Last modified by Devin Chen on 2025/02/22 11:16

From version 44.1
edited by Mora Zhou
on 2025/01/16 11:16
Change comment: There is no comment for this version
To version 46.1
edited by Mora Zhou
on 2025/01/16 11:18
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -31,7 +31,7 @@
31 31  )))|(% style="width:157px" %)YES|(% style="width:154px" %)YES|(% style="width:157px" %)YES|(% style="width:184px" %)YES|(% style="width:197px" %)YES|(% style="width:188px" %)N/A
32 32  |=(% style="width: 285px;" %)PI8000ig|(% style="width:157px" %)YES|(% style="width:154px" %)YES|(% style="width:157px" %)YES|(% style="width:184px" %)YES|(% style="width:197px" %)YES|(% style="width:188px" %)YES
33 33  
34 -(% class="box warningmessage" %)
34 +(% class="box successmessage" %)
35 35  (((
36 36  ✎Note: **Since CODESYS V3 was released in version 8.4.66.23102001, only the LX6V FreeTag protocol is available in version 8.2.95.22082802.** The Wecon Free Tag protocol specifically refers to the "WECON LX6V FreeTag Ethernet" and "CODESYS V3".
37 37  The list of 3rd-party manufacturers' FreeTag protocols is as follows:
... ... @@ -44,8 +44,6 @@
44 44  7. BECKHOFF TwinCAT
45 45  
46 46  The model suffix (x) means there are optional (G), (W), (AG) model.
47 -
48 -
49 49  )))
50 50  
51 51  = **FreeTag Protocols Quantity Recommendation on HMI Series** =
... ... @@ -64,8 +64,13 @@
64 64  
65 65  (% class="box floatinginfobox" %)
66 66  (((
67 - ✎Note:
65 +
66 +)))
68 68  
68 +(% class="box successmessage" %)
69 +(((
70 +✎Note:
71 +
69 69  1. N/A* means this series does not support the corresponding protocol
70 70  
71 71  2. (2.0)* means the 3000ig Series only support 3rd party manufacturer on HMI V2.0 system, but will not available after upgrade into HMI V3.0.
... ... @@ -75,7 +75,6 @@
75 75  4.
76 76  )))
77 77  
78 -
79 79  |=(% style="width: 300px;" %)Protocol|=(% style="width: 155px;" %)RH Series|=(% style="width: 171px;" %)RE Series|=(% style="width: 193px;" %)PI3000ig Series|=(% style="width: 184px;" %)PI8000ig Series|=(% style="width: 158px;" %)PI3000ie Series|=(% style="width: 174px;" %)PI3000i Series|=(% style="width: 119px;" %)IN Series
80 80  |=(% style="width: 300px;" %)CODESYS V3|(% style="width:155px" %)2|(% style="width:171px" %)N/A|(% style="width:193px" %)2|(% style="width:184px" %)2|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
81 81  |=(% style="width: 300px;" %)WECON LX6V|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)4|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
... ... @@ -87,7 +87,7 @@
87 87  |=(% style="width: 300px;" %)OPC UA Client|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)N/A|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
88 88  |=(% style="width: 300px;" %)BECKHOFF TwinCAT|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)N/A|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
89 89  
90 -(% class="box infomessage" %)
92 +(% class="box successmessage" %)
91 91  (((
92 -Note: The above number is recommended number. The operating speed of HMI may be slow after exceeding the number.
94 +Note: The above number is recommended number. The operating speed of HMI may be slow after exceeding the number.
93 93  )))