Last modified by Devin Chen on 2025/02/22 11:16

From version 52.1
edited by Hunter
on 2025/01/16 11:44
Change comment: There is no comment for this version
To version 51.1
edited by Hunter
on 2025/01/16 11:39
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -72,5 +72,22 @@
72 72  
73 73  3. The OPC UA Server is configured through the Data tool, not the Communication parameter settings. **Only one configuration is valid**, so the recommended quantity for creating protocols is not applicable to the OPC UA Server.
74 74  
75 -4. All the numbers above represent the recommended quantity for creating protocols. Communication speed may be delayed if the number exceeds the recommended limit.
75 +4. All the numbers above represent the recommended quantity for creating protocols. Communication speed may be delayed if the number exceeds the recommended limit.
76 76  )))
77 +
78 +(% cellspacing="150" style="margin-left:auto; margin-right:auto; width:1200px" %)
79 +|=(% style="width: 300px;" %)Protocol|=(% style="width: 155px;" %)RH Series|=(% style="width: 171px;" %)RE Series|=(% style="width: 193px;" %)PI3000ig Series|=(% style="width: 184px;" %)PI8000ig Series|=(% style="width: 158px;" %)PI3000ie Series|=(% style="width: 174px;" %)PI3000i Series|=(% style="width: 119px;" %)IN Series
80 +|=(% style="width: 300px;" %)CODESYS V3|(% style="width:155px" %)2|(% style="width:171px" %)N/A|(% style="width:193px" %)2|(% style="width:184px" %)2|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
81 +|=(% style="width: 300px;" %)WECON LX6V|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)4|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
82 +|=(% style="width: 300px;" %)INOVANCE H5U FreeTag|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)6(2.0)*|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
83 +|=(% style="width: 300px;" %)OMRON NX/NJ|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)6(2.0)*|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
84 +|=(% style="width: 300px;" %)Rockwell CompactLogix|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)6(2.0)*|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
85 +|=(% style="width: 300px;" %)Rockwell Micro850|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)6(2.0)*|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
86 +|=(% style="width: 300px;" %)SiemensS7-1200/S7-1500 FreeTag|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)N/A|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
87 +|=(% style="width: 300px;" %)OPC UA Client|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)N/A|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
88 +|=(% style="width: 300px;" %)BECKHOFF TwinCAT|(% style="width:155px" %)6|(% style="width:171px" %)N/A|(% style="width:193px" %)N/A|(% style="width:184px" %)6|(% style="width:158px" %)N/A|(% style="width:174px" %)N/A|(% style="width:119px" %)N/A
89 +
90 +(% class="box successmessage" %)
91 +(((
92 +Note: The above number is recommended number. The operating speed of HMI may be slow after exceeding the number.
93 +)))