Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,11 +4,11 @@ 4 4 5 5 *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address. 6 6 7 - ***System data area (HSW): **A special register defined by the system.8 - ***Data storage area (HDW/HDX): **Users store user data.9 - ***System data area (HUW): **A special register defined by the system.10 - ***System Data (HAW)**: System register used for power-off save.11 - ***Recipe index area (RPW): **System register used for recipe index.7 +1. **System data area (HSW): **A special register defined by the system. 8 +1. **Data storage area (HDW/HDX): **Users store user data. 9 +1. **System data area (HUW): **A special register defined by the system. 10 +1. **System Data (HAW)**: System register used for power-off save. 11 +1. **Recipe index area (RPW): **System register used for recipe index. 12 12 13 13 HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example). 14 14 ... ... @@ -339,11 +339,9 @@ 339 339 * HDX882.1=0 SD card doesn't execute storage or storage finished. 340 340 * HDX882.1=1 SD card is reading data, don't remove SD card. 341 341 ))) 342 -|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)((( 343 -* =0: Do not enter the network configuration interface 344 -* =1: Enter the system network configuration interface. 345 -** ig series HMI only supports to enter the system interface 346 - 342 +|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter setup screen|(% style="width:452px" %)((( 343 +* = 0: Do not into setup screen 344 +* = 1: Enter setup screen 347 347 ))) 348 348 |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)((( 349 349 * = 0: displayed by object setting. ... ... @@ -512,10 +512,6 @@ 512 512 * HSX1502.0=1: Modification comfirmed. Save the data of HSW1450~~HSW1501 to a file for immediate effect. 513 513 * HSX1502.1=1:Modification cancelled. Restore the current data of hSW1450-HSW1501 to the data saved in the file last time. 514 514 ))) 515 -|=(% style="width: 160px;" %)HSW1509|(% style="width:282px" %)Curve width|(% style="width:452px" %)((( 516 -* =0: Use the curve width set by project default. 517 -* =1 to 10: use special register to set curve width. 518 -))) 519 519 |=(% style="width: 160px;" %)HSW1603|(% style="width:282px" %)Number of current unreleased alarms|(% style="width:452px" %)The number of current unreleased alarms in alarm record file. 520 520 |=(% style="width: 160px;" %)HSW1604|(% style="width:282px" %)The auxiliary judgment address when the control bit in the Object Lock fails to be read|(% style="width:452px" %)((( 521 521 * =0: The auxiliary address is invalid. ... ... @@ -643,22 +643,6 @@ 643 643 * =1: download firmware 644 644 * =2: enter the background 645 645 ))) 646 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 647 -* =1, delete; 648 -* = Others, do not delete 649 -))) 650 -|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)((( 651 -Monitor address is set during reset of reset switch, whether to cancel reset, 652 - 653 -* = 0, yes (default); 654 -* = 1, no 655 -))) 656 -|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)((( 657 -Controls whether the button pops up when double-clicking or long pressing on record type table object 658 - 659 -* = 0, yes (default); 660 -* = 1, no 661 -))) 662 662 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 663 663 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 664 664 **✎Note: **Only valid when the HMI is plugged into the Ethernet cable. ... ... @@ -773,10 +773,10 @@ 773 773 |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second. 774 774 |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver 775 775 776 -== Serial port communication configuration == 754 +== **Serial port communication configuration** == 777 777 778 778 (% class="table-bordered" %) 779 -|=(% s cope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**757 +|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 780 780 |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)((( 781 781 * =0: RS232 782 782 * =1: RS485 ... ... @@ -806,22 +806,10 @@ 806 806 * =1: ODD 807 807 * =2: EVEN 808 808 ))) 809 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)((( 810 -* Unit: ms. 811 -* Range: 0 to 30000 812 -))) 813 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)((( 814 -* Unit: ms. 815 -* Range: 0 to 30000 816 -))) 817 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)((( 818 -* Unit: times. 819 -* Range: 0 to 100 820 -))) 821 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)((( 822 -* Unit: s. 823 -* Range: 0 to 300 824 -))) 787 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 788 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 789 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 790 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300 825 825 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %) 826 826 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %) 827 827 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)((( ... ... @@ -854,22 +854,10 @@ 854 854 * =1: ODD 855 855 * =2: EVEN 856 856 ))) 857 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)((( 858 -* Unit: ms. 859 -* Range: 0 to 30000 860 -))) 861 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)((( 862 -* Unit: ms. 863 -* Range: 0 to 30000 864 -))) 865 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)((( 866 -* Unit: times. 867 -* Range: 0 to 100 868 -))) 869 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)((( 870 -* Unit: s. 871 -* Range: 0 to 30 872 -))) 823 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 824 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 825 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 826 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 873 873 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %) 874 874 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %) 875 875 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)((( ... ... @@ -902,22 +902,10 @@ 902 902 * =1: ODD 903 903 * =2: EVEN 904 904 ))) 905 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)((( 906 -* Unit: ms. 907 -* Range: 0 to 30000 908 -))) 909 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)((( 910 -* Unit: ms. 911 -* Range: 0 to 30000 912 -))) 913 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)((( 914 -* Unit: times. 915 -* Range: 0 to 100 916 -))) 917 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)((( 918 -* Unit: s. 919 -* Range: 0 to 30 920 -))) 859 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 860 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 861 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 862 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 921 921 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %) 922 922 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %) 923 923 |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)((( ... ... @@ -948,22 +948,10 @@ 948 948 * =1: ODD 949 949 * =2: EVEN 950 950 ))) 951 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)((( 952 -* Unit: ms. 953 -* Range: 0 to 30000 954 -))) 955 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)((( 956 -* Unit: ms. 957 -* Range: 0 to 30000 958 -))) 959 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)((( 960 -* Unit: times. 961 -* Range: 0 to 100 962 -))) 963 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)((( 964 -* Unit: s. 965 -* Range: 0 to 30 966 -))) 893 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 894 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 895 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 896 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 967 967 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %) 968 968 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %) 969 969 |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)((( ... ... @@ -994,22 +994,10 @@ 994 994 * =1: ODD 995 995 * =2: EVEN 996 996 ))) 997 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)((( 998 -* Unit: ms. 999 -* Range: 0 to 30000 1000 -))) 1001 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)((( 1002 -* Unit: ms. 1003 -* Range: 0 to 30000 1004 -))) 1005 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)((( 1006 -* Unit: times. 1007 -* Range: 0 to 100 1008 -))) 1009 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)((( 1010 -* Unit: s. 1011 -* Range: 0 to 30 1012 -))) 927 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 928 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 929 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 930 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1013 1013 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %) 1014 1014 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %) 1015 1015 |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)((( ... ... @@ -1039,48 +1039,29 @@ 1039 1039 * =1: ODD 1040 1040 * =2: EVEN 1041 1041 ))) 1042 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)((( 1043 -* Unit: ms. 1044 -* Range: 0 to 30000 1045 -))) 1046 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)((( 1047 -* Unit: ms. 1048 -* Range: 0 to 30000 1049 -))) 1050 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)((( 1051 -* Unit: times. 1052 -* Range: 0 to 100 1053 -))) 1054 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)((( 1055 -* Unit: s. 1056 -* Range: 0 to 30 1057 -))) 960 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 961 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 962 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 963 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1058 1058 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %) 1059 1059 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %) 1060 1060 |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)((( 1061 -Unit: K, the baud rate must be an integer. 1062 - 1063 -For example, when the baud rate required is 250000, just enter 250. 967 +Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1064 1064 )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect. 1065 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)((( 1066 -Unit: K, the baud rate must be an integer. 969 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1067 1067 1068 -For example, when the baud rate required is 250000, just enter 250. 1069 -))) 971 +== **Ethernet communication configuration** == 1070 1070 1071 -== Ethernet communication configuration == 1072 - 1073 1073 (% class="table-bordered" %) 1074 -|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description** 974 +|=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description** 1075 1075 |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1 1076 1076 |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2 1077 1077 |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3 1078 1078 |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4 1079 1079 |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number 1080 -|(% style="width:220px" %)HSW11009|(% style="width:336px" %)((( 1081 -~=2 TCP 1082 - 1083 -~=3 UDP 980 +|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)((( 981 +* =2 TCP 982 +* =3 UDP 1084 1084 ))) 1085 1085 |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved 1086 1086 |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1 ... ... @@ -1088,10 +1088,9 @@ 1088 1088 |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3 1089 1089 |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4 1090 1090 |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number 1091 -|(% style="width:220px" %)HSW11016|(% style="width:336px" %)((( 1092 -~=2 TCP 1093 - 1094 -~=3 UDP 990 +|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)((( 991 +* =2 TCP 992 +* =3 UDP 1095 1095 ))) 1096 1096 |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved 1097 1097 |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)… ... ... @@ -1100,11 +1100,7 @@ 1100 1100 |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3 1101 1101 |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4 1102 1102 |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number 1103 -|(% style="width:220px" %)HSW11226|(% style="width:336px" %)((( 1104 -~=2 TCP; 1105 - 1106 -~=3 UDP 1107 -))) 1001 +|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP 1108 1108 |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved 1109 1109 1110 1110 (% class="box infomessage" %) ... ... @@ -1112,10 +1112,10 @@ 1112 1112 **✎Note:** The number of Ethernet connections supported by different HMI series varies. 1113 1113 ))) 1114 1114 1115 -== Communication control == 1009 +== **Communication control** == 1116 1116 1117 1117 (% class="table-bordered" %) 1118 -| =(% style="width:;" %)**Communication No.**|=(% style="width:;" %)**Station No.**|=(% style="width:;" %)**Control bit**|=(% style="width:;" %)**Communication lamp**|=(% style="width:;" %)**Description**1012 +|(% style="width:135px" %)**Communication No.**|(% style="width:102px" %)**Station No.**|(% style="width:185px" %)**Control bit**|(% style="width:191px" %)**Communication lamp**|(% style="width:271px" %)**Description** 1119 1119 |(% colspan="1" rowspan="16" style="width:135px" %)1|(% style="width:102px" %)0~~15|(% style="width:185px" %)HSX550.0~HSX550.15|(% style="width:191px" %)HSX558.0~HSX558.15|(% rowspan="160" style="width:271px" %)Communication number refers to the number in "Communication Port Configuration". A number provides 256 device station numbers. Each station number corresponds to a communication control bit and a communication indicator bit. Registers HSX550.0 to HSX805.15 are used to control the station numbers from 0 to 127, and registers HSX1150.0 to HSX1405.15 are used to control station numbers 128 to 255. 1120 1120 |(% style="width:102px" %)16~~31|(% style="width:185px" %)HSX551.0~HSX551.15|(% style="width:191px" %)HSX559.0~HSX559.15 1121 1121 |(% style="width:102px" %)32~~47|(% style="width:185px" %)HSX552.0~HSX552.15|(% style="width:191px" %)HSX560.0~HSX560.15