Wiki source code of 13 HMI Internal Registers

Version 6.4 by xingzhi lin on 2025/10/30 15:03

Show last authors
1 = **Introduction** =
2
3 HMI provide four types of HMI address for user. You can use them as temporary variables of the program. The use is consistent with the way access to the PLC register. You could also reference through the address, PIStudio provides three types of such memory.
4
5 *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address.
6
7 * **System data area (HSW): **A special register defined by the system.
8 * **Data storage area (HDW/HDX): **Users store user data.
9 * **System data area (HUW): **A special register defined by the system.
10 * **System Data (HAW)**: System register used for power-off save.
11 * **Recipe index area (RPW): **System register used for recipe index.
12
13 HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example).
14
15 * Access as word with the prefix "HDW".
16 ** HDW0 means the 1st word of system data area. HDW1 means the 2nd word of system data area.
17 * Access as bit with the prefix "HDX".  The number before "." i".  The number before Access in bit with the prefix "HD".  The number before Access in bit with the prefix "HDX". The number before "." indicates the number of the word. The number after "." indicates the bit number of the word.
18 ** HDX1020.12 means to access the system data area in bit mode, the specific location is the 13th bit of the 1020 word.
19
20 (% class="box infomessage" %)
21 (((
22 **✎Note:**
23
24 * Addresses in HDX are the bits from words in HDW, so be careful when using addresses. For example, HDX1020.12 is the 13th bit to access the 1020 word. The value of this bit is the same as that of the word accessed through HDW001020. The 13th bit of this word is actually the same bit as HDX1020.12.
25 * The address of the bit address HDX is with a decimal point while word addresses are integers.
26 )))
27
28 = Address ranges table =
29
30 (% style="text-align:center" %)
31 [[image:6.png]]
32
33 = **Data storage area (HDW/HDX)** =
34
35 It is used to save the temporary data of project.
36
37 1. Access as word, and serial number range is from HDW0 to HDW299999.
38 1. Access as bit, and serial number range is from HDX0.0 to HDX299999.15.
39
40 = **Power-down save area (HAW/HAX)** =
41
42 It is system registers used for power-off save.
43
44 1. Access as word, and serial number range is from HAW0 to HAW199999.
45 1. Access as bit, and serial number range is from HAX0.0 to HAX199999.15.
46
47 (% class="box infomessage" %)
48 (((
49 **✎Note:**
50
51 * HAW/HAX is power-down retention. The register of this type is able to save the data before the power-down.
52 * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre
53 )))
54
55 = **Recipe index area (RPW)** =
56
57 It is system recipe data power-off save register. The range is from RPW000000 to RPW990450.
58
59 (% class="box infomessage" %)
60 (((
61 **✎Note:**
62
63 * RPW is power-down retention. The register of this type is able to save the data before the power-down.
64 * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre
65 )))
66
67 = **Single user data area (HUW/HUX)** =
68
69 It is used for system special registers (reserved by system).
70
71 1. Access as word, and serial number range is from HUW0 to HUW1599.
72 1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15.
73
74 (% class="box infomessage" %)
75 (((
76 **✎Note:**
77
78 * HUW/HUX is a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table.
79 )))
80
81 (% class="table-bordered" %)
82 |=**Special register address**|=**Description**|=**Function**
83 |=HUW0|Screen switch|A single terminal controls the screen switching, and all terminals do not affect each other.
84 |=HUW110~~HUW119|(% rowspan="26" %)Addresses of the built-in keyboard|The T9 input method stores the selected seria number length
85 |=HUW120~~HUW129|The T9 input method stores the selected Chinese Pinyin length
86 |=HUW135|Input method: first input
87 |=HUW136|Button: T9 Chinese Pinyin page
88 |=HUW137|Button: T9 Chinese characters page
89 |=HUW138|Button: symbol
90 |=HUW139|Button: switch
91 |=HUW140|Button: Chinese characters 1
92 |=HUW142|Button: Chinese characters 2
93 |=HUW144|Button: Chinese characters 3
94 |=HUW146|Button: Chinese characters 4
95 |=HUW148|Button: Chinese characters 5
96 |=HUW150|Button: Chinese characters 6
97 |=HUW152|Button: Chinese characters 7
98 |=HUW154|Button: Chinese characters 8
99 |=HUW156|Button: Chinese characters 9
100 |=HUW158|Button: Chinese characters 10
101 |=HUW160~~HUW169|Button: Chinese Pinyin 1
102 |=HUW170~~HUW179|Button: Chinese Pinyin 2
103 |=HUW180~~HUW189|Button: Chinese Pinyin 3
104 |=HUW190~~HUW199|Button: Chinese Pinyin 4
105 |=HUW200~~HUW699|Input method cache length
106 |=HUW700~~HUW749|Minimum value of the input method
107 |=HUW750~~HUW799|Maximum value of the input method
108 |=HUW800|Case switching of the input method
109 |=HUW801~~HUW900|Input method format cache length
110 |=HUW1000|(% rowspan="12" %)Addresses of user permission|OK (Sign in)
111 |=HUW1001|Result of operation
112 |=HUW1002~~1005|Old password
113 |=HUW1006~~1009|New password
114 |=HUW1010~~1013|Confirm password
115 |=HUW1014~~1029|New user name
116 |=HUW1030~~1157|States information of user permission
117 |=HUW1158~~1335|User name (Only or drop-down list object)
118 |=HUW1336~~1345|User name description or note
119 |=HUW1347|Hidden function configurations
120 |=HUW1348|Permission settings
121 |=HUW1349|Current user name
122 |=HUW1382|User sign in way|(((
123 * 0: Select the user name from drop-down list object for signing in
124 * 1: Enter the user name in Character Input/Display object for signing in (HUW1014)
125 )))
126 |=HUW1400|Time interval from last operation|(((
127 Shows how long the touch screen has not been clicked, in seconds. 32-bit unsigned integer
128
129 **✎Note:** Clicking by different users will only clear the corresponding register of the currently operating terminal, and the registers on other terminals (such as mobile phones, computers) will not be cleared.
130 )))
131 |=HUW1402|Keyboard note|It saves the text information of the keyboard notes when clicking object(HUW1402-HUW1433)
132 |=HUW1436|Current object level|Indicate current object security level
133 |=HUW1502|Touch status prompt|(((
134 * 0: Not touching
135 * 1: Touching
136 )))
137 |=HUW1503|The current user's group prompt|(((
138 A bit represents one of the groups. The administrator is bit 0, group 0 is bit 1, and group 1 is bit 2 and so on.
139
140 For example:
141
142 * HUW1503.0=0 (administrator)
143 * HUW1503.1=1 (group 0)
144 * HUW1503.2=1 (group 1)
145 * HUW1503.3=0 (group 2)
146
147 This means the current user has the permissions of groups 0 and 1, but not administrator or group 2.
148 )))
149 |=HSW1908|Total available user storage|Displays total available user storage (64-bit floating-point, unit: MB).
150 |=HSW1912|Remaining available user storage|Displays remaining available user storage (64-bit floating-point, unit: MB).
151 |=HSW1921|Touch status indicator|(((
152 * 0: Not touching
153 * 1: Touching
154 )))
155 |=HSW1923|Exclusive mode switch|(((
156 * 0: Disable exclusive mode
157 * 1: Enable exclusive mode
158 )))
159 |=HSW11773|Control auto user logout |(((
160 Controls the enable state of auto user logout.
161
162 * HSX11773.0: =0 Follow project configuration
163 * HSX11773.0: =1 Follow address configuration
164 * HSX11773.1: =0 Disable auto logout
165 * HSX11773.1: =1 Enable auto logout
166 )))
167 |=HSW11774|Auto user logout waiting time|Sets the waiting time before automatic logout (1–255 minutes).
168 |=(((
169 ==== **HSW11775** ====
170 )))|Enable NTP time synchronization|(((
171 * 1: Enable NTP
172 * 0: Disable NTP
173 )))
174 |=HSW11776|Immediate time synchronization|Perform immediate NTP sync after device startup.
175 |=HSW11777~~11780|Primary time server IP (required when NTP is enabled)|Each register represents one byte of the IP address (high to low).
176 |=HSW11781~~11784|Second time server IP (optional)|Each register represents one byte of the IP address (high to low).
177 |=HSW11785~~11788|Third time server IP (optional)|Each register represents one byte of the IP address (high to low).
178 |=HSW11789~~11792|Fourth time server IP (optional)|Each register represents one byte of the IP address (high to low).
179 |=HSW11793|Time synchronization period|(((
180
181
182 High byte of time synchronization period
183 )))
184 |=HSW11794|Time synchronization period|(((
185
186
187 Low byte of time synchronization period
188 )))
189 |=HSW11795|Enable daylight saving time (DST)|(((
190 * 1: Enable DST
191 * 0: Disable DST
192 )))
193 |=HSW11796|Time adjustment|Hour adjustment
194 |=HSW11797|Time adjustment|Minute adjustment
195
196 = **Special data area (HSW/HSX)** =
197
198 It is used for system special registers (reserved by system).
199
200 1. Access as word, and serial number range is from HSW0 to HSW49999. (HSW10000 to HSW19999 are the power-off storage areas)
201 1. Access as bit, and serial number range is from HSX0.0 to HSX49999.15.
202
203 (% class="box infomessage" %)
204 (((
205 **✎Note:**
206
207 * HSW / HSX are a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table.
208 * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save address.
209 )))
210
211 (% class="table-bordered" style="margin-left:auto; margin-right:auto; width:1024px" %)
212 |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description**
213 |=(% style="width: 160px;" %)HSW0|(% style="width:282px" %)Language switch|(% style="width:452px" %)Multiple language could be set in the project, HMI support maximum 8 languages. (Power-down save supported)
214 |=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency (Only valid in HMI V1.0 System)|(% style="width:452px" %)Frequency range: 0~~4000
215 |=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume (Only valid in HMI V1.0 System)|(% style="width:452px" %)Volume range: 0~~80
216 |=(% style="width: 160px;" %)HSW3|(% style="width:282px" %)Beep time|(% style="width:452px" %)Unit: ms
217 |=(% style="width: 160px;" %)HSW4|(% style="width:282px" %)Beep whether enable or not|(% style="width:452px" %)(((
218 * =0: Enable.
219 * =1: Disable.
220 )))
221 |=(% style="width: 160px;" %)HSW5|(% style="width:282px" %)(((
222 Alarm indicator
223 )))|(% style="width:452px" %)(((
224 * =0: Currently no alarm or all alarms have been off.
225 * =1: Currently alarm(s) still keep in on.
226 )))
227 |=(% style="width: 160px;" %)HSW6~~HSW7|(% style="width:282px" %)Number of alarms|(% style="width:452px" %)The number of alarm (it also includes the records of alarm confirmed)
228 |=(% style="width: 160px;" %)HSW8|(% style="width:282px" %)Number of unconfirmed history alarm|(% style="width:452px" %)The number of unconfirmed history alarm
229 |=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out prompt|(% style="width:452px" %)(((
230 * =0: Enable
231 * =1: Disable
232 )))
233 |=(% style="width: 160px;" %)HSW12|(% style="width:282px" %)Screen swicth|(% style="width:452px" %)(((
234 * = 0: Only HSW control the screen switch, and the sreens of all users will switch.
235 * = 1: Only HUW control the screen switch, and all users do not affect each other.
236 )))
237 |=(% style="width: 160px;" %)HSW13|(% style="width:282px" %)Screen switch register|(% style="width:452px" %)Equal to different values, the screen jumps to the corresponding screen number of the screen.
238 |=(% style="width: 160px;" %)HSW24|(% style="width:282px" %)Reboot HMI|=(% style="width: 452px;" %)1: Reboot
239 |=(% style="width: 160px;" %)HSW28|(% style="width:282px" %)Local time: year|(% style="width:452px" %)Range: 0~~9999 (system reserved)
240 |=(% style="width: 160px;" %)HSW29|(% style="width:282px" %)Local time: month|(% style="width:452px" %)Range: 01~~12 (system reserved)
241 |=(% style="width: 160px;" %)HSW30|(% style="width:282px" %)Local time: day|(% style="width:452px" %)Range: 01~~31 (system reserved)
242 |=(% style="width: 160px;" %)HSW31|(% style="width:282px" %)Local time: hour|(% style="width:452px" %)Range: 0~~23 (system reserved)
243 |=(% style="width: 160px;" %)HSW32|(% style="width:282px" %)Local time: minute|(% style="width:452px" %)Range: 0~~59 (system reserved)
244 |=(% style="width: 160px;" %)HSW33|(% style="width:282px" %)Local time: second|(% style="width:452px" %)Range: 0~~59 (system reserved)
245 |=(% style="width: 160px;" %)HSW34|(% style="width:282px" %)Local time: week|(% style="width:452px" %)(((
246 * =0: Sunday.
247 * =1: Monday.
248 * =2: Tuesday.
249 * =3: Wednesday.
250 * =4: Thursday.
251 * =5: Friday.
252 * =6: Saturday.
253 )))
254 |=(% style="width: 160px;" %)HSW39|(% style="width:282px" %)Beep type(Only valid in HMI V2.0 System)|(% style="width:452px" %)Type range: 1-5, Default is 1.
255 |=(% style="width: 160px;" %)HSW134|(% style="width:282px" %)(((
256 Whether the Script is read through
257
258
259 )))|(% style="width:452px" %)(((
260 (% class="box infomessage" %)
261 (((
262 **✎Note:** If want to read-only or write-only, please enable this settings.
263 )))
264
265 * =0: Read from HMI cache(Default)
266 * =1: Read from PLC directly
267 )))
268 |=(% style="width: 160px;" %)HSW135|(% style="width:282px" %)Confirm installment password|(% style="width:452px" %)Confirm button for installment password
269 |=(% style="width: 160px;" %)HSW151|(% style="width:282px" %)Installment due|(% style="width:452px" %)Number of days to installment due
270 |=(% style="width: 160px;" %)HSW185~~200|(% style="width:282px" %)Installment password|(% style="width:452px" %)Enter installment password
271 |=(% style="width: 160px;" %)HSW242|(% style="width:282px" %)(((
272 Prompt result of recipe operation
273
274 * Upload: Data is written from address to file
275 * Download: Data is written from a file to an address
276 )))|(% style="width:452px" %)(((
277 * =1: Download recipe, start
278 * =2: Download recipe, execution error
279 * =3: Download recipe, files don't exist
280 * =4: Download recipe, members don't exist
281 * =5: Download recipe, groups don't exist
282 * =6: Download recipe, success
283 * =7: Upload recipe, start
284 * =8: Upload recipe, execution error
285 * =9: Upload recipe, files don't exist
286 * =10: Upload recipe, members don't exist
287 * =11: Upload recipe, groups don't exist
288 * =12: Upload recipe, success
289 * =13: Insert recipe, start
290 * =14: Insert recipe, execution error
291 * =15: Insert recipe, files don't exist
292 * =16: Insert recipe, members don't exist
293 * =17: Insert recipe, groups don't exist
294 * =18: Insert recipe, success
295 * =19: Delete recipe, start
296 * =20: Delete recipe, execution error
297 * =21: Delete recipe, files don't exist
298 * =22: Delete recipe, members don't exist
299 * =23: Delete recipe, groups don't exist
300 * =24: Delete recipe, success
301 * =25: Delete and sort recipe, start
302 * =26: Delete recipe and sort, execution error
303 * =27: Delete recipe and sort, files don't exist
304 * =28: Delete recipe and sort, members don't exist
305 * =29: Delete recipe and sort, groups don't exist
306 * =30: Delete recipe and sort, success
307 * =37: CSV recipe files import successfully
308 * =38: CSV recipe files import failed.
309 )))
310 |=(% style="width: 160px;" %)HSW243|(% style="width:282px" %)Prompt result of recipe index|(% style="width:452px" %)(((
311 * =31: Recipe index, start
312 * =32: Recipe index, execution error
313 * =33: Recipe index, files don't exist
314 * =34: Recipe index, members don't exist
315 * =35: Recipe index, groups don't exist
316 * =36: Recipe index, success
317 )))
318 |=(% style="width: 160px;" %)HSW521|(% style="width:282px" %)Delete graph and alarm record|(% style="width:452px" %)(((
319 * =0: No operation
320 * =1: HSX521.0=1, delete all records.
321 * =2: HSX521.1=1, delete all trend graph.
322 * =4: HSX521.2=1, delete all alarms.
323 * =16: HSX521.4=1, delete history XY plot.
324 * =32: HSX521.5=1, delete data records in SD card or USB flash disk;(Please make a setting which is saved to USB flash disk or SD card in project setting).
325 * =64: HSX521.6=1, delete alarms records in SD card or USB flash disk; (Please make a setting which is saved to USB flash disk or SD card in project setting).
326 )))
327 |=(% style="width: 160px;" %)HSW522|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the USB flash disk|(% style="width:452px" %)(((
328 * =0: No operation
329 * =1: HSX522.0=1, copy all record
330 * =2: HSX522.2=1, copy history XY trend graph
331 * =8: HSX522.3=1, copy alarm record
332 * =32: HSX522.5=1, copy recipe
333 )))
334 |=(% style="width: 160px;" %)HSW523|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the SD card|(% style="width:452px" %)(((
335 * =0: No operation
336 * =1: HSX523.0=1, copy all record
337 * =4: HSX523.2=1, copy history XY trend graph
338 * =8: HSX523.3=1, copy alarm record
339 )))
340 |=(% style="width: 160px;" %)HSW524|(% style="width:282px" %)Copy and paste the alarm/data files in SD card to the USB flash disk|(% style="width:452px" %)(((
341 * =0: no operation
342 * =4: HSX524.2=1, copy history XY trend graph
343 * =8: HSX524.3=1, copy alarm record
344 * =16: HSX524.4=1, copy history alarm record
345 * =32: HSX524.5=1, copy data record
346 )))
347 |=(% style="width: 160px;" %)HSW525|(% style="width:282px" %)Copy and paste the alarm/data files in USB flash disk to SD card|(% style="width:452px" %)(((
348 * =0: no operation
349 * =4: HSX525.2=1, copy history XY trend graph
350 * =8: HSX525.3=1, copy alarm record
351 * =16: HSX525.4=1, copy history alarm record
352 * =32: HSX525.5= 1, copy data record
353 )))
354 |=(% style="width: 160px;" %)HSW526|(% style="width:282px" %)Delete file list|(% style="width:452px" %)(((
355 * =0: no operation
356 * =1: HSX526.0=1, delete designated file
357 * =2: HSX526.1=1, delete all files
358 )))
359 |=(% style="width: 160px;" %)HSW527|(% style="width:282px" %)Eject USB flash disk/SD card|(% style="width:452px" %)(((
360 * =0: No operation
361 * =1: Eject USB flash disk
362 * =2: Eject SD card
363 )))
364 |=(% style="width: 160px;" %)HSW528|(% style="width:282px" %)The state of USB flash disk|(% style="width:452px" %)(((
365 * =1: USB flash disk is detected
366 * =2: Ejecting USB flash disk, please waiting…
367 * =3: USB flash disk ejected
368 )))
369 |=(% style="width: 160px;" %)HSW529|(% style="width:282px" %)The state of SD card|(% style="width:452px" %)(((
370 * =1: SD card is detected
371 * =2: Ejecting SD card, please waiting…
372 * =3: SD card ejected
373 )))
374 |=(% style="width: 160px;" %)HSW550~~849|(% style="width:282px" %)Communication control|(% style="width:452px" %)For communication control and communication lamp (please refer to "[[Communication control>>https://docs.we-con.com.cn/bin/view/PIStudio/13.HMI%20internal%20registers/#HCommunicationcontrol]]" sector for detailed)
375 |=(% style="width: 160px;" %)HSW850|(% style="width:282px" %)(((
376 Network state
377
378 (4G, WIFI and Ethernet)
379 )))|(% style="width:452px" %)(((
380 In HMI V1.0
381
382 * =0: Network is disconnected.
383 * =1: only LAN connected, and APP can't access HMI.
384 * =2: WECON Cloud connected , APP and web could access HMI.
385
386 In HMI V2.0
387
388 * =0: Network is disconnected.
389 * =1: Network is connected.
390 )))
391 |=(% style="width: 160px;" %)HSW855|(% style="width:282px" %)Backlight Control|(% style="width:452px" %)(((
392 * HSX855.0=1: turn on the backlight and reset automatically after being triggered.
393 * HSX855.1=1: turn off the backlight and reset automatically after being triggered.
394 )))
395 |=(% style="width: 160px;" %)HSW856|(% style="width:282px" %)Whether to close the indirect screen when the current screen is switched to the other screen)|(% style="width:452px" %)(((
396 * =0: close the sub-screen, including the indirect screen;
397 * =1: not to close.
398 )))
399 |=(% style="width: 160px;" %)HSW857|(% style="width:282px" %)Permission in remote access (web page, mobile APP, cloud platform, etc.)|(% style="width:452px" %)(((
400 * =0: users could switch the screen, control the switch and update data in remote access.
401 * =1: users could only control function switch (only switch the screen), view data and switch state, but could not operate or update them.
402 * =2: users could neither operate the screen switch, nor switch operation and data modification, only view. (The ig series and 8000/9000 series with -R after system upgrade)
403 )))
404 |=(% style="width: 160px;" %)HSW860~~861|(% style="width:282px" %)Data partition remaining space|(% style="width:452px" %)Display the data partition remaining space, updated every minute, unit(**kB**)
405 |=(% style="width: 160px;" %)HSW880|(% style="width:282px" %)Enable data partition remaining space|(% style="width:452px" %)(((
406 ~=1, able to view the data partition remaining space from HSW860~~861.
407
408 ~=Other value except 1, disable the viewing function.
409 )))
410 |=(% style="width: 160px;" %)HSW881|(% style="width:282px" %)Storage of Record files|(% style="width:452px" %)(((
411 It is used for controlling saving alarm/data record files to U disk / SD card.
412
413 * = 0: Save to storage.
414 * = 1: Don't save to storage.
415 )))
416 |=(% style="width: 160px;" %)HSW882|(% style="width:282px" %)Storage device status|(% style="width:452px" %)(((
417 * HDX882.0=0 USB flash doesn't execute storage or storage finished.
418 * HDX882.0=1 USB flash is reading data, don't remove USB flash.
419 * HDX882.1=0 SD card doesn't execute storage or storage finished.
420 * HDX882.1=1 SD card is reading data, don't remove SD card.
421 )))
422 |=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)(((
423 * = 0: Do not enter the network configuration interface
424 * = 1: Enter the system network configuration interface.
425 ** ig series HMI only supports to enter the system interface
426
427 )))
428 |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)(((
429 * = 0: displayed by object setting.
430 * = 1: control address read failure, the address control of all objects is hidden, not displayed.
431 * = 2: control address read failure, the address control of all objects is displayed, not hidden.
432 )))
433 |=(% style="width: 160px;" %)HSW893|(% style="width:282px" %)(((
434 User Permission Control Address, same as HUW1000 feature, please refer to chapter "[[User Permission>>http://13.229.109.52:8080/wiki/pistudio/view/Helps/08.Basic%20Function/#HUserPermission]]"
435
436 **✎Note: **This address can only take effect when it is operated in the real HMI, and the operation is invalid on Web/App side.
437 )))|(% style="width:452px" %)(((
438 * =1: User Log in
439 * =2: Change User password
440 * =3: User Log out
441 * =4: New user
442 * =5: Delete user
443 * =6: Add user rights
444 * =8: Add Hide features
445 * =9: Delete Profile
446 * =10: Export Profile
447 * =11: Import profile
448 * =12: Export log file
449 * =13: Delete log file
450 )))
451 |=(% style="width: 160px;" %)HSW900|(% style="width:282px" %)Quick update frequency settings for objects|(% style="width:452px" %)(((
452 Valid when the object is enabled for "quick update". Default: 5.
453
454 Range: 1 (fastest) - 50 (slowest)
455 )))
456 |=(% style="width: 160px;" %)HSW920|(% style="width:282px" %)Static mode Maximum periods|(% style="width:452px" %)Numeric Input/ Display (range: 0-12)
457 |=(% style="width: 160px;" %)HSW921 ~~ 924|(% style="width:282px" %)Static mode Admin key|(% style="width:452px" %)Character Input/ Display (length: 8)
458 |=(% style="width: 160px;" %)HSW925 ~~ 928|(% style="width:282px" %)1^^st^^ period key (Static mode)|(% style="width:452px" %)Character Input/ Display (length: 8)
459 |=(% style="width: 160px;" %)HSW929 ~~ 933|(% style="width:282px" %)1^^st^^ expiry time (Static mode)|(% style="width:452px" %)Numeric Input/ Display (YYYYMMDDHHMM)
460 |=(% style="width: 160px;" %)HSW935 ~~ 938|(% style="width:282px" %)2^^nd^^ period key (Static mode)|(% style="width:452px" %)Character Input/ Display (length: 8)
461 |=(% style="width: 160px;" %)HSW939 ~~ 943|(% style="width:282px" %)2^^nd ^^expiry time (Static mode)|(% style="width:452px" %)Numeric Input/ Display (YYYYMMDDHHMM)
462 |=(% style="width: 160px;" %)HSW945 ~~ 948|(% style="width:282px" %)3^^rd^^ period key (Static mode)|(% style="width:452px" %)Character Input/ Display (length: 8)
463 |=(% style="width: 160px;" %)HSW949 ~~ 953|(% style="width:282px" %)3^^rd ^^expiry time (Static mode)|(% style="width:452px" %)Numeric Input/ Display (YYYYMMDDHHMM)
464 |=(% style="width: 160px;" %)HSW955 ~~ 958|(% style="width:282px" %)4^^th^^ period key (Static mode)|(% style="width:452px" %)Character Input/ Display (length: 8)
465 |=(% style="width: 160px;" %)HSW959 ~~ 963|(% style="width:282px" %)4^^th ^^expiry time (Static mode)|(% style="width:452px" %)Numeric Input/ Display (YYYYMMDDHHMM)
466 |=(% style="width: 160px;" %)HSW965 ~~ 968|(% style="width:282px" %)5^^th^^ period key (Static mode)|(% style="width:452px" %)Character Input/ Display (length: 8)
467 |=(% style="width: 160px;" %)HSW969 ~~ 973|(% style="width:282px" %)5^^th ^^expiry time (Static mode)|(% style="width:452px" %)Numeric Input/ Display (YYYYMMDDHHMM)
468 |=(% style="width: 160px;" %)HSW975 ~~ 978|(% style="width:282px" %)6^^th^^ period key (Static mode)|(% style="width:452px" %)Character Input/ Display (length: 8)
469 |=(% style="width: 160px;" %)HSW979 ~~ 983|(% style="width:282px" %)6^^th ^^expiry time (Static mode)|(% style="width:452px" %)Numeric Input/ Display (YYYYMMDDHHMM)
470 |=(% style="width: 160px;" %)HSW985 ~~ 988|(% style="width:282px" %)7^^th^^ period key (Static mode)|(% style="width:452px" %)Character Input/ Display (length: 8)
471 |=(% style="width: 160px;" %)HSW989 ~~ 993|(% style="width:282px" %)7^^th ^^expiry time (Static mode)|(% style="width:452px" %)Numeric Input/ Display (YYYYMMDDHHMM)
472 |=(% style="width: 160px;" %)HSW995 ~~ 998|(% style="width:282px" %)8^^th^^ period key (Static mode)|(% style="width:452px" %)Character Input/ Display (length: 8)
473 |=(% style="width: 160px;" %)HSW999 ~~ 1003|(% style="width:282px" %)8^^th ^^expiry time (Static mode)|(% style="width:452px" %)Numeric Input/ Display (YYYYMMDDHHMM)
474 |=(% style="width: 160px;" %)HSW1005 ~~1008|(% style="width:282px" %)9^^th^^ period key (Static mode)|(% style="width:452px" %)Character Input/ Display (length: 8)
475 |=(% style="width: 160px;" %)HSW1009 ~~ 1013|(% style="width:282px" %)9^^th ^^expiry time (Static mode)|(% style="width:452px" %)Numeric Input/ Display (YYYYMMDDHHMM)
476 |=(% style="width: 160px;" %)HSW1015 ~~1018|(% style="width:282px" %)10^^th^^ period key (Static mode)|(% style="width:452px" %)Character Input/ Display (length: 8)
477 |=(% style="width: 160px;" %)HSW1019 ~~ 1023|(% style="width:282px" %)10^^th ^^expiry time (Static mode)|(% style="width:452px" %)Numeric Input/ Display (YYYYMMDDHHMM)
478 |=(% style="width: 160px;" %)HSW1025 ~~1028|(% style="width:282px" %)11^^th^^ period key (Static mode)|(% style="width:452px" %)Character Input/ Display (length: 8)
479 |=(% style="width: 160px;" %)HSW1029 ~~ 1033|(% style="width:282px" %)11^^th ^^expiry time (Static mode)|(% style="width:452px" %)Numeric Input/ Display (YYYYMMDDHHMM)
480 |=(% style="width: 160px;" %)HSW1035 ~~1038|(% style="width:282px" %)12^^th^^ period key (Static mode)|(% style="width:452px" %)Character Input/ Display (length: 8)
481 |=(% style="width: 160px;" %)HSW1039 ~~ 1043|(% style="width:282px" %)12^^th ^^expiry time (Static mode)|(% style="width:452px" %)Numeric Input/ Display (YYYYMMDDHHMM)
482 |=(% style="width: 160px;" %)HSW1046|(% style="width:282px" %)Current period (Static mode)|(% style="width:452px" %)Current period (Range 1-13)
483 |=(% style="width: 160px;" %)HSW1047|(% style="width:282px" %)Save settings (Static mode)|(% style="width:452px" %)(((
484 * HSX1047.0=1: Save static installment information
485 * HSX1047.1=1: Write installment information to registers
486 )))
487 |=(% style="width: 160px;" %)HSW1050~~HSW1065|(% style="width:282px" %)The recipe name that can input csv format|(% style="width:452px" %)Input CSV format recipe file name through "Character Input/ Display".(This function should be used in combination with the recipefunction)
488 |=(% style="width: 160px;" %)HSW1066|(% style="width:282px" %)Configure the type of the CSV file imported|(% style="width:452px" %)(((
489 The CSV file type imported (This function should be used in combination with the recipe function)
490
491 * =0: Import customed CSV file. The data in the file is valid.
492 * =1: Import ordinary recipe files of regular series HMI. The 1st row of the file is invalid.
493 * =2: Import special recipe files of regular series HMI. The 1st and 3nd rows and the 1st colume of the file is invalid.
494 )))
495 |=(% style="width: 160px;" %)HSW1067|(% style="width:282px" %)Location where the CSV file is saved|(% style="width:452px" %)(((
496 Set the path of CSV file (This function should be used in combination with the recipe function)
497
498 * =0: In the CsvFile directory of the USB stick
499 * =1: In the CsvFile directory of the SD card
500 )))
501 |=(% style="width: 160px;" %)HSW1070|(% style="width:282px" %)The time interval (seconds) since the last time the screen was clicked|(% style="width:452px" %)(((
502 Shows how long the current screen has not been clicked, using a decimal unsigned double word (Numeric Input/ Display).
503
504 (% class="box infomessage" %)
505 (((
506 **✎Note: **This register is cleared to zero regardless of which user clicks on the screen.
507 )))
508 )))
509 |=(% style="width: 160px;" %)HSW1073|(% style="width:282px" %)Corresponding key value from keyboard|(% style="width:452px" %)Display the key value of the currently pressed key, the key value is shown in Table 1 (not updated when the character input display is being input)
510 |=(% style="width: 160px;" %)HSW1074|(% style="width:282px" %)Keyboard key status|(% style="width:452px" %)Display the current button status (not updated when the numeric input display is being input)(((
511 * =0: key release
512 * =1: key press
513 * =2: Long press the button
514 )))
515 |=(% style="width: 160px;" %)HSW1075|(% style="width:282px" %)Cursor speed|(% style="width:452px" %)Control the cursor movement speed, the range is 0~100, the default is 20
516 |=(% style="width: 160px;" %)HSW1076|(% style="width:282px" %)Cursor x coordinate value|(% style="width:452px" %)Record the x value at the current position of the cursor, range: 0 to screen width -1
517 |=(% style="width: 160px;" %)HSW1077|(% style="width:282px" %)Cursor y coordinate value|(% style="width:452px" %)Record the y value at the current position of the cursor, range: 0 to screen height-1
518 |=(% style="width: 160px;" %)HSW1078|(% style="width:282px" %)Corresponding ASCII code for keyboard keys|(% style="width:452px" %)Only the ASCII value of letters, numbers, and symbols are displayed, and the ASCII value of the function button is not displayed.
519 |=(% style="width: 160px;" %)HSW1079|(% style="width:282px" %)Trigger to set the cursor position and set the Enter key mode|(% style="width:452px" %)(((
520 * HSX1079.0=1: Set the cursor position according to the cursor xy register value;
521 * HSX1079.1=0: When the numeric/character input display is being input, press Enter to end the input, no value/text part is being input, Enter is a normal click;
522 * HSX1079.1=1 Regardless of whether the numeric/character component is inputting the Enter key, only normal click is performed, and the keyboard end input is not performed.
523 )))
524 |=(% style="width: 160px;" %)HSW1083|(% style="width:282px" %)Naming method for printing object screenshots|(% style="width:452px" %)(((
525 Example: The time is 2019-01-04 14:29:10 (523 milliseconds), the screen number is 0, and the object ID is 2.
526
527 * =0: Use year, month, day, hour, minute, second, millisecond, screen number, part number to name, such as: 2019010414291052302.bmp.
528 * =1: Name using year, month, day, hour, minute, and second.
529
530 For example: 20190104142910.bmp.
531 )))
532 |=(% style="width: 160px;" %)HSW1086|(% style="width:282px" %)Control address mapping polling cycle, unit: ms|(% style="width:452px" %)(((
533 Address mapping polling cycle, effective range: 40~~1000ms, default: 300ms.
534
535 * When the set value is greater than 1000, the value is 1000.
536 * When the set value is lower than 40, it changes to the default value 300
537 )))
538 |=(% style="width: 160px;" %)HSW1087|(% style="width:282px" %)Control write interval in address mapping|(% style="width:452px" %)(((
539 After reading data to the device for N times, Perform an address mapping write operation. N is the interval value. The effective range: 0~~5, and default is 2.
540
541 When N more than 5, it is 5.
542
543 0 is the fastest and 5 is the slowest.
544 )))
545 |=(% style="width: 160px;" %)HSW1088|(% style="width:282px" %)Control the write interval of script|(% style="width:452px" %)(((
546 After reading data to the device for N times, Perform a script write operation. N is the interval value. The effective range: 0~~5, and default is 2.
547
548 When N more than 5, it is 5.
549
550 0 is the fastest and 5 is the slowest.
551 )))
552 |=(% style="width: 160px;" %)HSW1089|(% style="width:282px" %)Control interval of read through|(% style="width:452px" %)(((
553 After reading data to the device for N times, Perform a read through operation. N is the interval value. The effective range: 0~~5, and default is 2.
554
555 When N more than 5, it is 5.
556
557 0 is the fastest and 5 is the slowest.
558 )))
559 |=(% style="width: 160px;" %)HSW1100|(% colspan="1" rowspan="4" style="width:282px" %)Set the Master IP for Multi-link|(% style="width:452px" %)High word 1 for Master IP address of multi-link
560 |=(% style="width: 160px;" %)HSW1101|(% style="width:452px" %)High word 2 for Master IP address of multi-link
561 |=(% style="width: 160px;" %)HSW1102|(% style="width:452px" %)High word 3 for Master IP address of multi-link
562 |=(% style="width: 160px;" %)HSW1103|(% style="width:452px" %)High word 4 for Master IP address of multi-link
563 |=(% style="width: 160px;" %)HSW1104|(% style="width:282px" %)Control connection to Master or not for Multi-link slave device|(% style="width:452px" %)(((
564 * =1: Connect to the Master
565 * =0: Do not connect to Master
566 )))
567 |=(% style="width: 160px;" %)HSW1141|(% style="width:282px" %)Release alarm|(% style="width:452px" %)(((
568 * =0, Default value
569 * =1, Release the alarm generated before the last power-down when starting up
570 )))
571 |=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
572 |=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
573 |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)(((
574 * =0, Disable
575 * =1, Enable
576 )))
577 |=(% style="width: 160px;" %)HSW1451|(% style="width:282px" %)Whether the object level passwords are independent of each other|(% style="width:452px" %)(((
578 * =0, No, high-level passwords can unlock low-level
579 * = 1, Yes, high-level passwords cannot unlock low-level
580 )))
581 |=(% style="width: 160px;" %)HSW1452|(% style="width:282px" %)Initialization level|(% style="width:452px" %)Initialization level while HMI running
582 |=(% style="width: 160px;" %)HSW1454~~1457|(% style="width:282px" %)Password for Level 1|(% style="width:452px" %)(((
583 Display password for level 1, using character input object, up to 8 characters (numbers, letters (case sensitive))
584 )))
585 |=(% style="width: 160px;" %)HSW1458~~1461|(% style="width:282px" %)Password for Level 2|(% style="width:452px" %)Display password for level 2, using character input object, up to 8 characters (numbers, letters (case sensitive))
586 |=(% style="width: 160px;" %)HSW1462~~1465|(% style="width:282px" %)Password for Level 3|(% style="width:452px" %)Display password for level 3, using character input object, up to 8 characters (numbers, letters (case sensitive))
587 |=(% style="width: 160px;" %)HSW1466~~1469|(% style="width:282px" %)Password for Level 4|(% style="width:452px" %)Display password for level 4, using character input object, up to 8 characters (numbers, letters (case sensitive))
588 |=(% style="width: 160px;" %)HSW1470~~1473|(% style="width:282px" %)Password for Level 5|(% style="width:452px" %)Display password for level 5, using character input object, up to 8 characters (numbers, letters (case sensitive))
589 |=(% style="width: 160px;" %)HSW1474~~1477|(% style="width:282px" %)Password for Level 6|(% style="width:452px" %)Display password for level 6, using character input object, up to 8 characters (numbers, letters (case sensitive))
590 |=(% style="width: 160px;" %)HSW1478~~1481|(% style="width:282px" %)Password for Level 7|(% style="width:452px" %)Display password for level 7, using character input object, up to 8 characters (numbers, letters (case sensitive))
591 |=(% style="width: 160px;" %)HSW1482~~1485|(% style="width:282px" %)Password for Level 8|(% style="width:452px" %)Display password for level 8, using character input object, up to 8 characters (numbers, letters (case sensitive))
592 |=(% style="width: 160px;" %)HSW1486~~1489|(% style="width:282px" %)Password for Level 9|(% style="width:452px" %)Display password for level 9, using character input object, up to 8 characters (numbers, letters (case sensitive))
593 |=(% style="width: 160px;" %)HSW1490~~1493|(% style="width:282px" %)Password for Level 10|(% style="width:452px" %)Display password for level 10, using character input object, up to 8 characters (numbers, letters (case sensitive))
594 |=(% style="width: 160px;" %)HSW1494~~1497|(% style="width:282px" %)Password for Level 11|(% style="width:452px" %)Display password for level 11, using character input object, up to 8 characters (numbers, letters (case sensitive))
595 |=(% style="width: 160px;" %)HSW1498~~1501|(% style="width:282px" %)Password for Level 12|(% style="width:452px" %)Display password for level 12, using character input object, up to 8 characters (numbers, letters (case sensitive))
596 |=(% style="width: 160px;" %)HSW1502|(% style="width:282px" %)Modify password for object level|(% style="width:452px" %)(((
597 * HSX1502.0=1: Modification comfirmed. Save the data of HSW1450~~HSW1501 to a file for immediate effect.
598 * HSX1502.1=1:Modification cancelled. Restore the current data of hSW1450-HSW1501 to the data saved in the file last time.
599 )))
600 |=(% style="width: 160px;" %)HSW1509|(% style="width:282px" %)Curve width|(% style="width:452px" %)(((
601 * =0: Use the curve width set by project default.
602 * =1 to 10: use special register to set curve width.
603 )))
604 |=(% style="width: 160px;" %)HSW1603|(% style="width:282px" %)Number of current unreleased alarms|(% style="width:452px" %)The number of current unreleased alarms in alarm record file.
605 |=(% style="width: 160px;" %)HSW1604|(% style="width:282px" %)The auxiliary judgment address when the control bit in the Object Lock fails to be read|(% style="width:452px" %)(((
606 * =0: The auxiliary address is invalid.
607 * =1: When the communication fails, lock the object.
608 * =2: When the communication fails, unlock the object.
609 * =Others: The auxiliary address is invalid.
610 )))
611 |=(% style="width: 160px;" %)HSW1605|(% style="width:282px" %)BCD format natural decimal control|(% style="width:452px" %)(((
612 Whether to display natural decimals with decimal point in BCD format:
613
614 * 0=Not enabled.
615 * 1=Enable.
616
617 (For example, 56.20 is displayed as 56.2, 33.00 is displayed as 33)
618 )))
619 |=(% style="width: 160px;" %)HSW1606|(% style="width:282px" %)User permission modification control|(% style="width:452px" %)(((
620 * =0: Ordinary users are allowed to modify permissions and other operations
621 * =1: Only the administrator can operate (default is 0)
622 )))
623 |=(% style="width: 160px;" %)HSW1607|(% style="width:282px" %)The spacing value among the drop-down items of the drop-down list|(% style="width:452px" %)10 to 50 is effective, such as: 23 is 2.3 times the height of the object.
624 |=(% style="width: 160px;" %)HSW1611|(% style="width:282px" %)(((
625 Traditional recipe transfer
626 )))|(% style="width:452px" %)(((
627 * =1: download traditional recipe.
628 * =2: upload the traditional recipe.
629 )))
630 |=(% style="width: 160px;" %)HSW1612|(% style="width:282px" %)Traditional Recipe group number|(% style="width:452px" %)Traditional Recipe group number
631 |=(% style="width: 160px;" %)HSW1613|(% style="width:282px" %)Display the status of network card|(% style="width:452px" %)(((
632 * =1: Normal
633 * =Others: Abnormal
634 )))
635 |=(% style="width: 160px;" %)HSW1614~~1623|(% style="width:282px" %)Download speed per second|(% style="width:452px" %)Display the download speed per second. (The value is string)
636 |=(% style="width: 160px;" %)HSW1624~~1633|(% style="width:282px" %)Upnload speed per second|(% style="width:452px" %)Display the upload speed per second. (The value is string)
637 |=(% style="width: 160px;" %)HSW1634~~1643|(% style="width:282px" %)Flow consumption rate|(% style="width:452px" %)Display the total flow rate per second (The value is string)
638 |=(% style="width: 160px;" %)HSW1644~~1653|(% style="width:282px" %)Download flow consumption after power on|(% style="width:452px" %)Display the download flow consumption after power on (The value is string)
639 |=(% style="width: 160px;" %)HSW1654~~1663|(% style="width:282px" %)Upload flow consumption after power on|(% style="width:452px" %)Display the upload flow consumption after power on (The value is string)
640 |=(% style="width: 160px;" %)HSW1664~~1673|(% style="width:282px" %)Total flow consumption after power on|(% style="width:452px" %)Display the total flow consumption after power on (download and upload). (The value is string)
641 |=(% style="width: 160px;" %)HSW1674~~1683|(% style="width:282px" %)Historical flow consumption|(% style="width:452px" %)Display historical flow consumption (download and upload). (The value is string)
642 |=(% style="width: 160px;" %)HSW1684~~1693|(% style="width:282px" %)Flow consumption in 10 minutes|(% style="width:452px" %)Flow consumption in 10 minutes (download and upload). (The value is string)
643 |=(% style="width: 160px;" %)HSW1694~~1703|(% style="width:282px" %)Flow consumption in 30 minutes|(% style="width:452px" %)Flow consumption in 30 minutes (download and upload). (The value is string)
644 |=(% style="width: 160px;" %)HSW1704~~1713|(% style="width:282px" %)Flow consumption in 3 hours|(% style="width:452px" %)Flow consumption in 3 hours (download and upload). (The value is string)
645 |=(% style="width: 160px;" %)HSW1715|(% style="width:282px" %)Reset flow|(% style="width:452px" %)(((
646 * =1: Clear historical flow data and restart the count.
647 * =Others: Invalid
648 )))
649 |=(% style="width: 160px;" %)HSW1719|(% style="width:282px" %)Network status of Ethernet connnecting to server|(% style="width:452px" %)(((
650 * =0: Server connection exception
651 * =1: Server connection is OK
652 )))
653 |=(% style="width: 160px;" %)HSW1720|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in WIFI network status (It is valid when HMI is connected to WIFI)|(% style="width:452px" %)Local IP address high byte 1
654 |=(% style="width: 160px;" %)HSW1721|(% style="width:452px" %)Local IP address high byte 2
655 |=(% style="width: 160px;" %)HSW1722|(% style="width:452px" %)Local IP address high byte 3
656 |=(% style="width: 160px;" %)HSW1723|(% style="width:452px" %)Local IP address high byte 4
657 |=(% style="width: 160px;" %)HSW1724|(% style="width:452px" %)Local mask IP address high byte 1
658 |=(% style="width: 160px;" %)HSW1725|(% style="width:452px" %)Local mask IP address high byte 2
659 |=(% style="width: 160px;" %)HSW1726|(% style="width:452px" %)Local mask IP address high byte 3
660 |=(% style="width: 160px;" %)HSW1727|(% style="width:452px" %)Local mask IP address high byte 4
661 |=(% style="width: 160px;" %)HSW1728|(% style="width:452px" %)Local gateway IP address high byte 1
662 |=(% style="width: 160px;" %)HSW1729|(% style="width:452px" %)Local gateway IP address high byte 2
663 |=(% style="width: 160px;" %)HSW1730|(% style="width:452px" %)Local gateway IP address high byte 3
664 |=(% style="width: 160px;" %)HSW1731|(% style="width:452px" %)Local gateway IP address high byte 4
665 |=(% style="width: 160px;" %)HSW1733|(% colspan="1" rowspan="6" style="width:282px" %)(((
666 Display the MAC code of current WIFI
667
668 (display in hexadecimal)
669 )))|(% style="width:452px" %)Local MAC address high byte 1 (hexadecimal)
670 |=(% style="width: 160px;" %)HSW1734|(% style="width:452px" %)Local MAC address high byte 2 (hexadecimal)
671 |=(% style="width: 160px;" %)HSW1735|(% style="width:452px" %)Local MAC address high byte 3 (hexadecimal)
672 |=(% style="width: 160px;" %)HSW1736|(% style="width:452px" %)Local MAC address high byte 4 (hexadecimal)
673 |=(% style="width: 160px;" %)HSW1737|(% style="width:452px" %)Local MAC address high byte 5 (hexadecimal)
674 |=(% style="width: 160px;" %)HSW1738|(% style="width:452px" %)Local MAC address high byte 6 (hexadecimal)
675 |=(% style="width: 160px;" %)HSW1739|(% style="width:282px" %)Display the network status of WIFI|(% style="width:452px" %)(((
676 * =0: Server connection exception
677 * =1: Server connection is OK
678 )))
679 |=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)(((
680 Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890)
681 )))
682 |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1
683 |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2
684 |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3
685 |=(% style="width: 160px;" %)HSW1744|(% style="width:452px" %)Local IP address high byte 4
686 |=(% style="width: 160px;" %)HSW1745|(% style="width:452px" %)Local mask IP address high byte 1
687 |=(% style="width: 160px;" %)HSW1746|(% style="width:452px" %)Local mask IP address high byte 2
688 |=(% style="width: 160px;" %)HSW1747|(% style="width:452px" %)Local mask IP address high byte 3
689 |=(% style="width: 160px;" %)HSW1748|(% style="width:452px" %)Local mask IP address high byte 4
690 |=(% style="width: 160px;" %)HSW1749|(% style="width:452px" %)Local gateway IP address high byte 1
691 |=(% style="width: 160px;" %)HSW1750|(% style="width:452px" %)Local gateway IP address high byte 2
692 |=(% style="width: 160px;" %)HSW1751|(% style="width:452px" %)Local gateway IP address high byte 3
693 |=(% style="width: 160px;" %)HSW1752|(% style="width:452px" %)Local gateway IP address high byte 4
694 |=(% style="width: 160px;" %)HSW1754|(% colspan="1" rowspan="6" style="width:282px" %)(((
695 Display the MAC code of current WIFI
696
697 (display in hexadecimal)
698 )))|(% style="width:452px" %)Local MAC address high byte 1 (hexadecimal)
699 |=(% style="width: 160px;" %)HSW1755|(% style="width:452px" %)Local MAC address high byte 2 (hexadecimal)
700 |=(% style="width: 160px;" %)HSW1756|(% style="width:452px" %)Local MAC address high byte 3 (hexadecimal)
701 |=(% style="width: 160px;" %)HSW1757|(% style="width:452px" %)Local MAC address high byte 4 (hexadecimal)
702 |=(% style="width: 160px;" %)HSW1758|(% style="width:452px" %)Local MAC address high byte 5 (hexadecimal)
703 |=(% style="width: 160px;" %)HSW1759|(% style="width:452px" %)Local MAC address high byte 6 (hexadecimal)
704 |=(% style="width: 160px;" %)HSW1760|(% style="width:282px" %)Display 4G network status|(% style="width:452px" %)(((
705 * =0: Server connection exception
706 * =1: Server connection is OK
707 )))
708 |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger
709 |=(% style="width: 160px;" %)(((
710 HSW1762
711 )))|(% colspan="1" rowspan="13" style="width:282px" %)(((
712 Note: Valid when Ethernet2 of HMI is plugged into the network cable.
713 ①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
714 ②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
715 ③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
716 ④.IP related registers can be read and written (only static IP mode can be written).
717 )))|(% style="width:452px" %)(((
718 Ethernet2 Local IP address high byte 1
719 )))
720 |=(% style="width: 160px;" %)(((
721 HSW1763
722 )))|(% style="width:452px" %)(((
723 Ethernet2 Local IP address high byte 2
724 )))
725 |=(% style="width: 160px;" %)(((
726 HSW1764
727 )))|(% style="width:452px" %)(((
728 Ethernet2 Local IP address high byte 3
729 )))
730 |=(% style="width: 160px;" %)(((
731 HSW1765
732 )))|(% style="width:452px" %)(((
733 Ethernet2 Local IP address high byte 4
734 )))
735 |=(% style="width: 160px;" %)(((
736 HSW1766
737 )))|(% style="width:452px" %)(((
738 Ethernet2 Local mask IP address high byte 1
739 )))
740 |=(% style="width: 160px;" %)(((
741 HSW1767
742 )))|(% style="width:452px" %)(((
743 Ethernet2 Local mask IP address high byte 2
744 )))
745 |=(% style="width: 160px;" %)(((
746 HSW1768
747 )))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3
748 |=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4
749 |=(% style="width: 160px;" %)(((
750 HSW1770
751 )))|(% style="width:452px" %)(((
752 Ethernet2 Local gateway IP address high byte 1
753 )))
754 |=(% style="width: 160px;" %)(((
755 HSW1771
756 )))|(% style="width:452px" %)(((
757 Ethernet2 Local gateway IP address high byte 2
758 )))
759 |=(% style="width: 160px;" %)(((
760 HSW1772
761 )))|(% style="width:452px" %)(((
762 Ethernet2 Local gateway IP address high byte 3
763 )))
764 |=(% style="width: 160px;" %)(((
765 HSW1773
766 )))|(% style="width:452px" %)(((
767 Ethernet2 Local gateway IP address high byte 4
768 )))
769 |=(% style="width: 160px;" %)(((
770 HSW1774
771 )))|(% style="width:452px" %)(((
772 Ethernet2 Local Port Address
773 )))
774 |=(% style="width: 160px;" %)(((
775 HSW1775
776 )))|(% colspan="1" rowspan="6" style="width:282px" %)(((
777 ①Display the MAC code of Ethernet2 NIC
778
779 (hexadecimal display)
780
781 ②Read-only mode, not modifiable
782 )))|(% style="width:452px" %)(((
783 Ethernet2 Local MAC code high byte 1
784 )))
785 |=(% style="width: 160px;" %)(((
786 HSW1776
787 )))|(% style="width:452px" %)(((
788 Ethernet2 Local MAC code high byte 2
789 )))
790 |=(% style="width: 160px;" %)(((
791 HSW1777
792 )))|(% style="width:452px" %)(((
793 Ethernet2 Local MAC code high byte 3
794 )))
795 |=(% style="width: 160px;" %)(((
796 HSW1778
797 )))|(% style="width:452px" %)(((
798 Ethernet2 Local MAC code high byte 4
799 )))
800 |=(% style="width: 160px;" %)(((
801 HSW1779
802 )))|(% style="width:452px" %)(((
803 Ethernet2 Local MAC code high byte 5
804 )))
805 |=(% style="width: 160px;" %)(((
806 HSW1780
807 )))|(% style="width:452px" %)(((
808 Ethernet2 Local MAC code high byte 6
809 )))
810 |=(% style="width: 160px;" %)(((
811 HSW1781
812 )))|(% colspan="1" rowspan="8" style="width:282px" %)(((
813 ①Display and modify DNS1 and DNS2 of Ethernet2
814
815 ②Related registers can be read and written mode (only static IP mode can be written)
816 )))|(% style="width:452px" %)(((
817 Ethernet2 Local DNS1 address high byte 1
818 )))
819 |=(% style="width: 160px;" %)(((
820 HSW1782
821 )))|(% style="width:452px" %)(((
822 Ethernet2 Local DNS1 address high byte 2
823 )))
824 |=(% style="width: 160px;" %)(((
825 HSW1783
826 )))|(% style="width:452px" %)(((
827 Ethernet2 Local DNS1 address high byte 3
828 )))
829 |=(% style="width: 160px;" %)(((
830 HSW1784
831 )))|(% style="width:452px" %)(((
832 Ethernet2 Local DNS1 address high byte 4
833 )))
834 |=(% style="width: 160px;" %)(((
835 HSW1785
836 )))|(% style="width:452px" %)(((
837 Ethernet2 Local DNS2 address high byte 1
838 )))
839 |=(% style="width: 160px;" %)(((
840 HSW1786
841 )))|(% style="width:452px" %)(((
842 Ethernet2 Local DNS2 address high byte 2
843 )))
844 |=(% style="width: 160px;" %)(((
845 HSW1787
846 )))|(% style="width:452px" %)(((
847 Ethernet2 Local DNS2 address high byte 3
848 )))
849 |=(% style="width: 160px;" %)(((
850 HSW1788
851 )))|(% style="width:452px" %)(((
852 Ethernet2 Local DNS2 address high byte 4
853 )))
854 |=(% style="width: 160px;" %)(((
855 HSW1789
856 )))|(% colspan="1" style="width:282px" %)(((
857 Display or set the dynamic or static IP mode of Ethernet2
858 )))|(% style="width:452px" %)(((
859 HSX1789.0 = 0, Static IP mode
860
861 HSX1789.0 = 1, dynamic IP mode
862 )))
863 |=(% style="width: 160px;" %)(((
864 HSW1790
865 )))|(% colspan="1" style="width:282px" %)(((
866 Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings
867 )))|(% style="width:452px" %)(((
868 ~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
869 )))
870 |=(% style="width: 160px;" %)(((
871 HSW1791
872 )))|(% colspan="1" style="width:282px" %)(((
873 Network status of the Ethernet2 connection server
874 )))|(% style="width:452px" %)(((
875 ~= 0, connection to the server is abnormal = 1, connection to the server is normal
876 )))
877 |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms.
878 |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)(((
879 * =0: db database
880 * =1: CSV
881
882 (Only valid for script function DbToCsvFile)
883 )))
884 |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)(((
885 * =0: use the old high-low word conversion (default)
886 * =1: usie the new high-low word conversion
887 )))
888 |=(% style="width: 160px;" %)HSW1855|(% style="width:282px" %)Screen Lock prompt display control|(% style="width:452px" %)(((
889 Control whether the screen lock prompt is displayed,
890
891 * =0: display(default value)
892 * =Other: no display.
893 )))
894 |=(% style="width: 160px;" %)HSW1856|(% style="width:282px" %)Display map fence drawing status|(% style="width:452px" %)(((
895 * =0: no map fence
896 * =1: The map fence is drawn and the device is inside the fence
897 * =2: The map fence is drawn and the device is outside the fence
898 )))
899 |=(% style="width: 160px;" %)HSW1857|(% style="width:282px" %)USB disk download |(% style="width:452px" %)(((
900 * =0: download project
901 * =1: download firmware
902 * =2: enter the background
903 )))
904 |=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)(((
905 * =0: priority Ethernet
906 * =1: priority WLAN
907 * =2: priority 4G
908 )))
909 |=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)(((
910 * =0: delete;
911 * = Others: do not delete
912 )))
913 |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
914 Monitor address is set during reset of reset switch, whether to cancel reset,
915
916 * = 0: yes (default);
917 * = 1: no
918 )))
919 |=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)(((
920 Controls whether the button pops up when double-clicking or long pressing on record type table object
921
922 * = 0: yes (default);
923 * = 1: no
924 )))
925 |=(% style="width: 160px;" %)(((
926 HSW1869
927 )))|(% style="width:282px" %)(((
928 Dynamic screensaver countdown
929 )))|(% style="width:452px" %)(((
930 Countdown to enter dynamic screensaver effect, unit (S)
931 )))
932 |=(% style="width: 160px;" %)(((
933 HSW1870
934 )))|(% style="width:282px" %)(((
935 Display or set the dynamic or static IP mode of Ethernet1
936 )))|(% style="width:452px" %)(((
937 HSX1870.0 = 0, Static IP mode
938
939 HSX1870.0 = 1, dynamic IP mode
940 )))
941 |=(% style="width: 160px;" %)(((
942 HSW1871
943 )))|(% style="width:282px" %)(((
944 Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1
945 )))|(% style="width:452px" %)(((
946 ~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
947 )))
948 |=(% style="width: 160px;" %)(((
949 HSW1872
950 )))|(% colspan="1" rowspan="8" style="width:282px" %)(((
951 ①Display and modify DNS1 and DNS2 of Ethernet1
952
953 ②Related registers can be read and written mode (only static IP mode can be written)
954 )))|(% style="width:452px" %)(((
955 Ethernet1 Local DNS1 address high byte 1
956 )))
957 |=(% style="width: 160px;" %)(((
958 HSW1873
959 )))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2
960 |=(% style="width: 160px;" %)(((
961 HSW1874
962 )))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3
963 |=(% style="width: 160px;" %)(((
964 HSW1875
965 )))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4
966 |=(% style="width: 160px;" %)(((
967 HSW1876
968 )))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1
969 |=(% style="width: 160px;" %)(((
970 HSW1877
971 )))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2
972 |=(% style="width: 160px;" %)(((
973 HSW1878
974 )))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3
975 |=(% style="width: 160px;" %)(((
976 HSW1879
977 )))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4
978 |=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)(((
979 * =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval)
980 * =Others: not refresh
981 )))
982 |=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data  |(% style="width:452px" %)(((
983 * =1, not clear screen cache when switch language
984 * =2, trigger clear cache of all screens for once time
985 * =3, always clear cache of all screen data
986 )))
987 |=(% style="width: 160px;" %)HSW1892|(% colspan="1" style="width:282px" %)Keyboard key polling interval setting|(% style="width:452px" %)(((
988 ~=0,50ms;
989
990 ~=1,40ms;
991
992 ~=2,30ms;
993
994 ~=3,20ms;
995
996 ~=4,10ms;
997 )))
998 |=(% style="width: 160px;" %)HSW1893|(% colspan="1" style="width:282px" %)Cursor mode switch|(% style="width:452px" %)(((
999 ~=0, default free mode;
1000
1001 ~=1, selected box mode;
1002
1003 ~=2, selected gray mode;
1004
1005 ~=3, mouse selected mode;
1006 )))
1007 |=(% style="width: 160px;" %)HSW1894|(% colspan="1" style="width:282px" %)Enable a specific serial keyboard|(% style="width:452px" %)(((
1008 ~=1 Enable;
1009
1010 ~=Other, not enabled;
1011
1012 Note: Only valid for initialization, recommended to use in background initialization script;
1013 )))
1014 |=(% style="width: 160px;" %)HSW1895|(% colspan="1" style="width:282px" %)Controls whether keyboard keys are effective in certain situations|(% style="width:452px" %)(((
1015 ~=0, by default, the key trigger does not take effect when the screen is off or in screen saver mode;
1016
1017 ~=1, HSX1895.0=1, the key trigger will also take effect when the screen is off;
1018
1019 ~=2, HSX1895.1=1, the key trigger will also take effect in screen saver mode;
1020 )))
1021 |=(% style="width: 160px;" %)HSW1903|(% colspan="1" style="width:282px" %)Check the network cable connection status|(% style="width:452px" %)If a network cable is detected, it is set to 1; if no network cable is detected, it is set to 0
1022 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
1023 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
1024 Note: Valid when Ethernet1 of HMI is plugged into the network cable.
1025 ① When the Ethernet setting is enabled in the project parameters, this register displays the set value.
1026 ② When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
1027 ③ When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
1028 ④ IP related registers can be read and written (only static IP mode can be written).
1029 )))|(% style="width:452px" %)Local IP address high byte 1
1030 |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2
1031 |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3
1032 |=(% style="width: 160px;" %)HSW10038|(% style="width:452px" %)Local IP address high byte 4
1033 |=(% style="width: 160px;" %)HSW10039|(% style="width:452px" %)Local mask IP address high byte 1
1034 |=(% style="width: 160px;" %)HSW10040|(% style="width:452px" %)Local mask IP address high byte 2
1035 |=(% style="width: 160px;" %)HSW10041|(% style="width:452px" %)Local mask IP address high byte 3
1036 |=(% style="width: 160px;" %)HSW10042|(% style="width:452px" %)Local mask IP address high byte 4
1037 |=(% style="width: 160px;" %)HSW10043|(% style="width:452px" %)Local gateway address high byte 1
1038 |=(% style="width: 160px;" %)HSW10044|(% style="width:452px" %)Local gateway address high byte 2
1039 |=(% style="width: 160px;" %)HSW10045|(% style="width:452px" %)Local gateway address high byte 3
1040 |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4
1041 |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address
1042 |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)(((
1043 ①Display the MAC code of Ethernet1 NIC
1044
1045 (hexadecimal display)
1046
1047 ②Read-only mode, not modifiable
1048 )))|(% style="width:452px" %)Local MAC code high word 1
1049 |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2
1050 |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3
1051 |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4
1052 |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5
1053 |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6
1054 |=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
1055 |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
1056 |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password
1057 |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit)
1058 |=(% style="width: 160px;" %)HSW10576|(% style="width:282px" %)Save dynamic installment settings|(% style="width:452px" %)HSX10576.0=1: Save the set dynamic installment information
1059 |=(% style="width: 160px;" %)HSW10577|(% style="width:282px" %)Control address for installment|(% style="width:452px" %)(((
1060 * HSX10577.0=0: disable dynamic installment
1061 * HSX10577.0=1: enable dynamic installment
1062 * HSX10577.1=0: disable static installment
1063 * HSX10577.1=1: enable static installment
1064 )))
1065 |=(% style="width: 160px;" %)HSW10578-10583|(% style="width:282px" %)Password for dynamic installment|(% style="width:452px" %)Character Input/ Display (length: 6)
1066 |=(% style="width: 160px;" %)HSW10584-10586|(% style="width:282px" %)Expiry time of dynamic installment|(% style="width:452px" %)Expiry time: YYYYMMDD (Numeric Input/ Display)
1067 |=(% style="width: 160px;" %)HSW10587-10589|(% style="width:282px" %)Last expiry time of dynamic installment|(% style="width:452px" %)Expiry time: YYYYMMDD (Numeric Input/ Display)
1068 |=(% style="width: 160px;" %)HSW10590|(% style="width:282px" %)Background light time|(% style="width:452px" %)(((
1069 Set the light time for background
1070
1071 * =0: The screen backlight is always on.
1072 * =Others: The screen backlight is on for a period of time and then turns off. The length of time is controlled by the value of the register address. Unit: second.
1073 )))
1074 |=(% style="width: 160px;" %)HSW10591|(% style="width:282px" %)Backlight brightness adjustment|(% style="width:452px" %)Backlight brightness range: 1 (darkest) ~~ 100 (brightest)
1075 |=(% style="width: 160px;" %)HSW10603|(% style="width:282px" %)Set the printer to print orientation|(% style="width:452px" %)(((
1076 Set the print direction:
1077
1078 * =1: Forward printing
1079 * =2: Reverse print
1080 * =Other: Forward print
1081 )))
1082 |=(% style="width: 160px;" %)HSW10604|(% style="width:282px" %)Print dot type|(% style="width:452px" %)(((
1083 * =1: new firmware 8 dot matrix type
1084 * =2: new firmware 24 dot matrix type
1085 * =3: old firmware 8 dot matrix type
1086 * =4: old firmware 24 dot matrix type
1087 * =Other: new firmware 8 dot matrix type
1088 )))
1089 |=(% style="width: 160px;" %)HSW10605|(% style="width:282px" %)Print width of printer|(% style="width:452px" %)Set the width of the printer to print (in pixels), such as HSW10605 = 394: The printer supports images with a print width of 394 pixels
1090 |=(% style="width: 160px;" %)HSW10606|(% style="width:282px" %)Printer instruction type|(% style="width:452px" %)(((
1091 * =1: Graphic print type
1092 * =2: Dot density printing type
1093 * =3(Default value): special for EPSON printer
1094 )))
1095 |=(% style="width: 160px;" %)HSW10607|(% style="width:282px" %)Printer paper cutting function|(% style="width:452px" %)(((
1096 * =1: Enable
1097 * =2: Disable
1098 )))
1099 |=(% style="width: 160px;" %)HSW10608|(% style="width:282px" %)Print the alignment of the text|(% style="width:452px" %)(((
1100 * =1: Left alignment
1101 * =2: Center alignment
1102 * =3: Right alignment
1103 )))
1104 |=(% style="width: 160px;" %)HSW10611|(% style="width:282px" %)Set weconcloud server|(% style="width:452px" %)(((
1105 * =0: Select the server configured in "Project Settings"
1106 * =1: select Server 1
1107 * =2: select Server 2
1108 )))
1109 |=(% style="width: 160px;" %)HSW11750|(% style="width:282px" %)Set the language of the Message List prompt** (ie series)**|(% style="width:452px" %)(((
1110 * =0: which is followed the project language
1111 * =1: English
1112 * =2: Chinese
1113 )))
1114 |=(% style="width: 160px;" %)HSW11752|(% style="width:282px" %)Traffic monitoring control|(% style="width:452px" %)= 1: Enable the flow monitoring function
1115 ~= Other: Disable the flow monitoring function
1116 |=(% style="width: 160px;" %)HSW11753|(% style="width:282px" %)Traffic monitoring network card type|(% style="width:452px" %)= 0: Ethernet card
1117 ~= 1: 4G
1118 ~= 2: Wi-Fi
1119 |=(% style="width: 160px;" %)HSW11754-11755|(% style="width:282px" %)Historical traffic consumption|(% style="width:452px" %)The total traffic consumed historically (bytes) [value is an integer]
1120 |=(% style="width: 160px;" %)HSW11756|(% style="width:282px" %)(((
1121 Access permission restrictions
1122
1123 (ig series and** **8000/9000 series with -R after system upgrade)
1124 )))|(% style="width:452px" %)(((
1125 * =0: LAN or the external network both OK
1126 * =1: Only LAN access
1127 * =2: Only external network can access
1128 * =3: Close the functions
1129 )))
1130 |=(% style="width: 160px;" %)HSW11757|(% style="width:282px" %)Enable the valid date of the dynamic installment password|(% style="width:452px" %)(((
1131 * =0: Disabled
1132 * =1: Enable
1133 )))
1134 |=(% style="width: 160px;" %)HSW11758|(% style="width:282px" %)Enable Screensaver|(% style="width:452px" %)(((
1135 * =0: Disabled
1136 * =1: Enable
1137 )))
1138 |=(% style="width: 160px;" %)HSW11759|(% style="width:282px" %)Screensaver interval time|(% style="width:452px" %)(((
1139 Set the time how long will enter Screensaver (Range 10~~43200s)
1140 )))
1141 |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second.
1142 |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver
1143 |=(% style="width: 160px;" %)(((
1144 HSW11762
1145 )))|(% style="width:282px" %)(((
1146 Dynamic screensaver control address
1147 )))|(% style="width:452px" %)(((
1148 HSX11762.0=0, initialize with project configuration;
1149
1150 HSX11762.0=1, initialize with special register configuration;
1151
1152 HSX11762.1=0, disable dynamic screensaver;
1153
1154 HSX11762.1=1, enable dynamic screensaver
1155 )))
1156 |=(% style="width: 160px;" %)(((
1157 HSW11763
1158 )))|(% style="width:282px" %)(((
1159 Waiting time to enter the dynamic screensaver
1160 )))|(% style="width:452px" %)(((
1161 Waiting time when the screen is not operated, range 1~~720 minutes
1162 )))
1163 |=(% style="width: 160px;" %)(((
1164 HSW11764
1165 )))|(% style="width:282px" %)(((
1166 Animated screensaver animation type
1167 )))|(% style="width:452px" %)(((
1168 ~=0: Raster,=1: Blinds,=2: Bubble
1169 )))
1170 |=(% style="width: 160px;" %)HSW11767|(% style="width:282px" %)Remote screen display adaptation mode switching|(% style="width:452px" %)=0, default mode, remote full-screen zoom display for horizontal screen projects, remote proportional zoom display for vertical screen projects;
1171 ~=1, full-screen zoom display;
1172 ~=2, proportional zoom display according to screen size ratio;
1173 ~=3, no zoom display according to screen pixels;
1174 |=(% style="width: 160px;" %)HSW11773|(% style="width:282px" %)Automatically log out user control address|(% style="width:452px" %)=3: that is, HSX11773.0=1, HSX11773.1=1, based on the configuration in the address, enable automatic user logout.
1175 |=(% style="width: 160px;" %)HSW11774|(% style="width:282px" %)Automatic user logout interval|(% style="width:452px" %)(((
1176 Range: 1 to 255
1177
1178 Unit: Minutes
1179 )))
1180 |=(% style="width: 160px;" %)HSW11815|(% style="width:282px" %)Sub-screen drag function (For PI10.4 and above)|(% style="width:452px" %)(((
1181 * =0: Disabled
1182 * =1: Enable
1183 )))
1184 |=(% style="width: 160px;" %)HSW11816|(% style="width:282px" %)Recipe record component button spacing control|(% style="width:452px" %)This controls the spacing between the top and bottom rows of buttons in all recipe record widgets. The value is the pixel spacing between the buttons. The minimum value is 0, and the maximum value is calculated based on the width of each recipe widget. The spacing plus the button size must not exceed the widget's size. (Note that if the register is greater than the maximum value, the actual spacing is the maximum spacing.)
1185
1186 == Serial port communication configuration ==
1187
1188 (% class="table-bordered" %)
1189 |=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
1190 |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)(((
1191 * =0: RS232
1192 * =1: RS485
1193 * =2: RS422
1194 )))
1195 |(% style="width:173px" %)Baud rate|(% style="width:122px" %)HSW10062|(% colspan="2" style="width:506px" %)(((
1196 * =0: 1200
1197 * =1: 2400
1198 * =2: 4800
1199 * =3: 9600
1200 * =4: 19200
1201 * =5: 38400
1202 * =6: 57600
1203 * =7: 115200
1204 * =8: 187500
1205 * =9: 230400
1206 )))
1207 |(% style="width:173px" %)Data bit|(% style="width:122px" %)HSW10063|(% colspan="2" style="width:506px" %)(((
1208 * =7: 7 bit
1209 * =8: 8 bit
1210 )))
1211 |(% style="width:173px" %)Stop bit|(% style="width:122px" %)HSW10064|(% colspan="2" style="width:506px" %)(((
1212 * =1: 1 bit
1213 * =2: 2 bit
1214 )))
1215 |(% style="width:173px" %)Check bit|(% style="width:122px" %)HSW10065|(% colspan="2" style="width:506px" %)(((
1216 * =0: None
1217 * =1: ODD
1218 * =2: EVEN
1219 )))
1220 |(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)(((
1221 * Unit: ms.
1222 * Range: 0 to 30000
1223 )))
1224 |(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)(((
1225 * Unit: ms.
1226 * Range: 0 to 30000
1227 )))
1228 |(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)(((
1229 * Unit: times.
1230 * Range: 0 to 100
1231 )))
1232 |(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)(((
1233 * Unit: s.
1234 * Range: 0 to 300
1235 )))
1236 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %)
1237 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %)
1238 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)(((
1239 * =0: RS232
1240 * =1: RS485
1241 * =2: RS422
1242 * =6: RS485-2
1243 )))
1244 |(% style="width:173px" %)Baud rate|(% style="width:122px" %)HSW10095|(% colspan="2" style="width:506px" %)(((
1245 * =0: 1200
1246 * =1: 2400
1247 * =2: 4800
1248 * =3: 9600
1249 * =4: 19200
1250 * =5: 38400
1251 * =6: 57600
1252 * =7: 115200
1253 * =8: 230400
1254 )))
1255 |(% style="width:173px" %)Data bit|(% style="width:122px" %)HSW10096|(% colspan="2" style="width:506px" %)(((
1256 * =7: 7 bit
1257 * =8: 8 bit
1258 )))
1259 |(% style="width:173px" %)Stop bit|(% style="width:122px" %)HSW10097|(% colspan="2" style="width:506px" %)(((
1260 * =1: 1 bit
1261 * =2: 2 bit
1262 )))
1263 |(% style="width:173px" %)Check bit|(% style="width:122px" %)HSW10098|(% colspan="2" style="width:506px" %)(((
1264 * =0: None
1265 * =1: ODD
1266 * =2: EVEN
1267 )))
1268 |(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)(((
1269 * Unit: ms.
1270 * Range: 0 to 30000
1271 )))
1272 |(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)(((
1273 * Unit: ms.
1274 * Range: 0 to 30000
1275 )))
1276 |(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)(((
1277 * Unit: times.
1278 * Range: 0 to 100
1279 )))
1280 |(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)(((
1281 * Unit: s.
1282 * Range: 0 to 30
1283 )))
1284 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %)
1285 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %)
1286 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)(((
1287 * =0: RS232
1288 * =1: RS485
1289 * =2: RS422
1290 * =6: RS485-2
1291 )))
1292 |(% style="width:173px" %)Baud rate|(% style="width:122px" %)HSW10121|(% colspan="2" style="width:506px" %)(((
1293 * =0: 1200
1294 * =1: 2400
1295 * =2: 4800
1296 * =3: 9600
1297 * =4: 19200
1298 * =5: 38400
1299 * =6: 57600
1300 * =7: 115200
1301 * =8: 230400
1302 )))
1303 |(% style="width:173px" %)Data bit|(% style="width:122px" %)HSW10122|(% colspan="2" style="width:506px" %)(((
1304 * =7: 7 bit
1305 * =8: 8 bit
1306 )))
1307 |(% style="width:173px" %)Stop bit|(% style="width:122px" %)HSW10123|(% colspan="2" style="width:506px" %)(((
1308 * =1: 1 bit
1309 * =2: 2 bit
1310 )))
1311 |(% style="width:173px" %)Check bit|(% style="width:122px" %)HSW10124|(% colspan="2" style="width:506px" %)(((
1312 * =0: None
1313 * =1: ODD
1314 * =2: EVEN
1315 )))
1316 |(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)(((
1317 * Unit: ms.
1318 * Range: 0 to 30000
1319 )))
1320 |(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)(((
1321 * Unit: ms.
1322 * Range: 0 to 30000
1323 )))
1324 |(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)(((
1325 * Unit: times.
1326 * Range: 0 to 100
1327 )))
1328 |(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)(((
1329 * Unit: s.
1330 * Range: 0 to 30
1331 )))
1332 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %)
1333 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %)
1334 |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)(((
1335 * =0: RS232
1336 * =1: RS485
1337 )))
1338 |(% style="width:173px" %)Baud rate|(% style="width:122px" %)HSW10073|(% colspan="2" style="width:506px" %)(((
1339 * =0: 1200
1340 * =1: 2400
1341 * =2: 4800
1342 * =3: 9600
1343 * =4: 19200
1344 * =5: 38400
1345 * =6: 57600
1346 * =7: 115200
1347 * =8: 230400
1348 )))
1349 |(% style="width:173px" %)Data bit|(% style="width:122px" %)HSW10074|(% colspan="2" style="width:506px" %)(((
1350 * =7: 7 bit
1351 * =8: 8 bit
1352 )))
1353 |(% style="width:173px" %)Stop bit|(% style="width:122px" %)HSW10075|(% colspan="2" style="width:506px" %)(((
1354 * =1: 1 bit
1355 * =2: 2 bit
1356 )))
1357 |(% style="width:173px" %)Check bit|(% style="width:122px" %)HSW10076|(% colspan="2" style="width:506px" %)(((
1358 * =0: None
1359 * =1: ODD
1360 * =2: EVEN
1361 )))
1362 |(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)(((
1363 * Unit: ms.
1364 * Range: 0 to 30000
1365 )))
1366 |(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)(((
1367 * Unit: ms.
1368 * Range: 0 to 30000
1369 )))
1370 |(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)(((
1371 * Unit: times.
1372 * Range: 0 to 100
1373 )))
1374 |(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)(((
1375 * Unit: s.
1376 * Range: 0 to 30
1377 )))
1378 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %)
1379 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %)
1380 |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)(((
1381 * =0: RS232
1382 * =1: RS485
1383 )))
1384 |(% style="width:173px" %)Baud rate|(% style="width:122px" %)HSW10106|(% colspan="2" style="width:506px" %)(((
1385 * =0: 1200
1386 * =1: 2400
1387 * =2: 4800
1388 * =3: 9600
1389 * =4: 19200
1390 * =5: 38400
1391 * =6: 57600
1392 * =7: 115200
1393 * =8: 230400
1394 )))
1395 |(% style="width:173px" %)Data bit|(% style="width:122px" %)HSW10107|(% colspan="2" style="width:506px" %)(((
1396 * =7: 7 bit
1397 * =8: 8 bit
1398 )))
1399 |(% style="width:173px" %)Stop bit|(% style="width:122px" %)HSW10108|(% colspan="2" style="width:506px" %)(((
1400 * =1: 1 bit
1401 * =2: 2 bit
1402 )))
1403 |(% style="width:173px" %)Check bit|(% style="width:122px" %)HSW10109|(% colspan="2" style="width:506px" %)(((
1404 * =0: None
1405 * =1: ODD
1406 * =2: EVEN
1407 )))
1408 |(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)(((
1409 * Unit: ms.
1410 * Range: 0 to 30000
1411 )))
1412 |(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)(((
1413 * Unit: ms.
1414 * Range: 0 to 30000
1415 )))
1416 |(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)(((
1417 * Unit: times.
1418 * Range: 0 to 100
1419 )))
1420 |(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)(((
1421 * Unit: s.
1422 * Range: 0 to 30
1423 )))
1424 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %)
1425 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %)
1426 |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)(((
1427 * =1: RS485
1428 )))
1429 |(% style="width:173px" %)Baud rate|(% style="width:122px" %)HSW10084|(% colspan="2" style="width:506px" %)(((
1430 * =0: 1200
1431 * =1: 2400
1432 * =2: 4800
1433 * =3: 9600
1434 * =4: 19200
1435 * =5: 38400
1436 * =6: 57600
1437 * =7: 115200
1438 * =8: 230400
1439 )))
1440 |(% style="width:173px" %)Data bit|(% style="width:122px" %)HSW10085|(% colspan="2" style="width:506px" %)(((
1441 * =7: 7 bit
1442 * =8: 8 bit
1443 )))
1444 |(% style="width:173px" %)Stop bit|(% style="width:122px" %)HSW10086|(% colspan="2" style="width:506px" %)(((
1445 * =1: 1 bit
1446 * =2: 2 bit
1447 )))
1448 |(% style="width:173px" %)Check bit|(% style="width:122px" %)HSW10087|(% colspan="2" style="width:506px" %)(((
1449 * =0: None
1450 * =1: ODD
1451 * =2: EVEN
1452 )))
1453 |(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)(((
1454 * Unit: ms.
1455 * Range: 0 to 30000
1456 )))
1457 |(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)(((
1458 * Unit: ms.
1459 * Range: 0 to 30000
1460 )))
1461 |(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)(((
1462 * Unit: times.
1463 * Range: 0 to 100
1464 )))
1465 |(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)(((
1466 * Unit: s.
1467 * Range: 0 to 30
1468 )))
1469 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %)
1470 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %)
1471 |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)(((
1472 Unit: K, the baud rate must be an integer.
1473
1474 For example, when the baud rate required is 250000, just enter 250.
1475 )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect.
1476 |(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)(((
1477 Unit: K, the baud rate must be an integer.
1478
1479 For example, when the baud rate required is 250000, just enter 250.
1480 )))
1481
1482 == Ethernet communication configuration ==
1483
1484 (% class="table-bordered" %)
1485 |(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description**
1486 |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1
1487 |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2
1488 |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3
1489 |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4
1490 |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number
1491 |(% style="width:220px" %)HSW11009|(% style="width:336px" %)(((
1492 ~=2 TCP
1493
1494 ~=3 UDP
1495 )))
1496 |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved
1497 |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1
1498 |(% style="width:220px" %)HSW11012|(% style="width:336px" %)Device IP address high word 2
1499 |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3
1500 |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4
1501 |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number
1502 |(% style="width:220px" %)HSW11016|(% style="width:336px" %)(((
1503 ~=2 TCP
1504
1505 ~=3 UDP
1506 )))
1507 |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved
1508 |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)…
1509 |(% rowspan="7" style="width:40px" %)32|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 32 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11221|(% style="width:336px" %)Device IP address high word 1
1510 |(% style="width:220px" %)HSW11222|(% style="width:336px" %)Device IP address high word 2
1511 |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3
1512 |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4
1513 |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number
1514 |(% style="width:220px" %)HSW11226|(% style="width:336px" %)(((
1515 ~=2 TCP;
1516
1517 ~=3 UDP
1518 )))
1519 |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved
1520
1521 (% class="box infomessage" %)
1522 (((
1523 **✎Note:** The number of Ethernet connections supported by different HMI series varies.
1524 )))
1525
1526 == Communication control ==
1527
1528 (% class="table-bordered" %)
1529 |=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**
1530 |(% colspan="1" rowspan="16" style="width:135px" %)1|(% style="width:102px" %)0~~15|(% style="width:185px" %)HSX550.0~HSX550.15|(% style="width:191px" %)HSX558.0~HSX558.15|(% rowspan="160" style="width:271px" %)Communication number refers to the number in "Communication Port Configuration". A number provides 256 device station numbers. Each station number corresponds to a communication control bit and a communication indicator bit. Registers HSX550.0 to HSX805.15 are used to control the station numbers from 0 to 127, and registers HSX1150.0 to HSX1405.15 are used to control station numbers 128 to 255.
1531 |(% style="width:102px" %)16~~31|(% style="width:185px" %)HSX551.0~HSX551.15|(% style="width:191px" %)HSX559.0~HSX559.15
1532 |(% style="width:102px" %)32~~47|(% style="width:185px" %)HSX552.0~HSX552.15|(% style="width:191px" %)HSX560.0~HSX560.15
1533 |(% style="width:102px" %)48~~63|(% style="width:185px" %)HSX553.0~HSX553.15|(% style="width:191px" %)HSX561.0~HSX561.15
1534 |(% style="width:102px" %)64~79|(% style="width:185px" %)HSX554.0~HSX554.15|(% style="width:191px" %)HSX562.0~HSX562.15
1535 |(% style="width:102px" %)80~95|(% style="width:185px" %)HSX555.0~HSX555.15|(% style="width:191px" %)HSX563.0~HSX563.15
1536 |(% style="width:102px" %)96~111|(% style="width:185px" %)HSX556.0~HSX556.15|(% style="width:191px" %)HSX564.0~HSX564.15
1537 |(% style="width:102px" %)112~127|(% style="width:185px" %)HSX557.0~HSX557.15|(% style="width:191px" %)HSX565.0~HSX565.15
1538 |(% style="width:102px" %)128~143|(% style="width:185px" %)HSX1150.0~HSX1150.15|(% style="width:191px" %)HSX1158.0~HSX1158.15
1539 |(% style="width:102px" %)144~159|(% style="width:185px" %)HSX1151.0~HSX1151.15|(% style="width:191px" %)HSX1159.0~HSX1159.15
1540 |(% style="width:102px" %)160~175|(% style="width:185px" %)HSX1152.0~HSX1152.15|(% style="width:191px" %)HSX1160.0~HSX1160.15
1541 |(% style="width:102px" %)176~191|(% style="width:185px" %)HSX1153.0~HSX1153.15|(% style="width:191px" %)HSX1161.0~HSX1161.15
1542 |(% style="width:102px" %)192~207|(% style="width:185px" %)HSX1154.0~HSX1154.15|(% style="width:191px" %)HSX1162.0~HSX1162.15
1543 |(% style="width:102px" %)208~223|(% style="width:185px" %)HSX1155.0~HSX1155.15|(% style="width:191px" %)HSX1163.0~HSX1163.15
1544 |(% style="width:102px" %)224~239|(% style="width:185px" %)HSX1156.0~HSX1156.15|(% style="width:191px" %)HSX1164.0~HSX1164.15
1545 |(% style="width:102px" %)240~255|(% style="width:185px" %)HSX1157.0~HSX1157.15|(% style="width:191px" %)HSX1165.0~HSX1165.15
1546 |(% colspan="1" rowspan="16" style="width:135px" %)2|(% style="width:102px" %)0~15|(% style="width:185px" %)HSX566.0~HSX566.15|(% style="width:191px" %)HSX574.0~HSX574.15
1547 |(% style="width:102px" %)16~31|(% style="width:185px" %)HSX567.0~HSX567.15|(% style="width:191px" %)HSX575.0~HSX575.15
1548 |(% style="width:102px" %)32~47|(% style="width:185px" %)HSX568.0~HSX568.15|(% style="width:191px" %)HSX576.0~HSX576.15
1549 |(% style="width:102px" %)48~63|(% style="width:185px" %)HSX569.0~HSX569.15|(% style="width:191px" %)HSX577.0~HSX577.15
1550 |(% style="width:102px" %)64~79|(% style="width:185px" %)HSX570.0~HSX570.15|(% style="width:191px" %)HSX578.0~HSX578.15
1551 |(% style="width:102px" %)80~95|(% style="width:185px" %)HSX571.0~HSX571.15|(% style="width:191px" %)HSX579.0~HSX579.15
1552 |(% style="width:102px" %)96~111|(% style="width:185px" %)HSX572.0~HSX572.15|(% style="width:191px" %)HSX580.0~HSX580.15
1553 |(% style="width:102px" %)112~127|(% style="width:185px" %)HSX573.0~HSX573.15|(% style="width:191px" %)HSX581.0~HSX581.15
1554 |(% style="width:102px" %)128~143|(% style="width:185px" %)HSX1166.0~HSX1166.15|(% style="width:191px" %)HSX1174.0~HSX1174.15
1555 |(% style="width:102px" %)144~159|(% style="width:185px" %)HSX1167.0~HSX1167.15|(% style="width:191px" %)HSX1175.0~HSX1175.15
1556 |(% style="width:102px" %)160~175|(% style="width:185px" %)HSX1168.0~HSX1168.15|(% style="width:191px" %)HSX1176.0~HSX1176.15
1557 |(% style="width:102px" %)176~191|(% style="width:185px" %)HSX1169.0~HSX1169.15|(% style="width:191px" %)HSX1177.0~HSX1177.15
1558 |(% style="width:102px" %)192~207|(% style="width:185px" %)HSX1170.0~HSX1170.15|(% style="width:191px" %)HSX1178.0~HSX1178.15
1559 |(% style="width:102px" %)208~223|(% style="width:185px" %)HSX1171.0~HSX1171.15|(% style="width:191px" %)HSX1179.0~HSX1179.15
1560 |(% style="width:102px" %)224~239|(% style="width:185px" %)HSX1172.0~HSX1172.15|(% style="width:191px" %)HSX1180.0~HSX1180.15
1561 |(% style="width:102px" %)240~255|(% style="width:185px" %)HSX1173.0~HSX1173.15|(% style="width:191px" %)HSX1181.0~HSX1181.15
1562 |(% colspan="1" rowspan="16" style="width:135px" %)3|(% style="width:102px" %)0~15|(% style="width:185px" %)HSX582.0~HSX582.15|(% style="width:191px" %)HSX590.0~HSX590.15
1563 |(% style="width:102px" %)16~31|(% style="width:185px" %)HSX583.0~HSX583.15|(% style="width:191px" %)HSX591.0~HSX591.15
1564 |(% style="width:102px" %)32~47|(% style="width:185px" %)HSX584.0~HSX584.15|(% style="width:191px" %)HSX592.0~HSX592.15
1565 |(% style="width:102px" %)48~63|(% style="width:185px" %)HSX585.0~HSX585.15|(% style="width:191px" %)HSX593.0~HSX593.15
1566 |(% style="width:102px" %)64~79|(% style="width:185px" %)HSX586.0~HSX586.15|(% style="width:191px" %)HSX594.0~HSX594.15
1567 |(% style="width:102px" %)80~95|(% style="width:185px" %)HSX587.0~HSX587.15|(% style="width:191px" %)HSX595.0~HSX595.15
1568 |(% style="width:102px" %)96~111|(% style="width:185px" %)HSX588.0~HSX588.15|(% style="width:191px" %)HSX596.0~HSX596.15
1569 |(% style="width:102px" %)112~127|(% style="width:185px" %)HSX589.0~HSX589.15|(% style="width:191px" %)HSX597.0~HSX597.15
1570 |(% style="width:102px" %)128~143|(% style="width:185px" %)HSX1182.0~HSX1182.15|(% style="width:191px" %)HSX1190.0~HSX1190.15
1571 |(% style="width:102px" %)144~159|(% style="width:185px" %)HSX1183.0~HSX1183.15|(% style="width:191px" %)HSX1191.0~HSX1191.15
1572 |(% style="width:102px" %)160~175|(% style="width:185px" %)HSX1184.0~HSX1184.15|(% style="width:191px" %)HSX1192.0~HSX1192.15
1573 |(% style="width:102px" %)176~191|(% style="width:185px" %)HSX1185.0~HSX1185.15|(% style="width:191px" %)HSX1193.0~HSX1193.15
1574 |(% style="width:102px" %)192~207|(% style="width:185px" %)HSX1186.0~HSX1186.15|(% style="width:191px" %)HSX1194.0~HSX1194.15
1575 |(% style="width:102px" %)208~223|(% style="width:185px" %)HSX1187.0~HSX1187.15|(% style="width:191px" %)HSX1195.0~HSX1195.15
1576 |(% style="width:102px" %)224~239|(% style="width:185px" %)HSX1188.0~HSX1188.15|(% style="width:191px" %)HSX1196.0~HSX1196.15
1577 |(% style="width:102px" %)240~255|(% style="width:185px" %)HSX1189.0~HSX1189.15|(% style="width:191px" %)HSX1197.0~HSX1197.15
1578 |(% colspan="1" rowspan="16" style="width:135px" %)4|(% style="width:102px" %)0~15|(% style="width:185px" %)HSX598.0~HSX598.15|(% style="width:191px" %)HSX606.0~HSX606.15
1579 |(% style="width:102px" %)16~31|(% style="width:185px" %)HSX599.0~HSX599.15|(% style="width:191px" %)HSX607.0~HSX607.15
1580 |(% style="width:102px" %)32~47|(% style="width:185px" %)HSX600.0~HSX600.15|(% style="width:191px" %)HSX608.0~HSX608.15
1581 |(% style="width:102px" %)48~63|(% style="width:185px" %)HSX601.0~HSX601.15|(% style="width:191px" %)HSX609.0~HSX609.15
1582 |(% style="width:102px" %)64~79|(% style="width:185px" %)HSX602.0~HSX602.15|(% style="width:191px" %)HSX610.0~HSX610.15
1583 |(% style="width:102px" %)80~95|(% style="width:185px" %)HSX603.0~HSX603.15|(% style="width:191px" %)HSX611.0~HSX611.15
1584 |(% style="width:102px" %)96~111|(% style="width:185px" %)HSX604.0~HSX604.15|(% style="width:191px" %)HSX612.0~HSX612.15
1585 |(% style="width:102px" %)112~127|(% style="width:185px" %)HSX605.0~HSX605.15|(% style="width:191px" %)HSX613.0~HSX613.15
1586 |(% style="width:102px" %)128~143|(% style="width:185px" %)HSX1198.0~HSX1198.15|(% style="width:191px" %)HSX1206.0~HSX1206.15
1587 |(% style="width:102px" %)144~159|(% style="width:185px" %)HSX1199.0~HSX1199.15|(% style="width:191px" %)HSX1207.0~HSX1207.15
1588 |(% style="width:102px" %)160~175|(% style="width:185px" %)HSX1200.0~HSX1200.15|(% style="width:191px" %)HSX1208.0~HSX1208.15
1589 |(% style="width:102px" %)176~191|(% style="width:185px" %)HSX1201.0~HSX1201.15|(% style="width:191px" %)HSX1209.0~HSX1209.15
1590 |(% style="width:102px" %)192~207|(% style="width:185px" %)HSX1202.0~HSX1202.15|(% style="width:191px" %)HSX1210.0~HSX1210.15
1591 |(% style="width:102px" %)208~223|(% style="width:185px" %)HSX1203.0~HSX1203.15|(% style="width:191px" %)HSX1211.0~HSX1211.15
1592 |(% style="width:102px" %)224~239|(% style="width:185px" %)HSX1204.0~HSX1204.15|(% style="width:191px" %)HSX1212.0~HSX1212.15
1593 |(% style="width:102px" %)240~255|(% style="width:185px" %)HSX1205.0~HSX1205.15|(% style="width:191px" %)HSX1213.0~HSX1213.15
1594 |(% colspan="1" rowspan="16" style="width:135px" %)5|(% style="width:102px" %)0~15|(% style="width:185px" %)HSX614.0~HSX614.15|(% style="width:191px" %)HSX622.0~HSX622.15
1595 |(% style="width:102px" %)16~31|(% style="width:185px" %)HSX615.0~HSX615.15|(% style="width:191px" %)HSX623.0~HSX623.15
1596 |(% style="width:102px" %)32~47|(% style="width:185px" %)HSX616.0~HSX616.15|(% style="width:191px" %)HSX624.0~HSX624.15
1597 |(% style="width:102px" %)48~63|(% style="width:185px" %)HSX617.0~HSX617.15|(% style="width:191px" %)HSX625.0~HSX625.15
1598 |(% style="width:102px" %)64~79|(% style="width:185px" %)HSX618.0~HSX618.15|(% style="width:191px" %)HSX626.0~HSX626.15
1599 |(% style="width:102px" %)80~95|(% style="width:185px" %)HSX619.0~HSX619.15|(% style="width:191px" %)HSX627.0~HSX627.15
1600 |(% style="width:102px" %)96~111|(% style="width:185px" %)HSX620.0~HSX620.15|(% style="width:191px" %)HSX628.0~HSX628.15
1601 |(% style="width:102px" %)112~127|(% style="width:185px" %)HSX621.0~HSX621.15|(% style="width:191px" %)HSX629.0~HSX629.15
1602 |(% style="width:102px" %)128~143|(% style="width:185px" %)HSX1214.0~HSX1214.15|(% style="width:191px" %)HSX1222.0~HSX1222.15
1603 |(% style="width:102px" %)144~159|(% style="width:185px" %)HSX1215.0~HSX1215.15|(% style="width:191px" %)HSX1223.0~HSX1223.15
1604 |(% style="width:102px" %)160~175|(% style="width:185px" %)HSX1216.0~HSX1216.15|(% style="width:191px" %)HSX1224.0~HSX1224.15
1605 |(% style="width:102px" %)176~191|(% style="width:185px" %)HSX1217.0~HSX1217.15|(% style="width:191px" %)HSX1225.0~HSX1225.15
1606 |(% style="width:102px" %)192~207|(% style="width:185px" %)HSX1218.0~HSX1218.15|(% style="width:191px" %)HSX1226.0~HSX1226.15
1607 |(% style="width:102px" %)208~223|(% style="width:185px" %)HSX1219.0~HSX1219.15|(% style="width:191px" %)HSX1227.0~HSX1227.15
1608 |(% style="width:102px" %)224~239|(% style="width:185px" %)HSX1220.0~HSX1220.15|(% style="width:191px" %)HSX1228.0~HSX1228.15
1609 |(% style="width:102px" %)240~255|(% style="width:185px" %)HSX1221.0~HSX1221.15|(% style="width:191px" %)HSX1229.0~HSX1229.15
1610 |(% colspan="1" rowspan="16" style="width:135px" %)6|(% style="width:102px" %)0~15|(% style="width:185px" %)HSX630.0~HSX630.15|(% style="width:191px" %)HSX638.0~HSX638.15
1611 |(% style="width:102px" %)16~31|(% style="width:185px" %)HSX631.0~HSX631.15|(% style="width:191px" %)HSX639.0~HSX639.15
1612 |(% style="width:102px" %)32~47|(% style="width:185px" %)HSX632.0~HSX632.15|(% style="width:191px" %)HSX640.0~HSX640.15
1613 |(% style="width:102px" %)48~63|(% style="width:185px" %)HSX633.0~HSX633.15|(% style="width:191px" %)HSX641.0~HSX641.15
1614 |(% style="width:102px" %)64~79|(% style="width:185px" %)HSX634.0~HSX634.15|(% style="width:191px" %)HSX642.0~HSX642.15
1615 |(% style="width:102px" %)80~95|(% style="width:185px" %)HSX635.0~HSX635.15|(% style="width:191px" %)HSX643.0~HSX643.15
1616 |(% style="width:102px" %)96~111|(% style="width:185px" %)HSX636.0~HSX636.15|(% style="width:191px" %)HSX644.0~HSX644.15
1617 |(% style="width:102px" %)112~127|(% style="width:185px" %)HSX637.0~HSX637.15|(% style="width:191px" %)HSX645.0~HSX645.15
1618 |(% style="width:102px" %)128~143|(% style="width:185px" %)HSX1230.0~HSX1230.15|(% style="width:191px" %)HSX1238.0~HSX1238.15
1619 |(% style="width:102px" %)144~159|(% style="width:185px" %)HSX1231.0~HSX1231.15|(% style="width:191px" %)HSX1239.0~HSX1239.15
1620 |(% style="width:102px" %)160~175|(% style="width:185px" %)HSX1232.0~HSX1232.15|(% style="width:191px" %)HSX1240.0~HSX1240.15
1621 |(% style="width:102px" %)176~191|(% style="width:185px" %)HSX1233.0~HSX1233.15|(% style="width:191px" %)HSX1241.0~HSX1241.15
1622 |(% style="width:102px" %)192~207|(% style="width:185px" %)HSX1234.0~HSX1234.15|(% style="width:191px" %)HSX1242.0~HSX1242.15
1623 |(% style="width:102px" %)208~223|(% style="width:185px" %)HSX1235.0~HSX1235.15|(% style="width:191px" %)HSX1243.0~HSX1243.15
1624 |(% style="width:102px" %)224~239|(% style="width:185px" %)HSX1236.0~HSX1236.15|(% style="width:191px" %)HSX1244.0~HSX1244.15
1625 |(% style="width:102px" %)240~255|(% style="width:185px" %)HSX1237.0~HSX1237.15|(% style="width:191px" %)HSX1245.0~HSX1245.15
1626 |(% colspan="1" rowspan="16" style="width:135px" %)7|(% style="width:102px" %)0~15|(% style="width:185px" %)HSX646.0~HSX646.15|(% style="width:191px" %)HSX654.0~HSX654.15
1627 |(% style="width:102px" %)16~31|(% style="width:185px" %)HSX647.0~HSX647.15|(% style="width:191px" %)HSX655.0~HSX655.15
1628 |(% style="width:102px" %)32~47|(% style="width:185px" %)HSX648.0~HSX648.15|(% style="width:191px" %)HSX656.0~HSX656.15
1629 |(% style="width:102px" %)48~63|(% style="width:185px" %)HSX649.0~HSX649.15|(% style="width:191px" %)HSX657.0~HSX657.15
1630 |(% style="width:102px" %)64~79|(% style="width:185px" %)HSX650.0~HSX650.15|(% style="width:191px" %)HSX658.0~HSX658.15
1631 |(% style="width:102px" %)80~95|(% style="width:185px" %)HSX651.0~HSX651.15|(% style="width:191px" %)HSX659.0~HSX659.15
1632 |(% style="width:102px" %)96~111|(% style="width:185px" %)HSX652.0~HSX652.15|(% style="width:191px" %)HSX660.0~HSX660.15
1633 |(% style="width:102px" %)112~127|(% style="width:185px" %)HSX653.0~HSX653.15|(% style="width:191px" %)HSX661.0~HSX661.15
1634 |(% style="width:102px" %)128~143|(% style="width:185px" %)HSX1246.0~HSX1246.15|(% style="width:191px" %)HSX1254.0~HSX1254.15
1635 |(% style="width:102px" %)144~159|(% style="width:185px" %)HSX1247.0~HSX1247.15|(% style="width:191px" %)HSX1255.0~HSX1255.15
1636 |(% style="width:102px" %)160~175|(% style="width:185px" %)HSX1248.0~HSX1248.15|(% style="width:191px" %)HSX1256.0~HSX1256.15
1637 |(% style="width:102px" %)176~191|(% style="width:185px" %)HSX1249.0~HSX1249.15|(% style="width:191px" %)HSX1257.0~HSX1257.15
1638 |(% style="width:102px" %)192~207|(% style="width:185px" %)HSX1250.0~HSX1250.15|(% style="width:191px" %)HSX1258.0~HSX1258.15
1639 |(% style="width:102px" %)208~223|(% style="width:185px" %)HSX1251.0~HSX1251.15|(% style="width:191px" %)HSX1259.0~HSX1259.15
1640 |(% style="width:102px" %)224~239|(% style="width:185px" %)HSX1252.0~HSX1252.15|(% style="width:191px" %)HSX1260.0~HSX1260.15
1641 |(% style="width:102px" %)240~255|(% style="width:185px" %)HSX1253.0~HSX1253.15|(% style="width:191px" %)HSX1261.0~HSX1261.15
1642 |(% colspan="1" rowspan="16" style="width:135px" %)8|(% style="width:102px" %)0~15|(% style="width:185px" %)HSX662.0~HSX662.15|(% style="width:191px" %)HSX670.0~HSX670.15
1643 |(% style="width:102px" %)16~31|(% style="width:185px" %)HSX663.0~HSX663.15|(% style="width:191px" %)HSX671.0~HSX671.15
1644 |(% style="width:102px" %)32~47|(% style="width:185px" %)HSX664.0~HSX664.15|(% style="width:191px" %)HSX672.0~HSX672.15
1645 |(% style="width:102px" %)48~63|(% style="width:185px" %)HSX665.0~HSX665.15|(% style="width:191px" %)HSX673.0~HSX673.15
1646 |(% style="width:102px" %)64~79|(% style="width:185px" %)HSX666.0~HSX666.15|(% style="width:191px" %)HSX674.0~HSX674.15
1647 |(% style="width:102px" %)80~95|(% style="width:185px" %)HSX667.0~HSX667.15|(% style="width:191px" %)HSX675.0~HSX675.15
1648 |(% style="width:102px" %)96~111|(% style="width:185px" %)HSX668.0~HSX668.15|(% style="width:191px" %)HSX676.0~HSX676.15
1649 |(% style="width:102px" %)112~127|(% style="width:185px" %)HSX669.0~HSX669.15|(% style="width:191px" %)HSX677.0~HSX677.15
1650 |(% style="width:102px" %)128~143|(% style="width:185px" %)HSX1262.0~HSX1262.15|(% style="width:191px" %)HSX1270.0~HSX1270.15
1651 |(% style="width:102px" %)144~159|(% style="width:185px" %)HSX1263.0~HSX1263.15|(% style="width:191px" %)HSX1271.0~HSX1271.15
1652 |(% style="width:102px" %)160~175|(% style="width:185px" %)HSX1264.0~HSX1264.15|(% style="width:191px" %)HSX1272.0~HSX1272.15
1653 |(% style="width:102px" %)176~191|(% style="width:185px" %)HSX1265.0~HSX1265.15|(% style="width:191px" %)HSX1273.0~HSX1273.15
1654 |(% style="width:102px" %)192~207|(% style="width:185px" %)HSX1266.0~HSX1266.15|(% style="width:191px" %)HSX1274.0~HSX1274.15
1655 |(% style="width:102px" %)208~223|(% style="width:185px" %)HSX1267.0~HSX1267.15|(% style="width:191px" %)HSX1275.0~HSX1275.15
1656 |(% style="width:102px" %)224~239|(% style="width:185px" %)HSX1268.0~HSX1268.15|(% style="width:191px" %)HSX1276.0~HSX1276.15
1657 |(% style="width:102px" %)240~255|(% style="width:185px" %)HSX1269.0~HSX1269.15|(% style="width:191px" %)HSX1277.0~HSX1277.15
1658 |(% rowspan="4" style="width:135px" %)9|(% style="width:102px" %)0~~15|(% style="width:185px" %)HSX678.0~~678.15|(% style="width:191px" %)HSX686.0~~686.15
1659 |(% style="width:102px" %)16~~31|(% style="width:185px" %)HSX679.0~~679.15|(% style="width:191px" %)HSX687.0~~687.15
1660 |(% style="width:102px" %)32~~47|(% style="width:185px" %)HSX680.0~~680.15|(% style="width:191px" %)HSX688.0~~688.15
1661 |(% style="width:102px" %)48~~63|(% style="width:185px" %)HSX681.0~~681.15|(% style="width:191px" %)HSX689.0~~689.15
1662 |(% rowspan="4" style="width:135px" %)10|(% style="width:102px" %)0~~15|(% style="width:185px" %)HSX694.0~~694.15|(% style="width:191px" %)HSX702.0~~702.15
1663 |(% style="width:102px" %)16~~31|(% style="width:185px" %)HSX695.0~~695.15|(% style="width:191px" %)HSX703.0~~703.15
1664 |(% style="width:102px" %)32~~47|(% style="width:185px" %)HSX696.0~~696.15|(% style="width:191px" %)HSX704.0~~704.15
1665 |(% style="width:102px" %)48~~63|(% style="width:185px" %)HSX697.0~~697.15|(% style="width:191px" %)HSX705.0~~705.15
1666 |(% rowspan="4" style="width:135px" %)11|(% style="width:102px" %)0~~15|(% style="width:185px" %)HSX710.0~~710.15|(% style="width:191px" %)HSX718.0~~718.15
1667 |(% style="width:102px" %)16~~31|(% style="width:185px" %)HSX711.0~~711.15|(% style="width:191px" %)HSX719.0~~719.15
1668 |(% style="width:102px" %)32~~47|(% style="width:185px" %)HSX712.0~~712.15|(% style="width:191px" %)HSX720.0~~720.15
1669 |(% style="width:102px" %)48~~63|(% style="width:185px" %)HSX713.0~~713.15|(% style="width:191px" %)HSX721.0~~721.15
1670 |(% rowspan="4" style="width:135px" %)12|(% style="width:102px" %)0~~15|(% style="width:185px" %)HSX726.0~~726.15|(% style="width:191px" %)HSX734.0~~734.15
1671 |(% style="width:102px" %)16~~31|(% style="width:185px" %)HSX727.0~~727.15|(% style="width:191px" %)HSX735.0~~735.15
1672 |(% style="width:102px" %)32~~47|(% style="width:185px" %)HSX728.0~~728.15|(% style="width:191px" %)HSX736.0~~736.15
1673 |(% style="width:102px" %)48~~63|(% style="width:185px" %)HSX729.0~~729.15|(% style="width:191px" %)HSX737.0~~737.15
1674 |(% rowspan="4" style="width:135px" %)13|(% style="width:102px" %)0~~15|(% style="width:185px" %)HSX742.0~~742.15|(% style="width:191px" %)HSX750.0~~750.15
1675 |(% style="width:102px" %)16~~31|(% style="width:185px" %)HSX743.0~~743.15|(% style="width:191px" %)HSX751.0~~751.15
1676 |(% style="width:102px" %)32~~47|(% style="width:185px" %)HSX744.0~~744.15|(% style="width:191px" %)HSX752.0~~752.15
1677 |(% style="width:102px" %)48~~63|(% style="width:185px" %)HSX745.0~~745.15|(% style="width:191px" %)HSX753.0~~753.15
1678 |(% rowspan="4" style="width:135px" %)14|(% style="width:102px" %)0~~15|(% style="width:185px" %)HSX758.0~~758.15|(% style="width:191px" %)HSX766.0~~766.15
1679 |(% style="width:102px" %)16~~31|(% style="width:185px" %)HSX759.0~~759.15|(% style="width:191px" %)HSX767.0~~767.15
1680 |(% style="width:102px" %)32~~47|(% style="width:185px" %)HSX760.0~~760.15|(% style="width:191px" %)HSX768.0~~768.15
1681 |(% style="width:102px" %)48~~63|(% style="width:185px" %)HSX761.0~~761.15|(% style="width:191px" %)HSX769.0~~769.15
1682 |(% rowspan="4" style="width:135px" %)15|(% style="width:102px" %)0~~15|(% style="width:185px" %)HSX774.0~~774.15|(% style="width:191px" %)HSX782.0~~782.15
1683 |(% style="width:102px" %)16~~31|(% style="width:185px" %)HSX775.0~~775.15|(% style="width:191px" %)HSX783.0~~783.15
1684 |(% style="width:102px" %)32~~47|(% style="width:185px" %)HSX776.0~~776.15|(% style="width:191px" %)HSX784.0~~784.15
1685 |(% style="width:102px" %)48~~63|(% style="width:185px" %)HSX777.0~~777.15|(% style="width:191px" %)HSX785.0~~785.15
1686 |(% rowspan="4" style="width:135px" %)16|(% style="width:102px" %)0~~15|(% style="width:185px" %)HSX790.0~~790.15|(% style="width:191px" %)HSX798.0~~798.15
1687 |(% style="width:102px" %)16~~31|(% style="width:185px" %)HSX791.0~~791.15|(% style="width:191px" %)HSX799.0~~799.15
1688 |(% style="width:102px" %)32~~47|(% style="width:185px" %)HSX792.0~~792.15|(% style="width:191px" %)HSX800.0~~800.15
1689 |(% style="width:102px" %)48~~63|(% style="width:185px" %)HSX793.0~~793.15|(% style="width:191px" %)HSX801.0~~801.15