Changes for page BECKHOFF

Last modified by Devin Chen on 2025/04/07 17:26

From version 5.1
edited by Joe
on 2024/08/26 18:20
Change comment: There is no comment for this version
To version 10.1
edited by Devin Chen
on 2025/04/07 17:26
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.joe
1 +XWiki.DevinChen
Content
... ... @@ -1,24 +1,8 @@
1 1  = TwinCAT_PLC_Ethernet =
2 2  
3 -Supported series: Twincat
3 +Supported series: Twincat
4 4  
5 -**HMI Settings**
6 -
7 -|**Item**|**Settings**|**Note**
8 -|Protocol|TwinCAT_PLC_Ethernet|
9 -|Connection|Ethernet|
10 -|Port NO.|48898|
11 -|ADS port|801/811/821/831|
12 -|PLC station No.|1
13 -
14 - Choose protocol: TwinCAT_PLC_Ethernet
15 -
16 16  (% style="text-align:center" %)
17 -[[image:0rPAMOoxzH.png]]
18 -
19 -Setting→PLC IP Address→AMS NetId
20 -
21 -(% style="text-align:center" %)
22 22  [[image:RVUyBW3DPV.png]]
23 23  
24 24  **PLC Settings**
... ... @@ -28,7 +28,7 @@
28 28  (% style="text-align:center" %)
29 29  [[image:lTAhpgCBWJ.png]]
30 30  
31 -Route Settings→Add Route Dialog→ Broadcast Search→ choose PLC→ modify HMI name → change AmsNetId as HMI AmsNetId: 192.168.50.154.1.1 **(HMI IP + .1.1) **→  select the option of IP Address→ set HMI IP in Address info→ Add Route
15 +Route Settings→Add Route Dialog→ Broadcast Search→ choose PLC→ modify Route Name as HMI name → modify AmsNetId as HMI AmsNetId: 192.168.50.154.1.1 **(HMI IP + .1.1) **→  select the option of IP Address→ set HMI IP in Address info→ Add Route
32 32  
33 33  (% style="text-align:center" %)
34 34  [[image:gfF9dtMLW7.png]]
... ... @@ -38,8 +38,26 @@
38 38  (% style="text-align:center" %)
39 39  [[image:0bvTefCtCv.png]]
40 40  
25 +(% id="cke_bm_680S" style="display:none" %)** **(%%)**HMI Settings**
26 +
27 +|**Item**|**Settings**|**Note**
28 +|Protocol|TwinCAT_PLC_Ethernet|
29 +|Connection|Ethernet|
30 +|Port NO.|48898|
31 +|ADS port|801/811/821/831|
32 +|PLC station No.|1
33 +
34 + Choose protocol: TwinCAT_PLC_Ethernet
35 +
36 +(% style="text-align:center" %)
37 +[[image:0rPAMOoxzH.png]]
38 +
39 +Setting→PLC IP Address→AMS NetId (Fill in according to the actual AMS NetId search by PLC)
40 +
41 41  **How to import the tags**
42 42  
43 +**TwinCat 2:**
44 +
43 43  Open TwinCAT PLC Control→ edit program→ save the program in a file → Project → Rebuild all
44 44  
45 45  (% style="text-align:center" %)
... ... @@ -53,6 +53,25 @@
53 53  Note: After "Rebuild all", there will be a file whose format is "tpy".
54 54  )))
55 55  
58 +**TwinCat 3:**
59 +
60 +~1. In the TwinCat 3, the settings tab of PLC project, select the TPY File option.
61 +
62 +(% style="text-align:center" %)
63 +[[image:PvVEXT2lyv.png]]
64 +
65 +2. Activation configuration
66 +
67 +(% style="text-align:center" %)
68 +[[image:OxqjpdmNDx.png]]
69 +
70 +3.Open the project folder to find the *.tpy file
71 +
72 +(% style="text-align:center" %)
73 +[[image:h5DzS2ZRIk.png]]
74 +
75 +PIStudio Settings
76 +
56 56  Labels mange→ Import Tag From File→ choose the file whose format is "tpy" in the file →Save
57 57  
58 58  (% style="text-align:center" %)
OxqjpdmNDx.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.DevinChen
Size
... ... @@ -1,0 +1,1 @@
1 +92.6 KB
Content
PvVEXT2lyv.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.DevinChen
Size
... ... @@ -1,0 +1,1 @@
1 +92.9 KB
Content
h5DzS2ZRIk.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.DevinChen
Size
... ... @@ -1,0 +1,1 @@
1 +64.1 KB
Content