Changes for page 04 Library

Last modified by Joe on 2026/09/07 11:02

From version 15.1
edited by Joe
on 2026/09/01 14:25
Change comment: There is no comment for this version
To version 9.1
edited by Joe
on 2025/09/18 15:00
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -425,12 +425,6 @@
425 425  
426 426  For example: Forward "D0" to "HDW100" (length: 10), so the address D0, D1,..., D9 would be related to HDW100, HDW101, .., HDW109.
427 427  
428 -(% class="box infomessage" %)
429 -(((
430 -Note: How can I access the HMI Pi3102iG clock via Modbus?
431 -The mapping function can map external PLC addresses to internal HMI addresses, enabling the modification of values ​​in the HMI's internal registers. For example, when you connect a device to HMI with Modbus protocol and you want to use Modbus address to modify the HMI time, you can use mapping function to map Modbus address to HMI clock internal register.
432 -)))
433 -
434 434  **Description**
435 435  
436 436  (% style="text-align:center" %)
... ... @@ -491,7 +491,7 @@
491 491  
492 492  **Global mapping control**
493 493  
494 -The function and mode are similar to [Mapping], but it is used to control all mapping items. Global mapping can only be enabled when the global control address is set to 0. The entire instruction set will not be enabled when the address is set to 1. If "Control Enabled when ON" is checked, the opposite will happen. When the address is set to 1, mapping is enabled, and when it is set to 0, mapping is disabled. The setting screen below show;
488 +The function and mode are similar to [Mapping], but it is used to control all mapping items. The setting screen below show;
495 495  
496 496  (% style="text-align:center" %)
497 497  [[image:7.Library_html_a04eddcc1d2f2f14.png||data-xwiki-image-style-alignment="center" height="199" width="419" class="img-thumbnail"]]
... ... @@ -750,7 +750,7 @@
750 750  (% style="text-align:center" %)
751 751  [[image:8.png]]
752 752  
753 -== ** Advance** ==
747 +== **Advance** ==
754 754  
755 755  (% style="text-align:center" %)
756 756  [[image:10.png]]
... ... @@ -760,5 +760,5 @@
760 760  1. **Repeat time: **Specifies the number of times the executor executes after the trigger is triggered. The default value is one.
761 761  1. **Repeat Interval: **Specifies the interval between repetitions. The default value is one second.
762 762  
763 -* Control address: This bit address controls whether the** entire scheduled task is started**.
757 +* Control address: This bit address controls whether the** entire scheduled task is started**.
764 764  * TTS voice broadcast: Specifies whether to play a voice prompt when the executor executes.