1 1  = TwinCAT_PLC_Ethernet =
2 2  
3 -Supported series: Twincat (Currently only suitable for PLCs programmed using TwinCAT 2)
3 +Supported series: Twincat
4 4  
5 -(% style="text-align:center" %)
6 -[[image:RVUyBW3DPV.png]]
5 +**HMI Settings**
7 7  
8 -**PLC Settings**
9 -
10 -Choose Target System→ Search→ Broadcast Search→ choose PLC → Add router→ choose CPU → OK
11 -
12 -(% style="text-align:center" %)
13 -[[image:lTAhpgCBWJ.png]]
14 -
15 -Route Settings→Add Route Dialog→ Broadcast Search→ choose PLC→ modify Route Name as HMI name → modify AmsNetId as HMI AmsNetId: 192.168.50.154.1.1 **(HMI IP + .1.1) **→  select the option of IP Address→ set HMI IP in Address info→ Add Route
16 -
17 -(% style="text-align:center" %)
18 -[[image:gfF9dtMLW7.png]]
19 -
20 -Actions→ Activate configuration
21 -
22 -(% style="text-align:center" %)
23 -[[image:0bvTefCtCv.png]]
24 -
25 -(% id="cke_bm_680S" style="display:none" %)** **(%%)**HMI Settings**
26 -
27 27  |**Item**|**Settings**|**Note**
28 28  |Protocol|TwinCAT_PLC_Ethernet|
29 29  |Connection|Ethernet|
... ... @@ -36,13 +36,28 @@
36 36  (% style="text-align:center" %)
37 37  [[image:0rPAMOoxzH.png]]
38 38  
39 -Setting→PLC IP Address→AMS NetId (Fill in according to the actual AMS NetId search by PLC)
19 +setting→PLC IP Address→AMS NetId
40 40  
41 -**How to import the tags**
21 +(% style="text-align:center" %)
22 +[[image:RVUyBW3DPV.png]]
42 42  
43 -Open TwinCAT PLC Control→ edit program→ save the program in a file → Project → Rebuild all
24 +**PLC Settings**
44 44  
26 +Choose Target System→ Search→ Broadcast Search→ choose PLC → Add router→ choose CPU → OK
27 +
45 45  (% style="text-align:center" %)
29 +[[image:lTAhpgCBWJ.png]]
30 +
31 +Route Settings**→Add Route Dialog→** Broadcast Search→ choose PLC→ modify HMI name → change AmsNetId as 192.168.50.154.1.1 **(HMI IP + .1.1) **→  select the option of IP Address→ set HMI IP in Address info→ Add route
32 +
33 +(% style="text-align:center" %)
34 +[[image:gfF9dtMLW7.png]]
35 +
36 +**how to import the tags**
37 +
38 +Open TwinCAT PLC Control→ edit program→ save the program in a path → Project → Rebuild all
39 +
40 +(% style="text-align:center" %)
46 46  [[image:f925vKrK47.png]]
47 47  
48 48  (% style="text-align:center" %)
... ... @@ -53,25 +53,9 @@
53 53  Note: After "Rebuild all", there will be a file whose format is "tpy".
54 54  )))
55 55  
56 -Labels mange→ Import Tag From File→ choose the file whose format is "tpy" in the file →Save
51 +Labels mange→ Import Tag From File→ choose the file whose format is "tpy" in the path →Save
57 57  
58 58  (% style="text-align:center" %)
59 59  [[image:qaOxmsAR2S.png]]
60 60  
61 -
62 -**Support Variable Type**
63 -
64 -|=Data Type|=PIStudio Data Format|=Range
65 -|=BOOL|Bit|0~~1
66 -|=BYTE|16-bit Unsigned/Binary/BCD/Hex|0~~255
67 -|=WORD|16-bit Unsigned/Binary/BCD/Hex|0~~65535
68 -|=DWORD|32-bit Unsigned/Binary/BCD/Hex |0~~4294967295
69 -|=SINT|16-bit Signed/Binary/BCD/Hex|-128~~127
70 -|=USINT|16-bit Unsigned/Binary/BCD/Hex|0~~255
71 -|=INT|16-bit Signed/Binary/BCD/Hex|-32768~~32767
72 -|=UINT|16-bit Unsigned/Binary/BCD/Hex|0~~65535
73 -|=DINT|32-bit Signed/Binary/BCD/Hex|-2147483648~~2147483647
74 -|=UDINT|32-bit Unsigned/Binary/BCD/Hex|0~~4294967295
75 -|=REAL|32-bit Floating|1.00E-44~~3.40E+38
76 -|=LREAL|64-bit Floating|4.94065645841247e-324~~1.7976931348623157e+308
77 -|=STRING|STRING|
56 +
0bvTefCtCv.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.joe
Size
... ... @@ -1,1 +1,0 @@
1 -54.7 KB
Content