... |
... |
@@ -180,71 +180,3 @@ |
180 |
180 |
|
181 |
181 |
(% style="text-align:center" %) |
182 |
182 |
[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png||alt="CommonEthernet.png" height="170" width="401"]] |
183 |
|
- |
184 |
|
-== INOVANCE H5U Ethernet FreeTag == |
185 |
|
- |
186 |
|
-Support Series: INOVANCE H5U Series |
187 |
|
- |
188 |
|
-**HMI Settings** |
189 |
|
- |
190 |
|
-|=**Item**|=**Settings**|=**Note** |
191 |
|
-|Protocol|INOVANCE H5U PLC Ethernet FreeTag| |
192 |
|
-|Connection|Ethernet| |
193 |
|
-|Port No.|12939| |
194 |
|
-|Device No.|1| |
195 |
|
-|HMI No.|0| |
196 |
|
- |
197 |
|
-|**Data Types**|**Keywords**|**Number**|**Note** |
198 |
|
-|BOOL|BOOL|1|FALSE(0) or TRUE(1) |
199 |
|
-|BYTE|BYTE|8|0~~255 |
200 |
|
-|INT|INT|16|-32768~~32767 |
201 |
|
-|DINT|DINT|32|-2147483648~~2147483647 |
202 |
|
-|REAL|REAL|32|-3.402823466E+38~~3.402823466E+38 |
203 |
|
-|ARRAY|ARRAY| |Supported data types are Bool, Byte, Int, Dint, Real |
204 |
|
- |
205 |
|
-**PLC Settings** |
206 |
|
- |
207 |
|
-1.Click [Tools]→Click [Communication Settings]. |
208 |
|
- |
209 |
|
-(% style="text-align:center" %) |
210 |
|
-[[image:1(1)(1).png]] |
211 |
|
- |
212 |
|
-2.Select PLC model→ [OK] |
213 |
|
- |
214 |
|
-(% style="text-align:center" %) |
215 |
|
-[[image:1727144142576-438.png]] |
216 |
|
- |
217 |
|
-3.Select communication type →Click [Search]→[Test]→[OK]→[YES]. |
218 |
|
- |
219 |
|
-(% style="text-align:center" %) |
220 |
|
-[[image:1727144142577-386.png]] |
221 |
|
- |
222 |
|
- |
223 |
|
-(% style="text-align:center" %) |
224 |
|
-[[image:1727144142578-816.png]] |
225 |
|
- |
226 |
|
-**New project** |
227 |
|
- |
228 |
|
-1.Click[Create a new project] |
229 |
|
- |
230 |
|
-[[image:1727144286930-299.png]] |
231 |
|
- |
232 |
|
-2.Edit Project Name→ Select storage location → Click [OK]. |
233 |
|
- |
234 |
|
-(% style="text-align:center" %) |
235 |
|
-[[image:1727144286937-233.png]] |
236 |
|
- |
237 |
|
-**Create a new tag** |
238 |
|
- |
239 |
|
-1.Right click[Variable-Table]→Click [New Global Variable Table]. |
240 |
|
- |
241 |
|
-[[image:1727144337844-328.png]] |
242 |
|
- |
243 |
|
-2.Add tags→Click [Compile]→Click [Export HMI Monitoring Variable Table] |
244 |
|
- |
245 |
|
-[[image:1727144337852-839.png]] |
246 |
|
- |
247 |
|
-3.Edit File Name→[Save] |
248 |
|
- |
249 |
|
-(% style="text-align:center" %) |
250 |
|
-[[image:1727144337866-355.png]] |