  HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example).
14 14  
... ... @@ -339,11 +339,9 @@
339 339  * HDX882.1=0 SD card doesn't execute storage or storage finished.
340 340  * HDX882.1=1 SD card is reading data, don't remove SD card.
341 341  )))
342 -|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)(((
343 -* =0: Do not enter the network configuration interface
344 -* =1: Enter the system network configuration interface.
345 -** ig series HMI only supports to enter the system interface
346 -
342 +|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter setup screen|(% style="width:452px" %)(((
343 +* = 0: Do not into setup screen
344 +* = 1: Enter setup screen
347 347  )))
348 348  |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)(((
349 349  * = 0: displayed by object setting.
... ... @@ -512,10 +512,6 @@
512 512  * HSX1502.0=1: Modification comfirmed. Save the data of HSW1450~~HSW1501 to a file for immediate effect.
513 513  * HSX1502.1=1:Modification cancelled. Restore the current data of hSW1450-HSW1501 to the data saved in the file last time.
514 514  )))
515 -|=(% style="width: 160px;" %)HSW1509|(% style="width:282px" %)Curve width|(% style="width:452px" %)(((
516 -* =0: Use the curve width set by project default.
517 -* =1 to 10: use special register to set curve width.
518 -)))
519 519  |=(% style="width: 160px;" %)HSW1603|(% style="width:282px" %)Number of current unreleased alarms|(% style="width:452px" %)The number of current unreleased alarms in alarm record file.
520 520  |=(% style="width: 160px;" %)HSW1604|(% style="width:282px" %)The auxiliary judgment address when the control bit in the Object Lock fails to be read|(% style="width:452px" %)(((
521 521  * =0: The auxiliary address is invalid.
... ... @@ -643,22 +643,6 @@
643 643  * =1: download firmware
644 644  * =2: enter the background
645 645  )))
646 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
647 -* =1, delete;
648 -* = Others, do not delete
649 -)))
650 -|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
651 -Monitor address is set during reset of reset switch, whether to cancel reset,
652 -
653 -* = 0, yes (default);
654 -* = 1, no
655 -)))
656 -|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)(((
657 -Controls whether the button pops up when double-clicking or long pressing on record type table object
658 -
659 -* = 0, yes (default);
660 -* = 1, no
661 -)))
662 662  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
663 663  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
664 664  **✎Note: **Only valid when the HMI is plugged into the Ethernet cable.
... ... @@ -773,10 +773,10 @@
773 773  |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second.
774 774  |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver
775 775  
776 -== Serial port communication configuration ==
754 +== **Serial port communication configuration** ==
777 777  
778 778  (% class="table-bordered" %)
779 -|=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
757 +|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
780 780  |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)(((
781 781  * =0: RS232
782 782  * =1: RS485
... ... @@ -806,22 +806,10 @@
806 806  * =1: ODD
807 807  * =2: EVEN
808 808  )))
809 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)(((
810 -* Unit: ms.
811 -* Range: 0 to 30000
812 -)))
813 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)(((
814 -* Unit: ms.
815 -* Range: 0 to 30000
816 -)))
817 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)(((
818 -* Unit: times.
819 -* Range: 0 to 100
820 -)))
821 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)(((
822 -* Unit: s.
823 -* Range: 0 to 300
824 -)))
787 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
788 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
789 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
790 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300
825 825  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %)
826 826  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %)
827 827  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)(((
... ... @@ -854,22 +854,10 @@
854 854  * =1: ODD
855 855  * =2: EVEN
856 856  )))
857 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)(((
858 -* Unit: ms.
859 -* Range: 0 to 30000
860 -)))
861 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)(((
862 -* Unit: ms.
863 -* Range: 0 to 30000
864 -)))
865 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)(((
866 -* Unit: times.
867 -* Range: 0 to 100
868 -)))
869 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)(((
870 -* Unit: s.
871 -* Range: 0 to 30
872 -)))
823 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
824 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
825 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
826 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
873 873  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %)
874 874  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %)
875 875  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)(((
... ... @@ -902,22 +902,10 @@
902 902  * =1: ODD
903 903  * =2: EVEN
904 904  )))
905 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)(((
906 -* Unit: ms.
907 -* Range: 0 to 30000
908 -)))
909 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)(((
910 -* Unit: ms.
911 -* Range: 0 to 30000
912 -)))
913 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)(((
914 -* Unit: times.
915 -* Range: 0 to 100
916 -)))
917 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)(((
918 -* Unit: s.
919 -* Range: 0 to 30
920 -)))
859 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
860 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
861 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
862 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
921 921  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %)
922 922  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %)
923 923  |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)(((
... ... @@ -948,22 +948,10 @@
948 948  * =1: ODD
949 949  * =2: EVEN
950 950  )))
951 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)(((
952 -* Unit: ms.
953 -* Range: 0 to 30000
954 -)))
955 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)(((
956 -* Unit: ms.
957 -* Range: 0 to 30000
958 -)))
959 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)(((
960 -* Unit: times.
961 -* Range: 0 to 100
962 -)))
963 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)(((
964 -* Unit: s.
965 -* Range: 0 to 30
966 -)))
893 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
894 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
895 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
896 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
967 967  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %)
968 968  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %)
969 969  |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)(((
... ... @@ -994,22 +994,10 @@
994 994  * =1: ODD
995 995  * =2: EVEN
996 996  )))
997 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)(((
998 -* Unit: ms.
999 -* Range: 0 to 30000
1000 -)))
1001 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)(((
1002 -* Unit: ms.
1003 -* Range: 0 to 30000
1004 -)))
1005 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)(((
1006 -* Unit: times.
1007 -* Range: 0 to 100
1008 -)))
1009 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)(((
1010 -* Unit: s.
1011 -* Range: 0 to 30
1012 -)))
927 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
928 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
929 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
930 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1013 1013  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %)
1014 1014  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %)
1015 1015  |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)(((
... ... @@ -1039,48 +1039,29 @@
1039 1039  * =1: ODD
1040 1040  * =2: EVEN
1041 1041  )))
1042 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)(((
1043 -* Unit: ms.
1044 -* Range: 0 to 30000
1045 -)))
1046 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)(((
1047 -* Unit: ms.
1048 -* Range: 0 to 30000
1049 -)))
1050 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)(((
1051 -* Unit: times.
1052 -* Range: 0 to 100
1053 -)))
1054 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)(((
1055 -* Unit: s.
1056 -* Range: 0 to 30
1057 -)))
960 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
961 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
962 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
963 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1058 1058  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %)
1059 1059  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %)
1060 1060  |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)(((
1061 -Unit: K, the baud rate must be an integer.
1062 -
1063 -For example, when the baud rate required is 250000, just enter 250.
967 +Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1064 1064  )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect.
1065 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)(((
1066 -Unit: K, the baud rate must be an integer.
969 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1067 1067  
1068 -For example, when the baud rate required is 250000, just enter 250.
1069 -)))
971 +== **Ethernet communication configuration** ==
1070 1070  
1071 -== Ethernet communication configuration ==
1072 -
1073 1073  (% class="table-bordered" %)
1074 -|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description**
974 +|=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description**
1075 1075  |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1
1076 1076  |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2
1077 1077  |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3
1078 1078  |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4
1079 1079  |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number
1080 -|(% style="width:220px" %)HSW11009|(% style="width:336px" %)(((
1081 -~=2 TCP
1082 -
1083 -~=3 UDP
980 +|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)(((
981 +* =2 TCP
982 +* =3 UDP
1084 1084  )))
1085 1085  |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved
1086 1086  |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1
... ... @@ -1088,10 +1088,9 @@
1088 1088  |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3
1089 1089  |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4
1090 1090  |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number
1091 -|(% style="width:220px" %)HSW11016|(% style="width:336px" %)(((
1092 -~=2 TCP
1093 -
1094 -~=3 UDP
990 +|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)(((
991 +* =2 TCP
992 +* =3 UDP
1095 1095  )))
1096 1096  |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved
1097 1097  |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)…
... ... @@ -1100,11 +1100,7 @@
1100 1100  |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3
1101 1101  |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4
1102 1102  |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number
1103 -|(% style="width:220px" %)HSW11226|(% style="width:336px" %)(((
1104 -~=2 TCP;
1105 -
1106 -~=3 UDP
1107 -)))
1001 +|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP
1108 1108  |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved
1109 1109  
1110 1110  (% class="box infomessage" %)
... ... @@ -1112,10 +1112,10 @@
1112 1112  **✎Note:** The number of Ethernet connections supported by different HMI series varies.
1113 1113  )))
1114 1114  
1115 -== Communication control ==
1009 +== **Communication control** ==
1116 1116  
1117 1117  (% class="table-bordered" %)
1118 -|=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**
1012 +|(% style="width:135px" %)**Communication No.**|(% style="width:102px" %)**Station No.**|(% style="width:185px" %)**Control bit**|(% style="width:191px" %)**Communication lamp**|(% style="width:271px" %)**Description**
1119 1119  |(% colspan="1" rowspan="16" style="width:135px" %)1|(% style="width:102px" %)0~~15|(% style="width:185px" %)HSX550.0~HSX550.15|(% style="width:191px" %)HSX558.0~HSX558.15|(% rowspan="160" style="width:271px" %)Communication number refers to the number in "Communication Port Configuration". A number provides 256 device station numbers. Each station number corresponds to a communication control bit and a communication indicator bit. Registers HSX550.0 to HSX805.15 are used to control the station numbers from 0 to 127, and registers HSX1150.0 to HSX1405.15 are used to control station numbers 128 to 255.
1120 1120  |(% style="width:102px" %)16~~31|(% style="width:185px" %)HSX551.0~HSX551.15|(% style="width:191px" %)HSX559.0~HSX559.15
1121 1121  |(% style="width:102px" %)32~~47|(% style="width:185px" %)HSX552.0~HSX552.15|(% style="width:191px" %)HSX560.0~HSX560.15