Changes for page 04 Library

Last modified by Joe on 2026/09/07 11:02

From version 11.1
edited by xingzhi lin
on 2025/09/24 10:01
Change comment: There is no comment for this version
To version 18.1
edited by Joe
on 2026/09/07 11:02
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.lxz
1 +XWiki.joe
Content
... ... @@ -384,6 +384,12 @@
384 384  (% style="text-align:center" %)
385 385  [[image:地址库 2.png||data-xwiki-image-style-alignment="center" height="429" width="659" class="img-thumbnail"]]
386 386  
387 +(% class="box infomessage" %)
388 +(((
389 +Note: If Names starting with the letter "B"  for address library entries, there will be an error when the HMI project is compiled.
390 +Names starting with the letter "B" cannot be used for address name. Please change the name to start with a different character.
391 +)))
392 +
387 387  (% class="table-bordered" %)
388 388  |=(% style="width: 155px;" %)**Item**|=(% style="width: 689px;" %)**Description**
389 389  |(% style="width:155px" %)Word Address|(% style="width:689px" %)Select [Word Address] to display word addresses in list
... ... @@ -425,6 +425,12 @@
425 425  
426 426  For example: Forward "D0" to "HDW100" (length: 10), so the address D0, D1,..., D9 would be related to HDW100, HDW101, .., HDW109.
427 427  
434 +(% class="box infomessage" %)
435 +(((
436 +Note: How can I access the HMI Pi3102iG clock via Modbus?
437 +The mapping function can map external PLC addresses to internal HMI addresses, enabling the modification of values ​​in the HMI's internal registers. For example, when you connect a device to HMI with Modbus protocol and you want to use Modbus address to modify the HMI time, you can use mapping function to map Modbus address to HMI clock internal register.
438 +)))
439 +
428 428  **Description**
429 429  
430 430  (% style="text-align:center" %)
... ... @@ -545,8 +545,14 @@
545 545  
546 546  = String table =
547 547  
548 -A collection entered by the user in advance, contents of table can be referenced by text object. The string table support eight languages at max.
560 +A collection entered by the user in advance, contents of table can be referenced by text object. The string table support //8// languages at max.
549 549  
562 +(% class="box infomessage" %)
563 +(((
564 +Note:In PI10.0 or above version, String table can support  **48** languages at max. Please refer to the following setting:
565 +Project Setting ➡ Exend➡Enable "Multi-language extension"
566 +)))
567 +
550 550  Click on the String table in "Library" on the upper left corner of the software, as shown in the following figure:
551 551  
552 552  (% style="text-align:center" %)