1 1  = TwinCAT_PLC_Ethernet =
2 2  
3 -Supported series: Twincat (Currently only suitable for PLCs programmed using TwinCAT 2)
3 +Supported series: Twincat
4 4  
5 +**HMI Settings**
6 +
7 +|**Item**|**Settings**|**Note**
8 +|Protocol|TwinCAT_PLC_Ethernet|
9 +|Connection|Ethernet|
10 +|Port NO.|48898|
11 +|ADS port|801/811/821/831|
12 +|PLC station No.|1
13 +
14 + Choose protocol: TwinCAT_PLC_Ethernet
15 +
5 5  (% style="text-align:center" %)
17 +[[image:0rPAMOoxzH.png]]
18 +
19 +setting→PLC IP Address→AMS NetId
20 +
21 +(% style="text-align:center" %)
6 6  [[image:RVUyBW3DPV.png]]
7 7  
8 8  **PLC Settings**
... ... @@ -12,7 +12,7 @@
12 12  (% style="text-align:center" %)
13 13  [[image:lTAhpgCBWJ.png]]
14 14  
15 -Route Settings→Add Route Dialog→ Broadcast Search→ choose PLC→ modify Route Name as HMI name → modify AmsNetId as HMI AmsNetId: 192.168.50.154.1.1 **(HMI IP + .1.1) **→  select the option of IP Address→ set HMI IP in Address info→ Add Route
31 +Route Settings→Add Route Dialog→ Broadcast Search→ choose PLC→ modify HMI name → change AmsNetId as HMI AmsNetId: 192.168.50.154.1.1 **(HMI IP + .1.1) **→  select the option of IP Address→ set HMI IP in Address info→ Add route
16 16  
17 17  (% style="text-align:center" %)
18 18  [[image:gfF9dtMLW7.png]]
... ... @@ -22,27 +22,11 @@
22 22  (% style="text-align:center" %)
23 23  [[image:0bvTefCtCv.png]]
24 24  
25 -(% id="cke_bm_680S" style="display:none" %)** **(%%)**HMI Settings**
41 +**how to import the tags**
26 26  
27 -|**Item**|**Settings**|**Note**
28 -|Protocol|TwinCAT_PLC_Ethernet|
29 -|Connection|Ethernet|
30 -|Port NO.|48898|
31 -|ADS port|801/811/821/831|
32 -|PLC station No.|1
43 +Open TwinCAT PLC Control→ edit program→ save the program in a path → Project → Rebuild all
33 33  
34 - Choose protocol: TwinCAT_PLC_Ethernet
35 -
36 36  (% style="text-align:center" %)
37 -[[image:0rPAMOoxzH.png]]
38 -
39 -Setting→PLC IP Address→AMS NetId (Fill in according to the actual AMS NetId search by PLC)
40 -
41 -**How to import the tags**
42 -
43 -Open TwinCAT PLC Control→ edit program→ save the program in a file → Project → Rebuild all
44 -
45 -(% style="text-align:center" %)
46 46  [[image:f925vKrK47.png]]
47 47  
48 48  (% style="text-align:center" %)
... ... @@ -53,7 +53,7 @@
53 53  Note: After "Rebuild all", there will be a file whose format is "tpy".
54 54  )))
55 55  
56 -Labels mange→ Import Tag From File→ choose the file whose format is "tpy" in the file →Save
56 +Labels mange→ Import Tag From File→ choose the file whose format is "tpy" in the path →Save
57 57  
58 58  (% style="text-align:center" %)
59 59  [[image:qaOxmsAR2S.png]]
... ... @@ -72,6 +72,6 @@
72 72  |=UINT|16-bit Unsigned/Binary/BCD/Hex|0~~65535
73 73  |=DINT|32-bit Signed/Binary/BCD/Hex|-2147483648~~2147483647
74 74  |=UDINT|32-bit Unsigned/Binary/BCD/Hex|0~~4294967295
75 -|=REAL|32-bit Floating|1.00E-44~~3.40E+38
76 -|=LREAL|64-bit Floating|4.94065645841247e-324~~1.7976931348623157e+308
75 +|=REAL|32-bit Floating|1.00E~~44,3.40E+38
76 +|=LREAL|64-bit Floating|4.94065645841247e~~324,1.7976931348623157e+308
77 77  |=STRING|STRING|