Changes for page 04 Library
Last modified by Joe on 2026/09/07 11:02
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -425,12 +425,6 @@ 425 425 426 426 For example: Forward "D0" to "HDW100" (length: 10), so the address D0, D1,..., D9 would be related to HDW100, HDW101, .., HDW109. 427 427 428 -(% class="box infomessage" %) 429 -((( 430 -Note: How can I access the HMI Pi3102iG clock via Modbus? 431 -The mapping function can map external PLC addresses to internal HMI addresses, enabling the modification of values in the HMI's internal registers. For example, when you connect a device to HMI with Modbus protocol and you want to use Modbus address to modify the HMI time, you can use mapping function to map Modbus address to HMI clock internal register. 432 -))) 433 - 434 434 **Description** 435 435 436 436 (% style="text-align:center" %) ... ... @@ -491,7 +491,7 @@ 491 491 492 492 **Global mapping control** 493 493 494 -The function and mode are similar to [Mapping], but it is used to control all mapping items. Global mapping can only be enabled when the global control address is set to 0.Theentire instruction setwill notbe enabled when the addressis set to 1. If "Control Enabled when ON" is checked, the opposite will happen. When the address is set to 1, mappingisenabled, and when it is set to 0, mapping is disabled. The setting screen below show;488 +The function and mode are similar to [Mapping], but it is used to control all mapping items. The setting screen below show; 495 495 496 496 (% style="text-align:center" %) 497 497 [[image:7.Library_html_a04eddcc1d2f2f14.png||data-xwiki-image-style-alignment="center" height="199" width="419" class="img-thumbnail"]] ... ... @@ -750,7 +750,7 @@ 750 750 (% style="text-align:center" %) 751 751 [[image:8.png]] 752 752 753 -== ** Advance** ==747 +== **Advance** == 754 754 755 755 (% style="text-align:center" %) 756 756 [[image:10.png]] ... ... @@ -760,5 +760,5 @@ 760 760 1. **Repeat time: **Specifies the number of times the executor executes after the trigger is triggered. The default value is one. 761 761 1. **Repeat Interval: **Specifies the interval between repetitions. The default value is one second. 762 762 763 -* Control address: This bit address controls whether the** entire scheduled task is started**.757 +* Control address: This bit address controls whether the** entire scheduled task is started**. 764 764 * TTS voice broadcast: Specifies whether to play a voice prompt when the executor executes.