Changes for page Limitation of the Ethernet communication protocol
Last modified by Devin Chen on 2025/02/22 11:16
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -17,10 +17,19 @@ 17 17 (expect -O models)|16|4|2 18 18 |=PI8000ig Series|32|6|2 19 19 20 += PIStudio Version Limit Differences for FreeTag protocol = 20 20 21 -|= |=8.2.95.22092802|=8.4.66.23102001|=Upcoming Release 22 -|= | | | 23 -|= | | | 24 -|= | | | 22 +(% style="width:1470px" %) 23 +|=(% style="width: 184px;" %)PIStudio Version|=(% colspan="2" style="width: 382px;" %)8.2.95.22092802|=(% colspan="2" style="width: 417px;" %)8.4.66.23102001|=(% colspan="2" style="width: 469px;" %)Upcoming Release 24 +|=(% style="width: 184px;" %)Protocol|(% style="width:178px" %)Wecon FreeTag Protocol(6C & 6V)|(% style="width:204px" %)3rd Party Manufacturer FreeTag|(% style="width:205px" %)Wecon FreeTag Protocol(6C & 6V)|(% style="width:212px" %)3rd Party Manufacturer FreeTag|(% style="width:249px" %)Wecon FreeTag Protocol(6C & 6V)|(% style="width:220px" %)3rd Party Manufacturer FreeTag 25 +|=(% style="width: 184px;" %)PI3043ieS-N|(% style="width:178px" %)YES|(% style="width:204px" %)YES|(% style="width:205px" %)N/A|(% style="width:212px" %)N/A|(% style="width:249px" %)N/A|(% style="width:220px" %)N/A 26 +|=(% style="width: 184px;" %)PI3070ig-O &PI3102ig-O|(% style="width:178px" %)YES|(% style="width:204px" %)YES|(% style="width:205px" %)N/A|(% style="width:212px" %)N/A|(% style="width:249px" %)YES|(% style="width:220px" %)N/A 27 +|=(% style="width: 184px;" %)PI3000ig Series 28 +(expect -O models)|(% style="width:178px" %)YES|(% style="width:204px" %)YES|(% style="width:205px" %)YES|(% style="width:212px" %)YES|(% style="width:249px" %)YES|(% style="width:220px" %)N/A 29 +|=(% style="width: 184px;" %)PI8000ig|(% style="width:178px" %)YES|(% style="width:204px" %)YES|(% style="width:205px" %)YES|(% style="width:212px" %)YES|(% style="width:249px" %)YES|(% style="width:220px" %)YES 25 25 31 +{{info}} 32 +✎Note: The Wecon Free Tag protocol specifically refers to the "WECON LX6V FreeTag Ethernet" and "CODESYS V3". So for example at the columns for Upcoming Release, all models from 3000ig **CAN ONLY** use CODESYS V3 to communicate with LX6C, but not able to use CODESYS V3 to communicate with any other CODESYS devices. And please notice that once update the firmware with the newer version, it cannot downgrade with older version PIStudio anymore. 33 +{{/info}} 34 + 26 26