Changes for page Limitation of the Ethernet communication protocol
Last modified by Devin Chen on 2025/02/22 11:16
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Mora1 +XWiki.Hunter - Content
-
... ... @@ -72,22 +72,5 @@ 72 72 73 73 3. The OPC UA Server is configured through the Data tool, not the Communication parameter settings. **Only one configuration is valid**, so the recommended quantity for creating protocols is not applicable to the OPC UA Server. 74 74 75 -4. 75 +4. All the numbers above represent the recommended quantity for creating protocols. Communication speed may be delayed if the number exceeds the recommended limit. 76 76 ))) 77 - 78 -(% cellspacing="150" style="margin-left:auto; margin-right:auto; width:1200px" %) 79 -|=(% style="width: 300px;" %)Protocol|=(% style="width: 155px;" %)RH Series|=(% style="width: 171px;" %)RE Series|=(% style="width: 193px;" %)PI3000ig Series|=(% style="width: 184px;" %)PI8000ig Series|=(% style="width: 158px;" %)PI3000ie Series|=(% style="width: 174px;" %)PI3000i Series|=(% style="width: 119px;" %)IN Series 80 -|=(% style="width: 300px;" %)CODESYS V3|(% style="width:155px" %)2|(% style="width:171px" %)N/A|(% style="width:193px" %)2|(% style="width:184px" %)2|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 81 -|=(% style="width: 300px;" %)WECON LX6V|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)4|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 82 -|=(% style="width: 300px;" %)INOVANCE H5U FreeTag|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)6(2.0)*|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 83 -|=(% style="width: 300px;" %)OMRON NX/NJ|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)6(2.0)*|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 84 -|=(% style="width: 300px;" %)Rockwell CompactLogix|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)6(2.0)*|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 85 -|=(% style="width: 300px;" %)Rockwell Micro850|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)6(2.0)*|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 86 -|=(% style="width: 300px;" %)SiemensS7-1200/S7-1500 FreeTag|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)N/A|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 87 -|=(% style="width: 300px;" %)OPC UA Client|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)N/A|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 88 -|=(% style="width: 300px;" %)BECKHOFF TwinCAT|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)N/A|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A 89 - 90 -(% class="box successmessage" %) 91 -((( 92 -Note: The above number is recommended number. The operating speed of HMI may be slow after exceeding the number. 93 -)))