Wecon 1.1 1 = {{id name="HOmron"/}}**Omron** =
2
3 == **CJ2M Series Ethemet** ==
4
5 Supported device:CJ series, CJ1W-EIP21,CJ2M-EIP21
6
7 **HMI Settings**
8
9 |=**Items**|=**Settings**
10 |Protocol|OMRON CJ TCP FINS Ethemet
11 |Connection|Ethernet
12 |Port No.|9600
13 |Device No.|0
14 |HMI No.|0
15
16 (% id="cke_bm_1048S" style="display:none" %)** **
17
18 **Address List**
19
20 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
21 |(% colspan="1" rowspan="23" %)Bit|CIO|CIO|CIO d|0~~99999|
22 |W|W|W d|0~~99999|
23 |D|D|D d|0~~99999|
24 |H|H|H d|0~~99999|
25 |A|A|A d|0~~99999|
26 |T|T|T h|0~~99999|
27 |CF|CF|CF d|0~~99999|
28 |FF|FF|FF d|0~~99999|
29 |C|C|C d|0~~99999|
30 |EM0|EM0|EM0 d|0~~99999|
31 |EM1|EM1|EM1 d|0~~99999|
32 |EM2|EM2|EM2 d|0~~99999|
33 |EM3|EM3|EM3 d|0~~99999|
34 |EM4|EM4|EM4 d|0~~99999|
35 |EM5|EM5|EM5 h|0~~99999|
36 |EM6|EM6|EM6 d|0~~99999|
37 |EM7|EM7|EM7 d|0~~99999|
38 |EM8|EM8|EM8 d|0~~99999|
39 |EM9|EM9|EM9 d|0~~99999|
40 |EMA|EMA|EMA d|0~~99999|
41 |EMB|EMB|EMB d|0~~99999|
42 |EMC|EMC|EMC d|0~~99999|
43 |Lamp|Lamp|Lamp d|0~~0|
44 |(% colspan="1" rowspan="24" %)Word|CIO|CIO|CIO d|0~~99999|
45 |W|W|W d|0~~99999|
46 |D|D|D d|0~~99999|
47 |H|H|H d|0~~99999|
48 |A|A|A d|0~~99999|
49 |T|T|T h|0~~99999|
50 |CF|CF|CF d|0~~99999|
51 |FF|FF|FF d|0~~99999|
52 |C|C|C d|0~~99999|
53 |EM0|EM0|EM0 d|0~~99999|
54 |EM1|EM1|EM1 d|0~~99999|
55 |EM2|EM2|EM2 d|0~~99999|
56 |EM3|EM3|EM3 d|0~~99999|
57 |EM4|EM4|EM4 d|0~~99999|
58 |EM5|EM5|EM5 h|0~~99999|
59 |EM6|EM6|EM6 d|0~~99999|
60 |EM7|EM7|EM7 d|0~~99999|
61 |EM8|EM8|EM8 d|0~~99999|
62 |EM9|EM9|EM9 d|0~~99999|
63 |EMA|EMA|EMA d|0~~99999|
64 |EMB|EMB|EMB d|0~~99999|
65 |EMC|EMC|EMC d|0~~99999|
66 |IR|IR|IR d|0~~99999|
67 |DR|DR|DR d|0~~99999|
68
69 **Configure the communication protocol**
70
71 {{id name="Iimage-20220830143348-1.png"/}}
72
73 (% style="text-align:center" %)
74 [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_95df6576665b7885.png||alt="image-20220830143348-1.png" height="735" width="616"]]
75
76 {{id name="Iimage-20220830143511-2.png"/}}
77
78 (% style="text-align:center" %)
79 [[image:2.3.2.png]]
80
81 **PLC Setting:**
82
83 ①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
84 Note:The IP address of the PLC is displayed on the LED when the PLC is powered up
85
86 (% style="text-align:center" %)
87 [[image:1.3.1.png]]
88
89 ②[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
90
91 (% style="text-align:center" %)
92 [[image:1.3.2.png]]
93
94 ③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
95
96 [IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0.
97 Note: Please configure the IP parameters of PLC according to the field needs
98
99 (% style="text-align:center" %)
100 [[image:1.4.png]]
101
102 ④Two rotary coding switches should be set depanding on the program paremeter:
103 a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0
104
105 (% style="text-align:center" %)
106 [[image:WeCom Screenshot_20230828090604.png]]
107
108
109 **b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.**
110
111
112 (% style="text-align:center" %)
113 [[image:WeCom.png]]
114
115 **Cable Wiring**
116
117 Pin Definition Diagram
118
119 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-3"/}}
120
121 (% style="text-align:center" %)
122 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
123
124 == {{id name="HCS128CP1E2FCP1H29"/}}**CP1E Series Serial ** ==
125
126 Supported device: OMRON CS1(CP1E/CP1H)
127
128 **HMI Settings**
129
130 |=**Items**|=**Settings**|=**Note**
131 |Protocol|OMRON CS1(CP1E/CP1H)|
132 |Connection|RS232 (9600, 2, 7, EVEN)|
133 |Port No.|None|
134 |PLC station No.|0|
135
136 **Address List**
137
138 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
139 |(% colspan="1" rowspan="22" %)Bit|CIO|CIO|CIO d|0~~99999|
140 |W|W|W d|0~~99999|
141 |D|D|D d|0~~99999|
142 |H|H|H d|0~~99999|
143 |A|A|A d|0~~99999|
144 |TF|T|T h|0~~99999|
145 |CF|CF|CF d|0~~99999|
146 |T|FF|FF d|0~~99999|
147 |C|C|C d|0~~99999|
148 |EM0|EM0|EM0 d|0~~99999|
149 |EM1|EM1|EM1 d|0~~99999|
150 |EM2|EM2|EM2 d|0~~99999|
151 |EM3|EM3|EM3 d|0~~99999|
152 |EM4|EM4|EM4 d|0~~99999|
153 |EM5|EM5|EM5 h|0~~99999|
154 |EM6|EM6|EM6 d|0~~99999|
155 |EM7|EM7|EM7 d|0~~99999|
156 |EM8|EM8|EM8 d|0~~99999|
157 |EM9|EM9|EM9 d|0~~99999|
158 |EMA|EMA|EMA d|0~~99999|
159 |EMB|EMB|EMB d|0~~99999|
160 |EMC|EMC|EMC d|0~~99999|
161 |(% colspan="1" rowspan="23" %)Word|CIO|CIO|CIO d|0~~99999|
162 |W|W|W d|0~~99999|
163 |D|D|D d|0~~99999|
164 |H|H|H d|0~~99999|
165 |A|A|A d|0~~99999|
166 |T|T|T h|0~~99999|
167 |CIO|CF|CF d|0~~99999|
168 |C|C|C d|0~~99999|
169 |EM0|EM0|EM0 d|0~~99999|
170 |EM1|EM1|EM1 d|0~~99999|
171 |EM2|EM2|EM2 d|0~~99999|
172 |EM3|EM3|EM3 d|0~~99999|
173 |EM4|EM4|EM4 d|0~~99999|
174 |EM5|EM5|EM5 h|0~~99999|
175 |EM6|EM6|EM6 d|0~~99999|
176 |EM7|EM7|EM7 d|0~~99999|
177 |EM8|EM8|EM8 d|0~~99999|
178 |EM9|EM9|EM9 d|0~~99999|
179 |EMA|EMA|EMA d|0~~99999|
180 |EMB|EMB|EMB d|0~~99999|
181 |EMC|EMC|EMC d|0~~99999|
182 |IR|IR|IR d|0~~99999|
183 |DR|DR|DR d|0~~99999|
184
185 **Configure the communication protocol**
186
187 {{id name="Iimage-20220902153118-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4acef6476c6f9de3.png||alt="image-20220902153118-1.png" height="735" width="616"]]
188
189 {{id name="Iimage-20220902151322-2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4f9620139b8a44b3.png||alt="image-20220902151322-2.png" height="905" width="1038"]]
190
191 **{{id name="cke_bm_27437S"/}} PLC Settings(CX-Programmer)**
192
193 Open cx-programmer, create a new PLC project or open the project that has been created.
194 Create new project: [File]→[New]→[Device Type]CP1E→[settings]→[General]→[CPU Type]N30→[OK]→[OK].
195
196 {{id name="I1.25DE57A0B65B05EFAD.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_aa70463d933c7549.png||alt="1.2 工程新建D.png" height="660" width="1134"]]
197
198 PLC Default Parameters:[Settings]→[Built-in RS232C Port]→[Communication Settings]→[Standard]9600,1,7,2,E means:[Baud rate] 9600, [Data bits]7, [Stop bits] 2,[Parity] EVEN→[Unit Number]0 →[Mode]Host Link(Defaut).
199
200 {{id name="I1.34E3253E353C26570768467E5770B-914D7F6ED.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_84484fbbb00ca61.png||alt="1.3 串口参数的查看-配置D.png" height="660" width="1134"]]
201
202 **Cable Wiring**
203
204 {{id name="I56FE72473.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4c5480a409965d39.png||alt="image-20220902153949-2.png" height="508" width="2014"]]
205
206 Pin Definition Diagram
207
208 {{id name="I3.1.263A553E3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ad6138e6812c2253.png||alt="image-20220902154056-3.png" height="235" width="332"]]
209
Molly 2.1 210 == **CP2E Series Serial ** ==
211
212 Supported device:CP2E series,CP2E-N20DT-D
213
214 **HMI Settings**
215
216 |=**Items**|=**Settings**
217 |Protocol|OMRON CJ TCP FINS Ethemet
218 |Connection|Ethernet
219 |Port No.|9600
220 |Device No.|0
221 |HMI No.|0
222
223 **2.1 Create new HMI project**
224
225 Open PIStudio Software>>New Project, as shown in the figure below, set the touch screen project model and communication device type in sequence.
226
227 (% style="text-align:center" %)
228 [[image:1765960573514-689.png]]
229
230 ==== **2.2 Config HMI communication settings** ====
231
232 (1) Select the protocol as CJ UDP FINS Ethernet, then set the right PLC IP and corresponding port.
233
234 For example, in this case, PLC IP is 192.168.43.101.
235
236 (% style="text-align:center" %)
237 [[image:1765960573516-574.png]]
238
239
240 1. Set the HMI IP as the same segment with PLC side. For this case, it is 192.168.43.212.
241
242 (% style="text-align:center" %)
243 [[image:1765960573517-788.png]]
244
245 1. Program the HMI screen and put PLC address.
246
247
248
249 (% style="text-align:center" %)
250 [[image:1765960573518-279.png]]
251
252 **2.3 Config PLC communication settings**
253
254 (1) Using CX Programmer P9.72 or version above to connect the PLC. Click "PLC" on toolbar, select "auto online", select "CP1/CP2 built-in Ethernet online".
255
256 [[image:1765960573518-306.png]]
257
258
259 (2) Select "Direct connection" on the pop-up window. After connecting, it will prompt whether to upload the PLC program automatically, this can be selected as user need.
260
261 (% style="text-align:center" %)
262 [[image:1765960573519-579.png]]
263
264 (3) After the connected successfully, upload the configuration settings in "Settings" from the program tree on the right side.
265
266 (% style="text-align:center" %)
267 [[image:1765960573519-497.png||height="340" width="189"]]
268
269 1. After opening the Settings , select the option "transfer from PLC" to upload the configuration information from the PLC.
270
271 (% style="text-align:center" %)
272 [[image:1765960573520-894.png||height="566" width="526"]]
273
274 Figure 2-8
275
276 1. On the built-in Ethernet(Last one tab from Settings), will see the IP address, Node number and other related information. Node number need to configured as 101, Node number does not exist in the option of 0.
277
278 (% style="text-align:center" %)
279 [[image:1765960573520-855.png||height="554" width="515"]]
280
281 1. We will see the corresponding information available on the corresponding FINS/TCP and FINS/UDP settings.
282
283 (% style="text-align:center" %)
284 [[image:1765960573521-123.png]]
285
286 (% style="text-align:center" %)
287 [[image:1765960573521-815.png]]
288
289
290 **3.Notice**
291
292 (1) The number of Ethernet nodes of Omron CP2E PLC is not set as 0 but can only start from 1. If the number of nodes is 0, the IP settings of PLC may be invalid and cannot be pinged through PC command window;
293
294 (2) After config the parameters of Ethernet, it will take effect only after power off and restart;
295
296 (3) When multiple PLCs communicate simultaneously, try to ensure that the port numbers are not duplicated.
297
Wecon 1.1 298 == {{id name="HEC55Protocol"/}}**EC55 Protocol** ==
299
300 Supported device: EC55 temperature instrument
301
302 **1)HMI Settings**
303
304 |**Items**|**Settings**|**Note**
305 |Protocol|Omron EC55|
306 |Connection|RS485 (9600, 2, 7, EVEN)|
307 |Port No.|None|
308 |PLC station No.|0|
309
310 **2)Address List**
311
312 |**Type**|**Register**|**Device range**|**HMI range**|**Function**
313 |(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0
314 |C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0
315 |C3|0-CD(Hex)|0-205|Set Read/Write parameter for area 1
316 |(% rowspan="6" %)Word|80|0-13(Hex)|0-19|Set read only parameter in area 0
317 |81|0-4D(Hex)|0-77|Set Read/Write parameter in area 0
318 |83|0-CD(Hex)|0-205|Set Read/Write parameter in area 1
319 |CP|-|0-6|Read controller intrinsic property
320 |CS|-|0-2|Read controller states
321 |CA|-|0-17|Action command
322
323 **3)Device Settings**
324
325 Omron E5CC PLC configuration
326
327 After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting.
328
329 {{id name="I12.PLCProtocol_html_3d95e093792ba98a.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ca4d99a0d2ffe097.png||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]]
330
331 According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows
332
333 {{id name="I12.PLCProtocol_html_be583aa69dd6cf4c.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_984474debc119fab.png||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]]
334
335 **✎Note:** The communication settings for HMI should be consistent with this setting.
336
337 **Cable Wiring**
338
339 {{id name="I12.PLCProtocol_html_5e9a81a14106da9e.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_7b2556c42d43a768.png||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
340
341 {{id name="I12.PLCProtocol_html_1897d92be6948d58.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c6d16b5adff76549.png||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
342
343 **✎Note:**
344
345 * COM3 only available in PI8000/PI9000 series.
346 * CA address could not support continuous writing function;
347 * Because of CP address intrinsic property: read control intrinsic property, so please place the character input part in use. Set address with CP0 and character length 10, used to display controller type. And place a number input part, set address with CP5 (cache size). Do not place other CP type address without CP0 in screen, otherwise CP type address is invalid
348 * When set value into read & write address, it is necessary to switch the temperature instrument meter to the corresponding interface according to the menu of the instrument where the address locates, so that the value could be written, otherwise, the value could not be written; When the communication write setting of the instrument is turned off, the writing function is invalid. Writing function could be opened by using the 00 address of the CA register, which write 01 value.
349 * When continuous writing of a value to a read-write address, please make sure all continuous writing address could be written. Otherwise, if one of these addresses could not be written, then all continuous writing commands will fail.
350 * Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document.
351 * When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable.
352 * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
353 * {{id name="I12.PLCProtocol_html_d428cad280fdefb3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_f434f58797d3c0da.png||alt="12.PLC Protocol_html_d428cad280fdefb3.png" height="276" width="347"]] Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
354
355 == {{id name="HNXEtherNet2FIP"/}}**Ethernet/IP (NX/NJ Serirs)** ==
356
357 Supported series: Omron NX/NJ series
358
359 **HMI Setting**
360
361 |**Items**|**Settings**|**Note**
362 |Protocol|Omron NX/NJ Ethernet/IP|
363 |Connection|Ethernet|
364 |Port No.|44818|
365 |PLC station No.|1|
366
367 **Address list**
368
369 |=Data type|=Memo|=**Range**
370 |BOOL|1|FALSE(0) or TRUE(1)
371 |BYTE|8|0~~255
372 |WORD|16|0~~65535
373 |DWORD|32|0~~4294967295
374 |LWORD|64|0~~(2^64-1)
375 |SINT|8|-128~~127
376 |USINT|8|0~~255
377 |INT|16|-32768~~32767
378 |UINT|16|0~~65535
379 |DINT|32|-2147483648~~2147483647
380 |UDINT|32|0~~4294967295
381 |LINT|64|(-2^63)~~(2^63-1)
382 |ULINT|64|0~~(2^64-1)
383 |REAL|32|-3.402823466E+38~~3.402823466E+38
384 |LREAL|64|(((
385 -1.7976931348623158E+308~~1.79769313
386
387 48623158E+308
388 )))
389 |DATE|32|1970-01-01~~2106-02-07
390 |TIME|32|0D0H0M0S0MS~~49D17H2M47S295MS
391 |DATE_AND_TIME|32|1970-1-1-0:0:0~~2106-02-07-06:28:15
392 |TIME_OF_DAY|32|0:0:0~~23:59:59.999
393 |STRING| |
394
395 **Instruction**
396
397 1) In Sysmac Studio, please select [Publish Only] for [Network Publish] when setting address tag.
398
399 2) When [Do not publish] is selected for a tag, different import methods may lead to different results. When import tags by [Get Tags from Device], the tag will be eliminated. If [Import tags] is selected, the tags will be imported, but the communication will not succeed.
400
401 (% style="text-align:center" %)
402 [[image:1725933697098-418.png]]
403
404 **Export labels from Sysmac Studio**
405
406 Launch Sysmac Studio, under Global Variables create the address labels, and thenselect [Tools] -> [Export Global Variables];
407
408 (% style="text-align:center" %)
409 [[image:1725933727638-698.png]]
410
411 (% style="text-align:center" %)
412 [[image:1725933619328-454.png]]
413
414 Create a .CSV file,and Paste the [CX-Designer] into it.
415
416 (% class="box infomessage" %)
417 (((
418 **✎Note**: Make sure the CSV data is separated by commas.
419 )))
420
421 (% style="text-align:center" %)
422 [[image:1725933782144-300.png]]
423
424 Launch PIStudio, in [Communication] Settings add [Omron Ethernet/IP (NX/NJ Serirs)] protocol;
425
426 [[image:1725933826453-416.png]]
427
428 Click [Label manage];Click [Import Tags form file] and then Choose the .CSV file you need;
429
430 (% style="text-align:center" %)
431 [[image:1725933926323-707.png]]
432
433
434 **Communication Settings**
435
436 Set PLC IP in [Device IP] settings;
437
438 (% style="text-align:center" %)
439 [[image:1725934163105-489.png||height="99" width="241"]]
440
441
442 (% style="text-align:center" %)
443 [[image:1725934131262-239.png]]
444
445 **Cable Wiring**
446
447 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-4"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
448
449 == {{id name="HCV2FCJ1M2FCS1H"/}}**CJ2M Series Serial ** ==
450
451 **HMI Setting:**
452
453 |=**Parameters**|=**Recommended**
454 |=**PLC type**|OMRON CV/CJ1M/CS1H
455 |=**PLC I/F**|RS232/RS485
456 |=**Baud rate**|9600
457 |=**Data bits**|7
458 |=**Parity**|Even
459 |=**Stop bits**|2
460 |=**PLC sta. no.**|0
461
462 **PLC Setting:**
463
464 Open cx-programmer, create a new PLC project or open the project that has been created.
465 Create new project: [File]→[New]→[Device Type]CJ2M→[settings]→[General]→[CPU Type]CPU31→[OK]→[OK].
466
467 {{id name="I1.265B05EFA5DE57A0B.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1edc9bf9e8c98170.png||alt="1.2 新建工程.png" height="660" width="1134"]]
468
469 PLC Default Parameters:[Settings]→[Serial Port]→[Communication Settings]→[Standard]9600,1,7,2,E means:[Baud rate] 9600, [Data bits]7, [Stop bits] 2,[Parity] EVEN→[Unit Number]0 →[Mode]Host Link.
470 Note:The serial port parameters should be set depending on field requirements
471
472 {{id name="I1.34E3253E353C26570914D7F6E.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d4a08b7e4dfac0bd.png||alt="1.3串口参数配置.png" height="660" width="1134"]]
473
474 **Device Address:**
475
476 |=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
477 |=B|CIO|DDDDDdd|0 ~~65535.15|I/O and Internal Relay
478 |=B|W|DDDDDdd|0 ~~65535.15|Hold Relay
479 |=B|D|DDDDDdd|0 ~~65535.15|Link Relay
480 |=B|H|DDDDDdd|0 ~~65535.15|
481 |=B|A|DDDDDdd|0 ~~65535.15|
482 |=B|TF|DDDDD|0 ~~ 99999|
483 |=B|CF|DDDDD|0 ~~ 99999|Auxiliary Relay
484 |=B|T|DDDDDdd|0 ~~65535.15|
485 |=B|C|DDDDDdd|0 ~~65535.15|
486 |=B|EM0|DDDDDdd|0 ~~ 99999.15|
487 |=B|EM1|DDDDDdd|0 ~~ 99999.15|
488 |=B|EM2|DDDDDdd|0 ~~ 99999.15|
489 |=B|EM3|DDDDDdd|0 ~~ 99999.15|
490 |=B|EM4|DDDDDdd|0 ~~ 99999.15|
491 |=B|EM5|DDDDDdd|0 ~~ 99999.15|
492 |=B|EM6|DDDDDdd|0 ~~ 99999.15|
493 |=B|EM7|DDDDDdd|0 ~~ 99999.15|
494 |=B|EM8|DDDDDdd|0 ~~ 99999.15|
495 |=B|EM9|DDDDDdd|0 ~~ 99999.15|
496 |=B|EMA|DDDDDdd|0 ~~ 99999.15|
497 |=B|EMB|DDDDDdd|0 ~~ 99999.15|
498 |=B|EMC|DDDDDdd|0 ~~ 99999.15|
499 |=B|Lamp|D|0~~0|
500
501 |=**Bit/Word**|=**Device type**|=**Format**|=**Range**
502 |=W|W|DDDDD|0 ~~ 99999
503 |=W|D|DDDDD|0 ~~ 99999
504 |=W|H|DDDDD|0 ~~ 99999
505 |=W|A|DDDDD|0 ~~ 99999
506 |=W|T|DDDDD|0 ~~ 99999
507 |=W|C|DDDDD|0 ~~ 99999
508 |=W|CIO|DDDDD|0 ~~ 99999
509 |=W|EM0|DDDDD|0 ~~ 99999
510 |=W|EM1|DDDDD|0 ~~ 99999
511 |=W|EM2|DDDDD|0 ~~ 99999
512 |=W|EM3|DDDDD|0 ~~ 99999
513 |=W|EM4|DDDDD|0 ~~ 99999
514 |=W|EM5|DDDDD|0 ~~ 99999
515 |=W|EM6|DDDDD|0 ~~ 99999
516 |=W|EM7|DDDDD|0 ~~ 99999
517 |=W|EM8|DDDDD|0 ~~ 99999
518 |=W|EM9|DDDDD|0 ~~ 99999
519 |=W|EMA|DDDDD|0 ~~ 99999
520 |=W|EMB|DDDDD|0 ~~ 99999
521 |=W|EMC|DDDDD|0 ~~ 99999
522 |=W|IR|DDDDD|0 ~~ 99999
523 |=W|DR|DDDDD|0 ~~ 99999
524
525 **Wiring Diagram:**
526
527 **RS-485**
528
529 {{id name="I3.1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a94192ee427e053b.png||alt="3.1.png" height="186" width="546"]]
530
531 Pin Definition Diagram
532
533 {{id name="I3.2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4da7b3277467c9a6.png||alt="3.2.png" height="408" width="593"]]
534
535 **RS-232**
536
537 CPU Port (CPM2A,CQM1/1H,C200H/HS/ALPHA series)
538
539 Communication Module:
540
541 CPM1-CIF01 adapter (for CPM1/CPM1A/CPM2A series, CQM1/CQM1H series) CPM1H-SCB41 communication module (for CQM1H-CPU51/61)
542
543 The serial port pin assignments may vary between HMI models, please click the following link for more information.
544
545 {{id name="Iimage-20220914115848-1.jpeg"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_138658736ae39b8.jpg||alt="image-20220914115848-1.jpeg" height="499" width="610"]]
546
547 == C200HE Series Serial ==
548
549 Supported series: Omron C200HE series
550
551 **HMI Settings(recommended)**
552
553 |=Item|=Recommended
554 |=Protocol|OMRON HOSTLINK
555 |=Connection|RS232
556 |=Baud rate|9600
557 |=Stop bits|2
558 |=Data bits|7
559 |=Parity|EVEN
560 |=PLC Station No.|0
561 |=HMI Station No.|0
562
563 **Address List**
564
565 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**
566 |Bit|IR|IR|IR d|0~~99999
567 |Bit|LR|LR|LR d|0~~99999
568 |Bit|HR|HR|HR d|0~~99999
569 |Bit|AR|AR|AR d|0~~99999
570 |Bit|TIMB|TIMB|TIMB d|0~~99999
571 |Bit|CNTB|CNTB|CNTB d|0~~99999
572 |Bit|TIM|TIM|TIM d|0~~99999
573 |Bit|DM|DM|DM d|0~~99999
574 |Bit|CNT|CNT|CNT d|0~~99999
575 |Bit|WR|WR|WR d|0~~99999
576 |Bit|LAMP|LAMP|LAMP d|0~~0
577 |Word|IR|IR|IR d|0~~99999
578 |Word|LR|LR|LR d|0~~99999
579 |Word|HR|HR|HR d|0~~99999
580 |Word|AR|AR|AR d|0~~99999
581 |Word|TIM|TIM|TIM d|0~~99999
582 |Word|DM|DM|DM d|0~~99999
583 |Word|CNT|CNT|CNT d|0~~99999
584 |Word|WR|WR|WR d|0~~99999
585