... ... @@ -1,1 +1,1 @@ 1 -XWiki. DevinChen1 +XWiki.joe - Content
-
... ... @@ -1,8 +1,24 @@ 1 1 = TwinCAT_PLC_Ethernet = 2 2 3 -Supported series: Twincat 3 +Supported series: Twincat 4 4 5 +**HMI Settings** 6 + 7 +|**Item**|**Settings**|**Note** 8 +|Protocol|TwinCAT_PLC_Ethernet| 9 +|Connection|Ethernet| 10 +|Port NO.|48898| 11 +|ADS port|801/811/821/831| 12 +|PLC station No.|1 13 + 14 + Choose protocol: TwinCAT_PLC_Ethernet 15 + 5 5 (% style="text-align:center" %) 17 +[[image:0rPAMOoxzH.png]] 18 + 19 +Setting→PLC IP Address→AMS NetId 20 + 21 +(% style="text-align:center" %) 6 6 [[image:RVUyBW3DPV.png]] 7 7 8 8 **PLC Settings** ... ... @@ -12,7 +12,7 @@ 12 12 (% style="text-align:center" %) 13 13 [[image:lTAhpgCBWJ.png]] 14 14 15 -Route Settings→Add Route Dialog→ Broadcast Search→ choose PLC→ modify Route Name asHMI name →modifyAmsNetId as HMI AmsNetId: 192.168.50.154.1.1 **(HMI IP + .1.1) **→ select the option of IP Address→ set HMI IP in Address info→ Add Route31 +Route Settings→Add Route Dialog→ Broadcast Search→ choose PLC→ modify HMI name → change AmsNetId as HMI AmsNetId: 192.168.50.154.1.1 **(HMI IP + .1.1) **→ select the option of IP Address→ set HMI IP in Address info→ Add Route 16 16 17 17 (% style="text-align:center" %) 18 18 [[image:gfF9dtMLW7.png]] ... ... @@ -22,26 +22,8 @@ 22 22 (% style="text-align:center" %) 23 23 [[image:0bvTefCtCv.png]] 24 24 25 -(% id="cke_bm_680S" style="display:none" %)** **(%%)**HMI Settings** 26 - 27 -|**Item**|**Settings**|**Note** 28 -|Protocol|TwinCAT_PLC_Ethernet| 29 -|Connection|Ethernet| 30 -|Port NO.|48898| 31 -|ADS port|801/811/821/831| 32 -|PLC station No.|1 33 - 34 - Choose protocol: TwinCAT_PLC_Ethernet 35 - 36 -(% style="text-align:center" %) 37 -[[image:0rPAMOoxzH.png]] 38 - 39 -Setting→PLC IP Address→AMS NetId (Fill in according to the actual AMS NetId search by PLC) 40 - 41 41 **How to import the tags** 42 42 43 -**TwinCat 2:** 44 - 45 45 Open TwinCAT PLC Control→ edit program→ save the program in a file → Project → Rebuild all 46 46 47 47 (% style="text-align:center" %) ... ... @@ -55,25 +55,6 @@ 55 55 Note: After "Rebuild all", there will be a file whose format is "tpy". 56 56 ))) 57 57 58 -**TwinCat 3:** 59 - 60 -~1. In the TwinCat 3, the settings tab of PLC project, select the TPY File option. 61 - 62 -(% style="text-align:center" %) 63 -[[image:PvVEXT2lyv.png]] 64 - 65 -2. Activation configuration 66 - 67 -(% style="text-align:center" %) 68 -[[image:OxqjpdmNDx.png]] 69 - 70 -3.Open the project folder to find the *.tpy file 71 - 72 -(% style="text-align:center" %) 73 -[[image:h5DzS2ZRIk.png]] 74 - 75 -PIStudio Settings 76 - 77 77 Labels mange→ Import Tag From File→ choose the file whose format is "tpy" in the file →Save 78 78 79 79 (% style="text-align:center" %)
- OxqjpdmNDx.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.DevinChen - Size
-
... ... @@ -1,1 +1,0 @@ 1 -92.6 KB - Content
- PvVEXT2lyv.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.DevinChen - Size
-
... ... @@ -1,1 +1,0 @@ 1 -92.9 KB - Content
- h5DzS2ZRIk.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.DevinChen - Size
-
... ... @@ -1,1 +1,0 @@ 1 -64.1 KB - Content