Hunter 2.1 1 = {{id name="HLimitationoftheEthernetcommunicationprotocol"/}}Limitation of the Ethernet communication protocol =
2
Mora Zhou 10.2 3 The table below shows the maximum number of communications configured for the general protocol, Free Tag Protocol and CodeSys V3 Protocol on each series model.
4 **~ (~*~*Only HMI V2.0 System supports Free Tag Protocol and CodeSys V3 Protocol~*~*)**
Hunter 2.1 5
6 |=HMI Series|=General Protocol|=FreeTags Protocol|=CodeSys V3 Protocol
7 |=General 3000 Series|16|N/A|N/A
8 |=General 8000 Series|24|4|N/A
9 |=General 9000 Series|32|N/A|N/A
10 |=PI3000i Series|16|N/A|N/A
11 |=PI3000ie Series
12 (PI3043ieS-N)|16|2|N/A
13 |=PI3000ie Series
14 (other model)|N/A|N/A|N/A
Hunter 2.4 15 |= PI3070ig-O & PI3102ig-O|16|N/A|N/A
Hunter 2.1 16 |=PI3000ig Series
Mora Zhou 10.2 17 (except -O models)|16|4|2
Hunter 2.1 18 |=PI8000ig Series|32|6|2
Hunter 2.4 19
Hunter 6.1 20 = PIStudio Version Limit Differences for FreeTag protocol =
Hunter 3.2 21
Hunter 3.1 22 (% style="width:1470px" %)
Hunter 14.1 23 |=(% style="width: 184px;" %)PIStudio Version|=(% colspan="2" style="width: 382px;" %)8.2.95.22092802|=(% colspan="2" style="width: 417px;" %)8.4.66.23102001
24 |=(% style="width: 184px;" %)Protocol|(% style="width:178px" %)Wecon LX6V FreeTag |(% style="width:204px" %)3rd Party Manufacturer FreeTag|(% style="width:205px" %)Wecon FreeTag Protocol(6C & 6V)|(% style="width:212px" %)3rd Party Manufacturer FreeTag
25 |=(% style="width: 184px;" %)PI3043ieS-N|(% style="width:178px" %)YES|(% style="width:204px" %)YES|(% style="width:205px" %)N/A|(% style="width:212px" %)N/A
26 |=(% style="width: 184px;" %)PI3070ig-O &PI3102ig-O|(% style="width:178px" %)YES|(% style="width:204px" %)YES|(% style="width:205px" %)N/A|(% style="width:212px" %)N/A
Hunter 3.1 27 |=(% style="width: 184px;" %)PI3000ig Series
Hunter 14.1 28 (except -O models)|(% style="width:178px" %)YES|(% style="width:204px" %)YES|(% style="width:205px" %)YES|(% style="width:212px" %)YES
29 |=(% style="width: 184px;" %)PI8000ig|(% style="width:178px" %)YES|(% style="width:204px" %)YES|(% style="width:205px" %)YES|(% style="width:212px" %)YES
Hunter 2.4 30
Hunter 7.1 31 {{info}}
Hunter 8.1 32 ✎Note: The Wecon Free Tag protocol specifically refers to the "WECON LX6V FreeTag Ethernet" and "CODESYS V3". So for example at the columns for Upcoming Release, all models from 3000ig **CAN ONLY** use CODESYS V3 to communicate with LX6C, but not able to use CODESYS V3 to communicate with any other CODESYS devices. And please notice that once update the firmware with the newer version, it cannot downgrade with older version PIStudio anymore.