Changes for page BECKHOFF

Last modified by Devin Chen on 2025/04/07 17:26

From version 3.4
edited by Joe
on 2024/08/26 17:55
Change comment: There is no comment for this version
To version 7.1
edited by Devin Chen
on 2025/02/14 15:07
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.joe
1 +XWiki.DevinChen
Content
... ... @@ -2,23 +2,7 @@
2 2  
3 3  Supported series: Twincat
4 4  
5 -**HMI Settings**
6 -
7 -|**Item**|**Settings**|**Note**
8 -|Protocol|TwinCAT_PLC_Ethernet|
9 -|Connection|Ethernet|
10 -|Port NO.|48898|
11 -|ADS port|801/811/821/831|
12 -|PLC station No.|1
13 -
14 - Choose protocol: TwinCAT_PLC_Ethernet
15 -
16 16  (% style="text-align:center" %)
17 -[[image:0rPAMOoxzH.png]]
18 -
19 -setting→PLC IP Address→AMS NetId
20 -
21 -(% style="text-align:center" %)
22 22  [[image:RVUyBW3DPV.png]]
23 23  
24 24  **PLC Settings**
... ... @@ -28,16 +28,37 @@
28 28  (% style="text-align:center" %)
29 29  [[image:lTAhpgCBWJ.png]]
30 30  
31 -Route Settings**→Add Route Dialog→** Broadcast Search→ choose PLC→ modify HMI name → change AmsNetId as 192.168.50.154.1.1 **(HMI IP + .1.1) **→  select the option of IP Address→ set HMI IP in Address info→ Add route
15 +Route Settings→Add Route Dialog→ Broadcast Search→ choose PLC→ modify Route Name as HMI name → modify AmsNetId as HMI AmsNetId: 192.168.50.154.1.1 **(HMI IP + .1.1) **→  select the option of IP Address→ set HMI IP in Address info→ Add Route
32 32  
33 33  (% style="text-align:center" %)
34 34  [[image:gfF9dtMLW7.png]]
35 35  
36 -**how to import the tags**
20 +Actions→ Activate configuration
37 37  
38 -Open TwinCAT PLC Control→ edit program→ save the program in a path → Project → Rebuild all
22 +(% style="text-align:center" %)
23 +[[image:0bvTefCtCv.png]]
39 39  
25 +(% id="cke_bm_680S" style="display:none" %)** **(%%)**HMI Settings**
26 +
27 +|**Item**|**Settings**|**Note**
28 +|Protocol|TwinCAT_PLC_Ethernet|
29 +|Connection|Ethernet|
30 +|Port NO.|48898|
31 +|ADS port|801/811/821/831|
32 +|PLC station No.|1
33 +
34 + Choose protocol: TwinCAT_PLC_Ethernet
35 +
40 40  (% style="text-align:center" %)
37 +[[image:0rPAMOoxzH.png]]
38 +
39 +Setting→PLC IP Address→AMS NetId (Fill in according to the actual AMS NetId search by PLC)
40 +
41 +**How to import the tags**
42 +
43 +Open TwinCAT PLC Control→ edit program→ save the program in a file → Project → Rebuild all
44 +
45 +(% style="text-align:center" %)
41 41  [[image:f925vKrK47.png]]
42 42  
43 43  (% style="text-align:center" %)
... ... @@ -48,9 +48,25 @@
48 48  Note: After "Rebuild all", there will be a file whose format is "tpy".
49 49  )))
50 50  
51 -Labels mange→ Import Tag From File→ choose the file whose format is "tpy" in the path →Save
56 +Labels mange→ Import Tag From File→ choose the file whose format is "tpy" in the file →Save
52 52  
53 53  (% style="text-align:center" %)
54 54  [[image:qaOxmsAR2S.png]]
55 55  
56 -
61 +
62 +**Support Variable Type**
63 +
64 +|=Data Type|=PIStudio Data Format|=Range
65 +|=BOOL|Bit|0~~1
66 +|=BYTE|16-bit Unsigned/Binary/BCD/Hex|0~~255
67 +|=WORD|16-bit Unsigned/Binary/BCD/Hex|0~~65535
68 +|=DWORD|32-bit Unsigned/Binary/BCD/Hex |0~~4294967295
69 +|=SINT|16-bit Signed/Binary/BCD/Hex|-128~~127
70 +|=USINT|16-bit Unsigned/Binary/BCD/Hex|0~~255
71 +|=INT|16-bit Signed/Binary/BCD/Hex|-32768~~32767
72 +|=UINT|16-bit Unsigned/Binary/BCD/Hex|0~~65535
73 +|=DINT|32-bit Signed/Binary/BCD/Hex|-2147483648~~2147483647
74 +|=UDINT|32-bit Unsigned/Binary/BCD/Hex|0~~4294967295
75 +|=REAL|32-bit Floating|1.00E-44~~3.40E+38
76 +|=LREAL|64-bit Floating|4.94065645841247e-324~~1.7976931348623157e+308
77 +|=STRING|STRING|
0bvTefCtCv.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +54.7 KB
Content