Changes for page Limitation of the Ethernet communication protocol
Last modified by Devin Chen on 2025/02/22 11:16
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.joe - Content
-
... ... @@ -3,19 +3,19 @@ 3 3 The table below shows the maximum number of communications configured for the general protocol, Free Tag Protocol and CodeSys V3 Protocol on each series model. 4 4 **~ (~*~*Only HMI V2.0 System supports Free Tag Protocol and CodeSys V3 Protocol~*~*)** 5 5 6 -|=HMI Series|=General Protocol |=FreeTags Protocol|=CodeSys V3 Protocol7 -|=General 3000 Series|16 |N/A|N/A8 -|=General 8000 Series|24 |4|N/A9 -|=General 9000 Series|32 |N/A|N/A10 -|=PI3000i Series|16 |N/A|N/A6 +|=HMI Series|=General Protocol 7 +|=General 3000 Series|16 8 +|=General 8000 Series|24 9 +|=General 9000 Series|32 10 +|=PI3000i Series|16 11 11 |=PI3000ie Series 12 - (PI3043ieS-N)|16 |2|N/A12 + (PI3043ieS-N)|16 13 13 |=PI3000ie Series 14 - (other model)|N/A |N/A|N/A15 -|= PI3070ig-O & PI3102ig-O|16 |N/A|N/A14 + (other model)|N/A 15 +|= PI3070ig-O & PI3102ig-O|16 16 16 |=PI3000ig Series 17 - (except -O models)|16 |4|218 -|=PI8000ig Series|32 |6|217 + (except -O models)|16 18 +|=PI8000ig Series|32 19 19 20 20 = PIStudio Version Limit Differences for FreeTag protocol = 21 21 ... ... @@ -59,4 +59,21 @@ 59 59 ✎Note: YES(2.0)* means the 3000ig Series only support 3rd party manufacturer on HMI V2.0 system, but will not available after upgrade into HMI V3.0. 60 60 {{/info}} 61 61 62 - 62 += **The number of FreeTag Protocol on HMI Series** = 63 + 64 + 65 +|=(% style="width: 300px;" %)Protocol|=(% style="width: 155px;" %)RH Series|=(% style="width: 171px;" %)RE Series|=(% style="width: 193px;" %)PI3000ig Series|=(% style="width: 184px;" %)PI8000ig Series|=(% style="width: 158px;" %)PI3000ie Series|=(% style="width: 174px;" %)PI3000i Series|=(% style="width: 119px;" %)IN Series 66 +|=(% style="width: 300px;" %)CODESYS V3|(% style="width:155px" %)2|(% style="width:171px" %)N/A|(% style="width:193px" %)2|(% style="width:184px" %)2|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 67 +|=(% style="width: 300px;" %)WECON LX6V|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)4|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 68 +|=(% style="width: 300px;" %)INOVANCE H5U FreeTag|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)6(2.0)*|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 69 +|=(% style="width: 300px;" %)OMRON NX/NJ|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)6(2.0)*|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 70 +|=(% style="width: 300px;" %)Rockwell CompactLogix|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)6(2.0)*|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 71 +|=(% style="width: 300px;" %)Rockwell Micro850|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)6(2.0)*|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 72 +|=(% style="width: 300px;" %)SiemensS7-1200/S7-1500 FreeTag|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)N/A|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 73 +|=(% style="width: 300px;" %)OPC UA Client|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)N/A|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 74 +|=(% style="width: 300px;" %)BECKHOFF TwinCAT|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)N/A|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 75 + 76 +(% class="box infomessage" %) 77 +((( 78 +Note: The above number is recommended number. The operating speed of HMI may be slow after exceeding the number. 79 +)))