Changes for page 02 Special Function

Last modified by Hunter on 2026/03/10 15:59

From version 19.1
edited by Hunter
on 2026/03/10 15:20
Change comment: There is no comment for this version
To version 11.1
edited by Hunter
on 2026/03/10 13:52
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -41,14 +41,10 @@
41 41  
42 42  HMI supports USB printer and serial printer. Detail type of printer, please refer to download link.
43 43  
44 -[[Download link>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Special%20Function/New%20Demo/Printer%20DemoV2%28Epson%26Argox%26Save%20Screenshot%29.zip]]
44 +[[Download link>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/printer%20demo%20v1.1.zip]]
45 45  
46 46  = **4 Remote Control** =
47 47  
48 -{{error}}
49 -✎Note: The following solution is not recommended, as the related models(PI8000, PI9000, PI3000-O) have been discontinued for a long time. Please use the [[V-NET 2.0>>doc:V-Net 2\.0.WebHome]] Cloud platform and ig series HMI as the recommended remote access solution.
50 -{{/error}}
51 -
52 52  Here provides three solutions to remote control HMI.
53 53  
54 54  Solution1: HMI must be PI8000 or PI9000 with -R. Remote control with WECON cloud server.
... ... @@ -57,13 +57,13 @@
57 57  
58 58  Solution3: HMI must be PI3000 with -O model. Remote control by HMI System Monitor.
59 59  
56 +[[Download link>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Special%20Function/Remote%20control-P%2BD%2BV-20241023T055612Z-001.zip]]
57 +
60 60  = **5 Short Message** =
61 61  
62 -{{error}}
63 -✎Note: The SMS library is currently not supported on any currently available models. Please use the [[Lua SMS demo>>doc:PIStudio.2 Demo.Lua Script.WebHome||anchor="H23LuaSMS"]] as the solution. For function capabilities, please refer to the [[Function Limits table>>doc:PIStudio.16 Appendix.WebHome||anchor="HPIStudioFunctionLimits"]]
64 -{{/error}}
60 +This is the extend function in WECON HMI. Extended a SMS module that must support AT command to communicate with HMI. Alarm information could be sent to users by short message, and users could control HMI by sending short message.
65 65  
66 -Extended a SMS module that must support AT command to communicate with HMI. Alarm information could be sent to users by short message, and users could control HMI by sending short message.
62 +[[Download link>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Special%20Function/SMS-20241023T055847Z-001.zip]]
67 67  
68 68  = **6 Multi-Link(V1.0)** =
69 69