Changes for page FATEK

Last modified by Hunter on 2023/09/19 15:05

From version 1.1
edited by Hunter
on 2023/09/19 12:00
Change comment: There is no comment for this version
To version 1.4
edited by Hunter
on 2023/09/19 14:45
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -12,3 +12,44 @@
12 12  |Parity|Even|
13 13  |Stop bit|1|
14 14  |PLC station No.|0|
15 +
16 +**Address List**
17 +
18 +(% style="width:1124.22px" %)
19 +|=**Type**|=**Device registers**|=(% style="width: 214px;" %)**Format**|=(% style="width: 166px;" %)**Range**|=(% style="width: 266px;" %)**Note**
20 +|(% colspan="1" rowspan="7" %)Bit|X|(% style="width:214px" %)XDDDDDD|(% style="width:166px" %)0~~999999|(% style="width:266px" %)Input Contact
21 +|Y|(% style="width:214px" %)YDDDDDD|(% style="width:166px" %)0~~999999|(% style="width:266px" %)Output Relay
22 +|M|(% style="width:214px" %)MDDDDDD|(% style="width:166px" %)0~~999999|(% style="width:266px" %)Internal Relay
23 +|S|(% style="width:214px" %)SDDDDDD|(% style="width:166px" %)0~~999999|(% style="width:266px" %)Step Relay
24 +|T|(% style="width:214px" %)TDDDDDD|(% style="width:166px" %)0~~999999|(% style="width:266px" %)Timer "Time-Up" Status Contact
25 +|C|(% style="width:214px" %)CDDDDDD|(% style="width:166px" %)0~~999999|(% style="width:266px" %)Counter "Count-Up" Status Contact
26 +|(% colspan="1" %)Z|(% style="width:214px" %)ZD|(% style="width:166px" %)0|(% style="width:266px" %)
27 +|(% colspan="1" rowspan="10" %)Word|(% colspan="1" %)D|(% colspan="1" style="width:214px" %)DDDDDDD|(% style="width:166px" %)0~~999999|(% style="width:266px" %)Data Register
28 +|(% colspan="1" %)R|(% colspan="1" style="width:214px" %)RDDDDDD|(% colspan="1" style="width:166px" %)0~~999999|(% style="width:266px" %)
29 +|(% colspan="1" %)WX|(% colspan="1" style="width:214px" %)WXDDDDDD|(% colspan="1" style="width:166px" %)0~~999999|(% colspan="1" style="width:266px" %)Input Register(IR)
30 +|(% colspan="1" %)WY|(% colspan="1" style="width:214px" %)WYDDDDDD|(% colspan="1" style="width:166px" %)0~~999999|(% colspan="1" style="width:266px" %)Output Register(OR)
31 +|(% colspan="1" %)WM|(% colspan="1" style="width:214px" %)WMDDDDDD|(% colspan="1" style="width:166px" %)0~~999999|(% colspan="1" style="width:266px" %)
32 +|(% colspan="1" %)WS|(% colspan="1" style="width:214px" %)WSDDDDDD|(% colspan="1" style="width:166px" %)0~~999999|(% colspan="1" style="width:266px" %)
33 +|(% colspan="1" %)RT|(% colspan="1" style="width:214px" %)RTDDDDDD|(% colspan="1" style="width:166px" %)0~~999999|(% colspan="1" style="width:266px" %)Timer Register
34 +|(% colspan="1" %)RC|(% colspan="1" style="width:214px" %)RCDDDDDD|(% colspan="1" style="width:166px" %)0~~999999|(% colspan="1" style="width:266px" %)Counter Register
35 +|(% colspan="1" %)DRT|(% colspan="1" style="width:214px" %)DRTDDDDDD|(% colspan="1" style="width:166px" %)0~~999999|(% colspan="1" style="width:266px" %)Double Word Timer Register
36 +|(% colspan="1" %)DRC|(% colspan="1" style="width:214px" %)DRCDDDDDD|(% colspan="1" style="width:166px" %)0~~999999|(% colspan="1" style="width:266px" %)Double Word Counter Register
37 +
38 +**PLC Settings**
39 +
40 +Create new project, and naming the project, select the specific model according to the actual PLC.
41 +
42 +(% style="text-align:center" %)
43 +[[image:WPLadd01Createnew.png]]
44 +
45 +Program the PLC
46 +
47 +(% style="text-align:center" %)
48 +[[image:WPLadd02Programming.png]]
49 +
50 +Connect the PLC to PC by RS232-USB converter cable, and online PLC by using the Auto Check function.
51 +
52 +(% style="text-align:center" %)
53 +[[image:WPLadd03onlinePLC.png]]
54 +
55 +
WPLadd01Createnew.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +32.5 KB
Content
WPLadd02Programming.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +10.6 KB
Content
WPLadd03onlinePLC.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +58.3 KB
Content