Changes for page 04 Library
Last modified by Joe on 2026/09/07 11:02
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -384,6 +384,12 @@ 384 384 (% style="text-align:center" %) 385 385 [[image:地址库 2.png||data-xwiki-image-style-alignment="center" height="429" width="659" class="img-thumbnail"]] 386 386 387 +(% class="box infomessage" %) 388 +((( 389 +Note: If Names starting with the letter "B" for address library entries, there will be an error when the HMI project is compiled. 390 +Names starting with the letter "B" cannot be used for address name. Please change the name to start with a different character. 391 +))) 392 + 387 387 (% class="table-bordered" %) 388 388 |=(% style="width: 155px;" %)**Item**|=(% style="width: 689px;" %)**Description** 389 389 |(% style="width:155px" %)Word Address|(% style="width:689px" %)Select [Word Address] to display word addresses in list ... ... @@ -425,6 +425,12 @@ 425 425 426 426 For example: Forward "D0" to "HDW100" (length: 10), so the address D0, D1,..., D9 would be related to HDW100, HDW101, .., HDW109. 427 427 434 +(% class="box infomessage" %) 435 +((( 436 +Note: How can I access the HMI Pi3102iG clock via Modbus? 437 +The mapping function can map external PLC addresses to internal HMI addresses, enabling the modification of values in the HMI's internal registers. For example, when you connect a device to HMI with Modbus protocol and you want to use Modbus address to modify the HMI time, you can use mapping function to map Modbus address to HMI clock internal register. 438 +))) 439 + 428 428 **Description** 429 429 430 430 (% style="text-align:center" %) ... ... @@ -485,7 +485,7 @@ 485 485 486 486 **Global mapping control** 487 487 488 -The function and mode are similar to [Mapping], but it is used to control all mapping items. The setting screen below show; 500 +The function and mode are similar to [Mapping], but it is used to control all mapping items. Global mapping can only be enabled when the global control address is set to 0. The entire instruction set will not be enabled when the address is set to 1. If "Control Enabled when ON" is checked, the opposite will happen. When the address is set to 1, mapping is enabled, and when it is set to 0, mapping is disabled. The setting screen below show; 489 489 490 490 (% style="text-align:center" %) 491 491 [[image:7.Library_html_a04eddcc1d2f2f14.png||data-xwiki-image-style-alignment="center" height="199" width="419" class="img-thumbnail"]] ... ... @@ -545,8 +545,14 @@ 545 545 546 546 = String table = 547 547 548 -A collection entered by the user in advance, contents of table can be referenced by text object. The string table support eightlanguages at max.560 +A collection entered by the user in advance, contents of table can be referenced by text object. The string table support //8// languages at max. 549 549 562 +(% class="box infomessage" %) 563 +((( 564 +Note:In PI10.0 or above version, String table can support **48** languages at max. Please refer to the following setting: 565 +Project Setting ➡ Exend➡Enable "Multi-language extension" 566 +))) 567 + 550 550 Click on the String table in "Library" on the upper left corner of the software, as shown in the following figure: 551 551 552 552 (% style="text-align:center" %)