Changes for page 04 Library
Last modified by xingzhi lin on 2025/09/24 10:01
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (2 modified, 9 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -543,7 +543,7 @@ 543 543 ** Normal read speed is 0, read-through value is 1, and fast read value is 2. There is no need to fill in the data type in address mapping. The selection of "32-bit register" is special for some PLC whose address interval is 1 in 32 bits. You don't have to choose it. 544 544 ))) 545 545 546 -= String table [[image:1.png]]=546 += String table = 547 547 548 548 A collection entered by the user in advance, contents of table can be referenced by text object. The string table support eight languages at max. 549 549 ... ... @@ -610,4 +610,82 @@ 610 610 (% style="text-align:center" %) 611 611 [[image:2.png]] 612 612 613 -== **TTS function** == 613 +== [[**TTS function**>>https://docs.we-con.com.cn/bin/view/PIStudio/09%20Lua%20Editor/Lua%20Script/#HTTS]] == 614 + 615 += **Schedule** = 616 + 617 +**The schedule function allows the HMI to execute pre-scheduled tasks at specified times or according to specified conditions. 618 +Compatible models: ig series, RH series 619 +The scheduling function supports setting up to 128 scheduled tasks, each with 8 triggers and 8 execution tasks.** 620 + 621 +Project configuration → Library→ Schedule. 622 + 623 +Click "New schedule" to create task. 624 + 625 +(% style="text-align:center" %) 626 +[[image:1.png]] 627 + 628 +== **Trigger** == 629 + 630 + 631 +(% style="text-align:center" %) 632 +[[image:2.png]] 633 + 634 + 635 +(% style="text-align:center" %) 636 +[[image:3.png]] 637 + 638 +There are six different Start task 639 + 640 +**AS Scheduled:** Schedules are divided into four different modes: **Once, Every day, Every week and Every month**. 641 + 642 +* **Once**: This mode executes only once, triggered only when the start time arrives. 643 +* **Every day: **The trigger will be triggered at the same time every day after the start time, and **the trigger interval can be set.** 644 +* **Every week:** It will be triggered on the set date every week after the start time, and the number of weeks for the interval trigger can be set. 645 + 646 +(% style="text-align:center" %) 647 +[[image:4.png]] 648 + 649 +* **Every month: In the monthly mode, there are two modes:** 650 + 651 +1. **By day mode: **In this mode, after the start time, the day of the month can be set to trigger, and you can select multiple months and days. 652 + 653 +(% style="text-align:center" %) 654 +[[image:5.png]] 655 + 656 +1. **Weekly mode:** In this mode, after the start time, the day of the week can be set in the month to trigger. Both the number of weeks and the day of the week can be multiple selected. 657 + 658 +(% style="text-align:center" %) 659 +[[image:6.png]] 660 + 661 +**Bit address value changes: **Set the bit address value to trigger from ON->OFF or from OFF->ON 662 + 663 +(% style="text-align:center" %) 664 +[[image:7.png]] 665 + 666 +**Word address value changes: **Set the word address value to meet the set conditions (greater than, equal to, or less than a certain value) to trigger 667 + 668 +(% style="text-align:center" %) 669 +[[image:8.png]] 670 + 671 +**On the specified screen: **Jump to the specified screen trigger. 672 + 673 +(% style="text-align:center" %) 674 +[[image:9.png]] 675 + 676 +**Successful upload to Cloud: **Triggered when the device successfully or fails to access the cloud. If set to "fail to access the cloud", if the device has not accessed the cloud after a period of time (about 2 minutes) after startup, it will be judged as a cloud access failure. 677 + 678 +(% style="text-align:center" %) 679 +[[image:10.png]] 680 + 681 +**When the specified user logs in: **Set to be triggered after a user successfully logs in. 682 + 683 +(% style="text-align:center" %) 684 +[[image:11.png]] 685 + 686 +(% class="box infomessage" %) 687 +((( 688 +Note: 689 +~1. After setting a start time, the trigger will automatically start at the specified start time. 690 +2. All triggers must have a start time, and an end time is optional. If an end time is set, the trigger will not fire if the current time exceeds the end time. If an end time is not set, the trigger will persist if the current time exceeds the start time. 691 +)))
- 1.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 - 25.3 KB1 +13.3 KB - Content
- 2.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 - 40.1 KB1 +17.5 KB - Content
- 10.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.9 KB - Content
- 11.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.6 KB - Content
- 3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.3 KB - Content
- 4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +7.9 KB - Content
- 5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.0 KB - Content
- 6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.3 KB - Content
- 7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.2 KB - Content
- 8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.4 KB - Content
- 9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.9 KB - Content