Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 9.2
edited by Theodore Xu
on 2022/12/16 10:09
Change comment: There is no comment for this version
To version 4.2
edited by Stone Wu
on 2022/08/06 14:08
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.AiXia
1 +XWiki.Stone
Content
... ... @@ -4,11 +4,11 @@
4 4  
5 5  *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address.
6 6  
7 -* **System data area (HSW): **A special register defined by the system.
8 -* **Data storage area (HDW/HDX): **Users store user data.
9 -* **System data area (HUW): **A special register defined by the system.
10 -* **System Data (HAW)**: System register used for power-off save.
11 -* **Recipe index area (RPW): **System register used for recipe index.
7 +1. **System data area (HSW): **A special register defined by the system.
8 +1. **Data storage area (HDW/HDX): **Users store user data.
9 +1. **System data area (HUW): **A special register defined by the system.
10 +1. **System Data (HAW)**: System register used for power-off save.
11 +1. **Recipe index area (RPW): **System register used for recipe index.
12 12  
13 13  HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example).
14 14  
... ... @@ -342,7 +342,7 @@
342 342  |=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)(((
343 343  * =0: Do not enter the network configuration interface
344 344  * =1: Enter the system network configuration interface.
345 -** ig series HMI only supports to enter the system interface
345 +** (ig series HMI only supports to enter the system interface)
346 346  
347 347  )))
348 348  |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)(((
... ... @@ -512,10 +512,6 @@
512 512  * HSX1502.0=1: Modification comfirmed. Save the data of HSW1450~~HSW1501 to a file for immediate effect.
513 513  * HSX1502.1=1:Modification cancelled. Restore the current data of hSW1450-HSW1501 to the data saved in the file last time.
514 514  )))
515 -|=(% style="width: 160px;" %)HSW1509|(% style="width:282px" %)Curve width|(% style="width:452px" %)(((
516 -* =0: Use the curve width set by project default.
517 -* =1 to 10: use special register to set curve width.
518 -)))
519 519  |=(% style="width: 160px;" %)HSW1603|(% style="width:282px" %)Number of current unreleased alarms|(% style="width:452px" %)The number of current unreleased alarms in alarm record file.
520 520  |=(% style="width: 160px;" %)HSW1604|(% style="width:282px" %)The auxiliary judgment address when the control bit in the Object Lock fails to be read|(% style="width:452px" %)(((
521 521  * =0: The auxiliary address is invalid.
... ... @@ -643,27 +643,6 @@
643 643  * =1: download firmware
644 644  * =2: enter the background
645 645  )))
646 -|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)(((
647 -* =0: priority  Ethernet
648 -* =1: priority WLAN
649 -* =2: priority 4G
650 -)))
651 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
652 -* =0: delete;
653 -* = Others: do not delete
654 -)))
655 -|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
656 -Monitor address is set during reset of reset switch, whether to cancel reset,
657 -
658 -* = 0: yes (default);
659 -* = 1: no
660 -)))
661 -|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)(((
662 -Controls whether the button pops up when double-clicking or long pressing on record type table object
663 -
664 -* = 0: yes (default);
665 -* = 1: no
666 -)))
667 667  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
668 668  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
669 669  **✎Note: **Only valid when the HMI is plugged into the Ethernet cable.
... ... @@ -778,10 +778,10 @@
778 778  |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second.
779 779  |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver
780 780  
781 -== Serial port communication configuration ==
756 +== **Serial port communication configuration** ==
782 782  
783 783  (% class="table-bordered" %)
784 -|=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
759 +|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
785 785  |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)(((
786 786  * =0: RS232
787 787  * =1: RS485
... ... @@ -811,22 +811,10 @@
811 811  * =1: ODD
812 812  * =2: EVEN
813 813  )))
814 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)(((
815 -* Unit: ms.
816 -* Range: 0 to 30000
817 -)))
818 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)(((
819 -* Unit: ms.
820 -* Range: 0 to 30000
821 -)))
822 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)(((
823 -* Unit: times.
824 -* Range: 0 to 100
825 -)))
826 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)(((
827 -* Unit: s.
828 -* Range: 0 to 300
829 -)))
789 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
790 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
791 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
792 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300
830 830  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %)
831 831  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %)
832 832  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)(((
... ... @@ -859,22 +859,10 @@
859 859  * =1: ODD
860 860  * =2: EVEN
861 861  )))
862 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)(((
863 -* Unit: ms.
864 -* Range: 0 to 30000
865 -)))
866 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)(((
867 -* Unit: ms.
868 -* Range: 0 to 30000
869 -)))
870 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)(((
871 -* Unit: times.
872 -* Range: 0 to 100
873 -)))
874 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)(((
875 -* Unit: s.
876 -* Range: 0 to 30
877 -)))
825 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
826 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
827 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
828 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
878 878  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %)
879 879  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %)
880 880  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)(((
... ... @@ -907,22 +907,10 @@
907 907  * =1: ODD
908 908  * =2: EVEN
909 909  )))
910 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)(((
911 -* Unit: ms.
912 -* Range: 0 to 30000
913 -)))
914 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)(((
915 -* Unit: ms.
916 -* Range: 0 to 30000
917 -)))
918 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)(((
919 -* Unit: times.
920 -* Range: 0 to 100
921 -)))
922 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)(((
923 -* Unit: s.
924 -* Range: 0 to 30
925 -)))
861 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
862 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
863 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
864 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
926 926  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %)
927 927  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %)
928 928  |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)(((
... ... @@ -953,22 +953,10 @@
953 953  * =1: ODD
954 954  * =2: EVEN
955 955  )))
956 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)(((
957 -* Unit: ms.
958 -* Range: 0 to 30000
959 -)))
960 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)(((
961 -* Unit: ms.
962 -* Range: 0 to 30000
963 -)))
964 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)(((
965 -* Unit: times.
966 -* Range: 0 to 100
967 -)))
968 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)(((
969 -* Unit: s.
970 -* Range: 0 to 30
971 -)))
895 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
896 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
897 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
898 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
972 972  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %)
973 973  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %)
974 974  |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)(((
... ... @@ -999,22 +999,10 @@
999 999  * =1: ODD
1000 1000  * =2: EVEN
1001 1001  )))
1002 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)(((
1003 -* Unit: ms.
1004 -* Range: 0 to 30000
1005 -)))
1006 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)(((
1007 -* Unit: ms.
1008 -* Range: 0 to 30000
1009 -)))
1010 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)(((
1011 -* Unit: times.
1012 -* Range: 0 to 100
1013 -)))
1014 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)(((
1015 -* Unit: s.
1016 -* Range: 0 to 30
1017 -)))
929 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
930 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
931 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
932 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1018 1018  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %)
1019 1019  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %)
1020 1020  |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)(((
... ... @@ -1044,48 +1044,29 @@
1044 1044  * =1: ODD
1045 1045  * =2: EVEN
1046 1046  )))
1047 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)(((
1048 -* Unit: ms.
1049 -* Range: 0 to 30000
1050 -)))
1051 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)(((
1052 -* Unit: ms.
1053 -* Range: 0 to 30000
1054 -)))
1055 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)(((
1056 -* Unit: times.
1057 -* Range: 0 to 100
1058 -)))
1059 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)(((
1060 -* Unit: s.
1061 -* Range: 0 to 30
1062 -)))
962 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
963 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
964 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
965 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1063 1063  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %)
1064 1064  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %)
1065 1065  |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)(((
1066 -Unit: K, the baud rate must be an integer.
1067 -
1068 -For example, when the baud rate required is 250000, just enter 250.
969 +Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1069 1069  )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect.
1070 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)(((
1071 -Unit: K, the baud rate must be an integer.
971 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1072 1072  
1073 -For example, when the baud rate required is 250000, just enter 250.
1074 -)))
973 +== **Ethernet communication configuration** ==
1075 1075  
1076 -== Ethernet communication configuration ==
1077 -
1078 1078  (% class="table-bordered" %)
1079 -|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description**
976 +|=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description**
1080 1080  |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1
1081 1081  |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2
1082 1082  |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3
1083 1083  |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4
1084 1084  |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number
1085 -|(% style="width:220px" %)HSW11009|(% style="width:336px" %)(((
1086 -~=2 TCP
1087 -
1088 -~=3 UDP
982 +|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)(((
983 +* =2 TCP
984 +* =3 UDP
1089 1089  )))
1090 1090  |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved
1091 1091  |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1
... ... @@ -1093,10 +1093,9 @@
1093 1093  |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3
1094 1094  |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4
1095 1095  |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number
1096 -|(% style="width:220px" %)HSW11016|(% style="width:336px" %)(((
1097 -~=2 TCP
1098 -
1099 -~=3 UDP
992 +|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)(((
993 +* =2 TCP
994 +* =3 UDP
1100 1100  )))
1101 1101  |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved
1102 1102  |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)…
... ... @@ -1105,11 +1105,7 @@
1105 1105  |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3
1106 1106  |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4
1107 1107  |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number
1108 -|(% style="width:220px" %)HSW11226|(% style="width:336px" %)(((
1109 -~=2 TCP;
1110 -
1111 -~=3 UDP
1112 -)))
1003 +|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP
1113 1113  |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved
1114 1114  
1115 1115  (% class="box infomessage" %)
... ... @@ -1117,7 +1117,7 @@
1117 1117  **✎Note:** The number of Ethernet connections supported by different HMI series varies.
1118 1118  )))
1119 1119  
1120 -== Communication control ==
1011 +== **Communication control** ==
1121 1121  
1122 1122  (% class="table-bordered" %)
1123 1123  |=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**