Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 8.1
edited by Stone Wu
on 2022/08/25 17:27
Change comment: There is no comment for this version
To version 6.1
edited by Stone Wu
on 2022/08/06 14:29
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,11 +4,11 @@
4 4  
5 5  *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address.
6 6  
7 -* **System data area (HSW): **A special register defined by the system.
8 -* **Data storage area (HDW/HDX): **Users store user data.
9 -* **System data area (HUW): **A special register defined by the system.
10 -* **System Data (HAW)**: System register used for power-off save.
11 -* **Recipe index area (RPW): **System register used for recipe index.
7 +1. **System data area (HSW): **A special register defined by the system.
8 +1. **Data storage area (HDW/HDX): **Users store user data.
9 +1. **System data area (HUW): **A special register defined by the system.
10 +1. **System Data (HAW)**: System register used for power-off save.
11 +1. **Recipe index area (RPW): **System register used for recipe index.
12 12  
13 13  HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example).
14 14  
... ... @@ -773,7 +773,7 @@
773 773  |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second.
774 774  |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver
775 775  
776 -== Serial port communication configuration ==
776 +== **Serial port communication configuration** ==
777 777  
778 778  (% class="table-bordered" %)
779 779  |=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
... ... @@ -1068,19 +1068,18 @@
1068 1068  For example, when the baud rate required is 250000, just enter 250.
1069 1069  )))
1070 1070  
1071 -== Ethernet communication configuration ==
1071 +== **Ethernet communication configuration** ==
1072 1072  
1073 1073  (% class="table-bordered" %)
1074 -|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description**
1074 +|=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description**
1075 1075  |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1
1076 1076  |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2
1077 1077  |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3
1078 1078  |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4
1079 1079  |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number
1080 -|(% style="width:220px" %)HSW11009|(% style="width:336px" %)(((
1081 -~=2 TCP
1082 -
1083 -~=3 UDP
1080 +|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)(((
1081 +* =2 TCP
1082 +* =3 UDP
1084 1084  )))
1085 1085  |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved
1086 1086  |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1
... ... @@ -1088,10 +1088,9 @@
1088 1088  |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3
1089 1089  |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4
1090 1090  |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number
1091 -|(% style="width:220px" %)HSW11016|(% style="width:336px" %)(((
1092 -~=2 TCP
1093 -
1094 -~=3 UDP
1090 +|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)(((
1091 +* =2 TCP
1092 +* =3 UDP
1095 1095  )))
1096 1096  |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved
1097 1097  |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)…
... ... @@ -1100,11 +1100,7 @@
1100 1100  |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3
1101 1101  |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4
1102 1102  |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number
1103 -|(% style="width:220px" %)HSW11226|(% style="width:336px" %)(((
1104 -~=2 TCP;
1105 -
1106 -~=3 UDP
1107 -)))
1101 +|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP
1108 1108  |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved
1109 1109  
1110 1110  (% class="box infomessage" %)
... ... @@ -1112,7 +1112,7 @@
1112 1112  **✎Note:** The number of Ethernet connections supported by different HMI series varies.
1113 1113  )))
1114 1114  
1115 -== Communication control ==
1109 +== **Communication control** ==
1116 1116  
1117 1117  (% class="table-bordered" %)