Changes for page Limitation of the Ethernet communication protocol
Last modified by Devin Chen on 2025/02/22 11:16
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -3,6 +3,7 @@ 3 3 The table below shows the maximum number of communications configured for the general protocol, Free Tag Protocol and CodeSys V3 Protocol on each series model. 4 4 **~ (~*~*Only HMI V2.0 System supports Free Tag Protocol and CodeSys V3 Protocol~*~*)** 5 5 6 +(% style="margin-left:auto; margin-right:auto; width:600px" %) 6 6 |=HMI Series|=General Protocol 7 7 |=General 3000 Series|16 8 8 |=General 8000 Series|24 ... ... @@ -31,7 +31,7 @@ 31 31 )))|(% style="width:157px" %)YES|(% style="width:154px" %)YES|(% style="width:157px" %)YES|(% style="width:184px" %)YES|(% style="width:197px" %)YES|(% style="width:188px" %)N/A 32 32 |=(% style="width: 285px;" %)PI8000ig|(% style="width:157px" %)YES|(% style="width:154px" %)YES|(% style="width:157px" %)YES|(% style="width:184px" %)YES|(% style="width:197px" %)YES|(% style="width:188px" %)YES 33 33 34 -(% class="box warningmessage" %)35 +(% class="box successmessage" %) 35 35 ((( 36 36 ✎Note: **Since CODESYS V3 was released in version 8.4.66.23102001, only the LX6V FreeTag protocol is available in version 8.2.95.22082802.** The Wecon Free Tag protocol specifically refers to the "WECON LX6V FreeTag Ethernet" and "CODESYS V3". 37 37 The list of 3rd-party manufacturers' FreeTag protocols is as follows: ... ... @@ -44,8 +44,6 @@ 44 44 7. BECKHOFF TwinCAT 45 45 46 46 The model suffix (x) means there are optional (G), (W), (AG) model. 47 - 48 - 49 49 ))) 50 50 51 51 = **FreeTag Protocols Quantity Recommendation on HMI Series** = ... ... @@ -62,7 +62,13 @@ 62 62 |=(% style="width: 300px;" %)OPC UA Server*|(% style="width:155px" %)N/A|(% style="width:171px" %)N/A|(% style="width:193px" %)N/A|(% style="width:184px" %)YES|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 63 63 |=(% style="width: 300px;" %)BECKHOFF TwinCAT|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)N/A|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 64 64 65 -{{info}} 64 +(% class="box floatinginfobox" %) 65 +((( 66 + 67 +))) 68 + 69 +(% class="box successmessage" %) 70 +((( 66 66 ✎Note: 67 67 68 68 1. N/A* means this series does not support the corresponding protocol ... ... @@ -72,7 +72,7 @@ 72 72 3. The OPC UA Server is configured through the Data tool, not the Communication parameter settings. **Only one configuration is valid**, so the recommended quantity for creating protocols is not applicable to the OPC UA Server. 73 73 74 74 4. 75 - {{/info}}80 +))) 76 76 77 77 |=(% style="width: 300px;" %)Protocol|=(% style="width: 155px;" %)RH Series|=(% style="width: 171px;" %)RE Series|=(% style="width: 193px;" %)PI3000ig Series|=(% style="width: 184px;" %)PI8000ig Series|=(% style="width: 158px;" %)PI3000ie Series|=(% style="width: 174px;" %)PI3000i Series|=(% style="width: 119px;" %)IN Series 78 78 |=(% style="width: 300px;" %)CODESYS V3|(% style="width:155px" %)2|(% style="width:171px" %)N/A|(% style="width:193px" %)2|(% style="width:184px" %)2|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A ... ... @@ -85,7 +85,7 @@ 85 85 |=(% style="width: 300px;" %)OPC UA Client|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)N/A|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 86 86 |=(% style="width: 300px;" %)BECKHOFF TwinCAT|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)N/A|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 87 87 88 -(% class="box infomessage" %)93 +(% class="box successmessage" %) 89 89 ((( 90 -Note: The above number is recommended number. The operating speed of HMI may be slow after exceeding the number. 95 +Note: The above number is recommended number. The operating speed of HMI may be slow after exceeding the number. 91 91 )))