Changes for page 15 Fault Troubleshoot

Last modified by Mora Zhou on 2024/12/04 18:12

From version 11.1
edited by Theodore Xu
on 2023/01/07 13:51
Change comment: There is no comment for this version
To version 15.1
edited by Mora Zhou
on 2023/12/22 11:08
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.AiXia
1 +XWiki.Mora
Content
... ... @@ -1,6 +1,6 @@
1 -= **1 Display faulty** =
1 += **Display faulty** =
2 2  
3 -The following is mainly talking about the how to judge and treat the HMI when the users come across the faulty issue.
3 +The following is mainly talking about how to judge and treat HMI when the users come across the faulty issue.
4 4  
5 5  There are mainly three kinds of most common display failures:
6 6  
... ... @@ -126,7 +126,7 @@
126 126  ** If yes, it can enter the backstage interface, please check whether the LCD is in good contact, whether the cable is oxidized, or try to replace the normal LCD;
127 127  ** If not, please replace the motherboard;
128 128  
129 -= **2 USB faulty** =
129 += **USB faulty** =
130 130  
131 131  This document is mainly teaching that how to locate the problem if the HMI cannot be detected when connect to PC by the USB cable. Totally there are 3 aspects need to consider: PC USB port, HMI USB port, USB cable.
132 132  
... ... @@ -151,7 +151,7 @@
151 151  
152 152  Already used for a while, USB is OK and fine before: Maybe it is caused by interference from the site, check all the devices whether are well grounded or not.
153 153  
154 -= **3 Touch faulty** =
154 += **Touch faulty** =
155 155  
156 156  This document is mainly teaching that how to locate the problem if the HMI cannot exit the calibration screen. Totally there are 3 aspects need to consider: calibrate tool, calibration settings, touch board.
157 157  
... ... @@ -168,7 +168,7 @@
168 168  * **Method 1: **Is the HMI already installed on the cabinet? 
169 169  ** please uninstall it from cabinet and try to calibrate it again. if the pressure of the lock on the cabinet too much may cause the HMI to touch abnormally.
170 170  * **Method 2: **Please check whether the protective film of HMI is abnormal or bulging.
171 -** please remove the protective film and try the calibration again. Because the HMI's protective film may also cause touch abnormalities if it is stuck to the touch screen.
171 +** please remove the protective film and try the calibration again. Because HMI's protective film may cause touch abnormalities if it is stuck to the touch board.
172 172  * **Method 3: **Please use the download tool of the software to remove the calibration, please try to use the tip object to calibrate the HMI accurately.
173 173  
174 174  (% style="text-align:center" %)
... ... @@ -178,4 +178,4 @@
178 178  
179 179  * **Method :**Please check whether the TCH light of the HMI is abnormally on or always on without touching the HMI?
180 180  ** please replace the new touch board.
181 -* If all options above are still not help to the calibration, please connect US.
181 +* If all options above are still not help to the calibration, please connect us.