Changes for page BECKHOFF
Last modified by Devin Chen on 2025/04/07 17:26
From version 6.1
edited by Joe
on 2024/08/26 18:22
on 2024/08/26 18:22
Change comment:
There is no comment for this version
To version 10.1
edited by Devin Chen
on 2025/04/07 17:26
on 2025/04/07 17:26
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. joe1 +XWiki.DevinChen - Content
-
... ... @@ -1,24 +1,8 @@ 1 1 = TwinCAT_PLC_Ethernet = 2 2 3 -Supported series: Twincat 3 +Supported series: Twincat 4 4 5 -**HMI Settings** 6 - 7 -|**Item**|**Settings**|**Note** 8 -|Protocol|TwinCAT_PLC_Ethernet| 9 -|Connection|Ethernet| 10 -|Port NO.|48898| 11 -|ADS port|801/811/821/831| 12 -|PLC station No.|1 13 - 14 - Choose protocol: TwinCAT_PLC_Ethernet 15 - 16 16 (% style="text-align:center" %) 17 -[[image:0rPAMOoxzH.png]] 18 - 19 -Setting→PLC IP Address→AMS NetId 20 - 21 -(% style="text-align:center" %) 22 22 [[image:RVUyBW3DPV.png]] 23 23 24 24 **PLC Settings** ... ... @@ -38,8 +38,26 @@ 38 38 (% style="text-align:center" %) 39 39 [[image:0bvTefCtCv.png]] 40 40 25 +(% id="cke_bm_680S" style="display:none" %)** **(%%)**HMI Settings** 26 + 27 +|**Item**|**Settings**|**Note** 28 +|Protocol|TwinCAT_PLC_Ethernet| 29 +|Connection|Ethernet| 30 +|Port NO.|48898| 31 +|ADS port|801/811/821/831| 32 +|PLC station No.|1 33 + 34 + Choose protocol: TwinCAT_PLC_Ethernet 35 + 36 +(% style="text-align:center" %) 37 +[[image:0rPAMOoxzH.png]] 38 + 39 +Setting→PLC IP Address→AMS NetId (Fill in according to the actual AMS NetId search by PLC) 40 + 41 41 **How to import the tags** 42 42 43 +**TwinCat 2:** 44 + 43 43 Open TwinCAT PLC Control→ edit program→ save the program in a file → Project → Rebuild all 44 44 45 45 (% style="text-align:center" %) ... ... @@ -53,6 +53,25 @@ 53 53 Note: After "Rebuild all", there will be a file whose format is "tpy". 54 54 ))) 55 55 58 +**TwinCat 3:** 59 + 60 +~1. In the TwinCat 3, the settings tab of PLC project, select the TPY File option. 61 + 62 +(% style="text-align:center" %) 63 +[[image:PvVEXT2lyv.png]] 64 + 65 +2. Activation configuration 66 + 67 +(% style="text-align:center" %) 68 +[[image:OxqjpdmNDx.png]] 69 + 70 +3.Open the project folder to find the *.tpy file 71 + 72 +(% style="text-align:center" %) 73 +[[image:h5DzS2ZRIk.png]] 74 + 75 +PIStudio Settings 76 + 56 56 Labels mange→ Import Tag From File→ choose the file whose format is "tpy" in the file →Save 57 57 58 58 (% style="text-align:center" %)
- OxqjpdmNDx.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.DevinChen - Size
-
... ... @@ -1,0 +1,1 @@ 1 +92.6 KB - Content
- PvVEXT2lyv.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.DevinChen - Size
-
... ... @@ -1,0 +1,1 @@ 1 +92.9 KB - Content
- h5DzS2ZRIk.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.DevinChen - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.1 KB - Content