Changes for page BECKHOFF
Last modified by Devin Chen on 2025/04/07 17:26
From version 3.4
edited by Joe
on 2024/08/26 17:55
on 2024/08/26 17:55
Change comment:
There is no comment for this version
To version 9.1
edited by Devin Chen
on 2025/03/22 11:40
on 2025/03/22 11:40
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. joe1 +XWiki.DevinChen - Content
-
... ... @@ -1,24 +1,8 @@ 1 1 = TwinCAT_PLC_Ethernet = 2 2 3 -Supported series: Twincat 3 +Supported series: Twincat 4 4 5 -**HMI Settings** 6 - 7 -|**Item**|**Settings**|**Note** 8 -|Protocol|TwinCAT_PLC_Ethernet| 9 -|Connection|Ethernet| 10 -|Port NO.|48898| 11 -|ADS port|801/811/821/831| 12 -|PLC station No.|1 13 - 14 - Choose protocol: TwinCAT_PLC_Ethernet 15 - 16 16 (% style="text-align:center" %) 17 -[[image:0rPAMOoxzH.png]] 18 - 19 -setting→PLC IP Address→AMS NetId 20 - 21 -(% style="text-align:center" %) 22 22 [[image:RVUyBW3DPV.png]] 23 23 24 24 **PLC Settings** ... ... @@ -28,16 +28,37 @@ 28 28 (% style="text-align:center" %) 29 29 [[image:lTAhpgCBWJ.png]] 30 30 31 -Route Settings **→Add Route Dialog→**Broadcast Search→ choose PLC→ modify HMI name →changeAmsNetId as 192.168.50.154.1.1 **(HMI IP + .1.1) **→ select the option of IP Address→ set HMI IP in Address info→ Addroute15 +Route Settings→Add Route Dialog→ Broadcast Search→ choose PLC→ modify Route Name as HMI name → modify AmsNetId as HMI AmsNetId: 192.168.50.154.1.1 **(HMI IP + .1.1) **→ select the option of IP Address→ set HMI IP in Address info→ Add Route 32 32 33 33 (% style="text-align:center" %) 34 34 [[image:gfF9dtMLW7.png]] 35 35 36 - **howtoimportthetags**20 +Actions→ Activate configuration 37 37 38 -Open TwinCAT PLC Control→ edit program→ save the program in a path → Project → Rebuild all 22 +(% style="text-align:center" %) 23 +[[image:0bvTefCtCv.png]] 39 39 25 +(% id="cke_bm_680S" style="display:none" %)** **(%%)**HMI Settings** 26 + 27 +|**Item**|**Settings**|**Note** 28 +|Protocol|TwinCAT_PLC_Ethernet| 29 +|Connection|Ethernet| 30 +|Port NO.|48898| 31 +|ADS port|801/811/821/831| 32 +|PLC station No.|1 33 + 34 + Choose protocol: TwinCAT_PLC_Ethernet 35 + 40 40 (% style="text-align:center" %) 37 +[[image:0rPAMOoxzH.png]] 38 + 39 +Setting→PLC IP Address→AMS NetId (Fill in according to the actual AMS NetId search by PLC) 40 + 41 +**How to import the tags** 42 + 43 +Open TwinCAT PLC Control→ edit program→ save the program in a file → Project → Rebuild all 44 + 45 +(% style="text-align:center" %) 41 41 [[image:f925vKrK47.png]] 42 42 43 43 (% style="text-align:center" %) ... ... @@ -48,9 +48,25 @@ 48 48 Note: After "Rebuild all", there will be a file whose format is "tpy". 49 49 ))) 50 50 51 -Labels mange→ Import Tag From File→ choose the file whose format is "tpy" in the path→Save56 +Labels mange→ Import Tag From File→ choose the file whose format is "tpy" in the file →Save 52 52 53 53 (% style="text-align:center" %) 54 54 [[image:qaOxmsAR2S.png]] 55 55 56 - 61 + 62 +**Support Variable Type** 63 + 64 +|=Data Type|=PIStudio Data Format|=Range 65 +|=BOOL|Bit|0~~1 66 +|=BYTE|16-bit Unsigned/Binary/BCD/Hex|0~~255 67 +|=WORD|16-bit Unsigned/Binary/BCD/Hex|0~~65535 68 +|=DWORD|32-bit Unsigned/Binary/BCD/Hex |0~~4294967295 69 +|=SINT|16-bit Signed/Binary/BCD/Hex|-128~~127 70 +|=USINT|16-bit Unsigned/Binary/BCD/Hex|0~~255 71 +|=INT|16-bit Signed/Binary/BCD/Hex|-32768~~32767 72 +|=UINT|16-bit Unsigned/Binary/BCD/Hex|0~~65535 73 +|=DINT|32-bit Signed/Binary/BCD/Hex|-2147483648~~2147483647 74 +|=UDINT|32-bit Unsigned/Binary/BCD/Hex|0~~4294967295 75 +|=REAL|32-bit Floating|1.00E-44~~3.40E+38 76 +|=LREAL|64-bit Floating|4.94065645841247e-324~~1.7976931348623157e+308 77 +|=STRING|STRING|
- 0bvTefCtCv.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +54.7 KB - Content