Wiki source code of Omron

Version 48.1 by Jett on 2024/09/10 10:28

Hide last authors
Hunter 2.1 1 = {{id name="HOmron"/}}**Omron** =
2
Devin Chen 40.1 3 == **CJ2M Series Ethemet** ==
Hunter 2.1 4
Devin Chen 31.1 5 Supported device:CJ series, CJ1W-EIP21,CJ2M-EIP21
Hunter 2.1 6
7 **HMI Settings**
8
Devin Chen 31.1 9 |=**Items**|=**Settings**
10 |Protocol|OMRON CJ TCP FINS Ethemet
11 |Connection|Ethernet
12 |Port No.|9600
13 |Device No.|0
14 |HMI No.|0
Hunter 2.1 15
Devin Chen 37.1 16 (% id="cke_bm_1048S" style="display:none" %)** **
Devin Chen 32.1 17
Devin Chen 37.1 18 **Address List**
Devin Chen 32.1 19
Hunter 2.1 20 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
Devin Chen 35.1 21 |(% colspan="1" rowspan="23" %)Bit|CIO|CIO|CIO d|0~~99999|
22 |W|W|W d|0~~99999|
23 |D|D|D d|0~~99999|
24 |H|H|H d|0~~99999|
25 |A|A|A d|0~~99999|
26 |T|T|T h|0~~99999|
27 |CF|CF|CF d|0~~99999|
28 |FF|FF|FF d|0~~99999|
29 |C|C|C d|0~~99999|
30 |EM0|EM0|EM0 d|0~~99999|
31 |EM1|EM1|EM1 d|0~~99999|
32 |EM2|EM2|EM2 d|0~~99999|
33 |EM3|EM3|EM3 d|0~~99999|
34 |EM4|EM4|EM4 d|0~~99999|
35 |EM5|EM5|EM5 h|0~~99999|
36 |EM6|EM6|EM6 d|0~~99999|
37 |EM7|EM7|EM7 d|0~~99999|
38 |EM8|EM8|EM8 d|0~~99999|
39 |EM9|EM9|EM9 d|0~~99999|
40 |EMA|EMA|EMA d|0~~99999|
41 |EMB|EMB|EMB d|0~~99999|
42 |EMC|EMC|EMC d|0~~99999|
43 |Lamp|Lamp|Lamp d|0~~0|
44 |(% colspan="1" rowspan="24" %)Word|CIO|CIO|CIO d|0~~99999|
45 |W|W|W d|0~~99999|
46 |D|D|D d|0~~99999|
47 |H|H|H d|0~~99999|
48 |A|A|A d|0~~99999|
49 |T|T|T h|0~~99999|
50 |CF|CF|CF d|0~~99999|
51 |FF|FF|FF d|0~~99999|
52 |C|C|C d|0~~99999|
53 |EM0|EM0|EM0 d|0~~99999|
54 |EM1|EM1|EM1 d|0~~99999|
55 |EM2|EM2|EM2 d|0~~99999|
56 |EM3|EM3|EM3 d|0~~99999|
57 |EM4|EM4|EM4 d|0~~99999|
58 |EM5|EM5|EM5 h|0~~99999|
59 |EM6|EM6|EM6 d|0~~99999|
60 |EM7|EM7|EM7 d|0~~99999|
61 |EM8|EM8|EM8 d|0~~99999|
62 |EM9|EM9|EM9 d|0~~99999|
63 |EMA|EMA|EMA d|0~~99999|
64 |EMB|EMB|EMB d|0~~99999|
65 |EMC|EMC|EMC d|0~~99999|
66 |IR|IR|IR d|0~~99999|
67 |DR|DR|DR d|0~~99999|
Hunter 2.1 68
Devin Chen 37.1 69 **Configure the communication protocol**
70
71 {{id name="Iimage-20220830143348-1.png"/}}
72
73 (% style="text-align:center" %)
74 [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_95df6576665b7885.png||alt="image-20220830143348-1.png" height="735" width="616"]]
75
76 {{id name="Iimage-20220830143511-2.png"/}}
77
78 (% style="text-align:center" %)
79 [[image:2.3.2.png]]
80
81 **PLC Setting:**
82
83 ①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
84 Note:The IP address of the PLC is displayed on the LED when the PLC is powered up
85
86 (% style="text-align:center" %)
87 [[image:1.3.1.png]]
88
89 ②[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
90
91 (% style="text-align:center" %)
92 [[image:1.3.2.png]]
93
94 ③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
95
96 [IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0.
97 Note: Please configure the IP parameters of PLC according to the field needs
98
99 (% style="text-align:center" %)
100 [[image:1.4.png]]
101
102 ④Two rotary coding switches should be set depanding on the program paremeter:
103 a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0
104
105 (% style="text-align:center" %)
106 [[image:WeCom Screenshot_20230828090604.png]]
107
108
109 **b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.**
110
111
112 (% style="text-align:center" %)
113 [[image:WeCom.png]]
114
Hunter 2.1 115 **Cable Wiring**
116
117 Pin Definition Diagram
118
Devin Chen 31.1 119 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-3"/}}
Hunter 2.1 120
Devin Chen 31.1 121 (% style="text-align:center" %)
122 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
123
Devin Chen 41.1 124 == {{id name="HCS128CP1E2FCP1H29"/}}**CP1E Series Serial ** ==
Hunter 2.1 125
126 Supported device: OMRON CS1(CP1E/CP1H)
127
128 **HMI Settings**
129
130 |=**Items**|=**Settings**|=**Note**
131 |Protocol|OMRON CS1(CP1E/CP1H)|
132 |Connection|RS232 (9600, 2, 7, EVEN)|
133 |Port No.|None|
134 |PLC station No.|0|
135
136 **Address List**
137
138 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
Devin Chen 36.1 139 |(% colspan="1" rowspan="22" %)Bit|CIO|CIO|CIO d|0~~99999|
140 |W|W|W d|0~~99999|
141 |D|D|D d|0~~99999|
142 |H|H|H d|0~~99999|
143 |A|A|A d|0~~99999|
144 |TF|T|T h|0~~99999|
145 |CF|CF|CF d|0~~99999|
146 |T|FF|FF d|0~~99999|
147 |C|C|C d|0~~99999|
148 |EM0|EM0|EM0 d|0~~99999|
149 |EM1|EM1|EM1 d|0~~99999|
150 |EM2|EM2|EM2 d|0~~99999|
151 |EM3|EM3|EM3 d|0~~99999|
152 |EM4|EM4|EM4 d|0~~99999|
153 |EM5|EM5|EM5 h|0~~99999|
154 |EM6|EM6|EM6 d|0~~99999|
155 |EM7|EM7|EM7 d|0~~99999|
156 |EM8|EM8|EM8 d|0~~99999|
157 |EM9|EM9|EM9 d|0~~99999|
158 |EMA|EMA|EMA d|0~~99999|
159 |EMB|EMB|EMB d|0~~99999|
160 |EMC|EMC|EMC d|0~~99999|
161 |(% colspan="1" rowspan="23" %)Word|CIO|CIO|CIO d|0~~99999|
162 |W|W|W d|0~~99999|
163 |D|D|D d|0~~99999|
164 |H|H|H d|0~~99999|
165 |A|A|A d|0~~99999|
166 |T|T|T h|0~~99999|
167 |CIO|CF|CF d|0~~99999|
168 |C|C|C d|0~~99999|
169 |EM0|EM0|EM0 d|0~~99999|
170 |EM1|EM1|EM1 d|0~~99999|
171 |EM2|EM2|EM2 d|0~~99999|
172 |EM3|EM3|EM3 d|0~~99999|
173 |EM4|EM4|EM4 d|0~~99999|
174 |EM5|EM5|EM5 h|0~~99999|
175 |EM6|EM6|EM6 d|0~~99999|
176 |EM7|EM7|EM7 d|0~~99999|
177 |EM8|EM8|EM8 d|0~~99999|
178 |EM9|EM9|EM9 d|0~~99999|
179 |EMA|EMA|EMA d|0~~99999|
180 |EMB|EMB|EMB d|0~~99999|
181 |EMC|EMC|EMC d|0~~99999|
182 |IR|IR|IR d|0~~99999|
183 |DR|DR|DR d|0~~99999|
Hunter 2.1 184
185 **Configure the communication protocol**
186
187 {{id name="Iimage-20220902153118-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4acef6476c6f9de3.png||alt="image-20220902153118-1.png" height="735" width="616"]]
188
189 {{id name="Iimage-20220902151322-2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4f9620139b8a44b3.png||alt="image-20220902151322-2.png" height="905" width="1038"]]
190
Devin Chen 31.1 191 **{{id name="cke_bm_27437S"/}} PLC Settings(CX-Programmer)**
Hunter 2.1 192
193 Open cx-programmer, create a new PLC project or open the project that has been created.
194 Create new project: [File]→[New]→[Device Type]CP1E→[settings]→[General]→[CPU Type]N30→[OK]→[OK].
195
196 {{id name="I1.25DE57A0B65B05EFAD.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_aa70463d933c7549.png||alt="1.2 工程新建D.png" height="660" width="1134"]]
197
198 PLC Default Parameters:[Settings]→[Built-in RS232C Port]→[Communication Settings]→[Standard]9600,1,7,2,E means:[Baud rate] 9600, [Data bits]7, [Stop bits] 2,[Parity] EVEN→[Unit Number]0 →[Mode]Host Link(Defaut).
199
200 {{id name="I1.34E3253E353C26570768467E5770B-914D7F6ED.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_84484fbbb00ca61.png||alt="1.3 串口参数的查看-配置D.png" height="660" width="1134"]]
201
202 **Cable Wiring**
203
204 {{id name="I56FE72473.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4c5480a409965d39.png||alt="image-20220902153949-2.png" height="508" width="2014"]]
205
206 Pin Definition Diagram
207
208 {{id name="I3.1.263A553E3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ad6138e6812c2253.png||alt="image-20220902154056-3.png" height="235" width="332"]]
209
210 == {{id name="HEC55Protocol"/}}**EC55 Protocol** ==
211
212 Supported device: EC55 temperature instrument
213
214 **1)HMI Settings**
215
216 |**Items**|**Settings**|**Note**
217 |Protocol|Omron EC55|
218 |Connection|RS485 (9600, 2, 7, EVEN)|
219 |Port No.|None|
220 |PLC station No.|0|
221
222 **2)Address List**
223
224 |**Type**|**Register**|**Device range**|**HMI range**|**Function**
225 |(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0
226 |C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0
227 |C3|0-CD(Hex)|0-205|Set Read/Write parameter for area 1
228 |(% rowspan="6" %)Word|80|0-13(Hex)|0-19|Set read only parameter in area 0
229 |81|0-4D(Hex)|0-77|Set Read/Write parameter in area 0
230 |83|0-CD(Hex)|0-205|Set Read/Write parameter in area 1
231 |CP|-|0-6|Read controller intrinsic property
232 |CS|-|0-2|Read controller states
233 |CA|-|0-17|Action command
234
235 **3)Device Settings**
236
237 Omron E5CC PLC configuration
238
239 After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting.
240
241 {{id name="I12.PLCProtocol_html_3d95e093792ba98a.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ca4d99a0d2ffe097.png||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]]
242
243 According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows
244
245 {{id name="I12.PLCProtocol_html_be583aa69dd6cf4c.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_984474debc119fab.png||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]]
246
247 **✎Note:** The communication settings for HMI should be consistent with this setting.
248
249 **Cable Wiring**
250
251 {{id name="I12.PLCProtocol_html_5e9a81a14106da9e.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_7b2556c42d43a768.png||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
252
253 {{id name="I12.PLCProtocol_html_1897d92be6948d58.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c6d16b5adff76549.png||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
254
255 **✎Note:**
256
257 * COM3 only available in PI8000/PI9000 series.
258 * CA address could not support continuous writing function;
259 * Because of CP address intrinsic property: read control intrinsic property, so please place the character input part in use. Set address with CP0 and character length 10, used to display controller type. And place a number input part, set address with CP5 (cache size). Do not place other CP type address without CP0 in screen, otherwise CP type address is invalid
260 * When set value into read & write address, it is necessary to switch the temperature instrument meter to the corresponding interface according to the menu of the instrument where the address locates, so that the value could be written, otherwise, the value could not be written; When the communication write setting of the instrument is turned off, the writing function is invalid. Writing function could be opened by using the 00 address of the CA register, which write 01 value.
261 * When continuous writing of a value to a read-write address, please make sure all continuous writing address could be written. Otherwise, if one of these addresses could not be written, then all continuous writing commands will fail.
262 * Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document.
263 * When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable.
264 * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
265 * {{id name="I12.PLCProtocol_html_d428cad280fdefb3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_f434f58797d3c0da.png||alt="12.PLC Protocol_html_d428cad280fdefb3.png" height="276" width="347"]] Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
266
Jett 46.1 267 == {{id name="HNXEtherNet2FIP"/}}**Ethernet/IP (NX/NJ Serirs)** ==
Hunter 2.1 268
269 Supported series: Omron NX/NJ series
270
271 **HMI Setting**
272
273 |**Items**|**Settings**|**Note**
274 |Protocol|Omron NX Ethernet/IP|
275 |Connection|Ethernet|
276 |Port No.|44818|
277 |PLC station No.|1|
278
Jett 46.1 279 **Address list**
280
281 |Data type|Data format in PIStudio|Memo
282 |BOOL|bit|
283 |Byte|16-bit BCD,HEX,Binary,Unsigned|8-bit
284 |SInt|16-bit BCD,HEX,Binary,Signed|8-bit
285 |USInt|16-bit BCD,HEX,Binary,Unsigned|8-bit
286 |Word|16-bit BCD,HEX,Binary,Unsigned|16-bit
287 |Int|16-bit BCD,HEX,Binary,Signed|16-bit
288 |UInt|16-bit BCD,HEX,Binary,Unsigned|16-bit
289 |DWord|32-bit BCD, Hex, Binary, Unsigned|32-bit
290 |DInt|32-bit BCD, Hex, Binary, Signed|32-bit
291 |Real|32-bit Float|32-bit
292 |UDInt|32-bit BCD, Hex, Binary, Unsigned|32-bit
293 |LInt|64-bit Signed|64-bit
294 |ULInt|64-bit USigned|64-bit
295 |LWord|64-bit USigned|64-bit
Jett 47.1 296 |LReal|64-bit Float|64-bit
Jett 46.1 297
Hunter 2.1 298 **Instruction**
299
300 1) In Sysmac Studio, please select [Publish Only] for [Network Publish] when setting address tag.
301
302 2) When [Do not publish] is selected for a tag, different import methods may lead to different results. When import tags by [Get Tags from Device], the tag will be eliminated. If [Import tags] is selected, the tags will be imported, but the communication will not succeed.
303
Jett 45.1 304 (% style="text-align:center" %)
305 [[image:1725933697098-418.png]]
Hunter 2.1 306
307 **Export labels from Sysmac Studio**
308
309 Launch Sysmac Studio, under Global Variables create the address labels, and thenselect [Tools] -> [Export Global Variables];
310
Jett 45.1 311 (% style="text-align:center" %)
312 [[image:1725933727638-698.png]]
Hunter 2.1 313
Jett 48.1 314 (% style="text-align:center" %)
Jett 45.1 315 [[image:1725933619328-454.png]]
Hunter 2.1 316
Jett 45.1 317 Create a .CSV file,and Paste the [CX-Designer] into it.
Hunter 2.1 318
Jett 45.1 319 (% style="text-align:center" %)
320 [[image:1725933782144-300.png]]
Hunter 2.1 321
Jett 45.1 322 Launch PIStudio, in [Communication] Settings add [Omron Ethernet/IP (NX/NJ Serirs)] protocol;
Hunter 2.1 323
Jett 45.1 324 [[image:1725933826453-416.png]]
Hunter 2.1 325
Jett 45.1 326 Click [Label manage];Click [Import Tags form file] and then Choose the .CSV file you need;
Hunter 2.1 327
Jett 45.1 328 (% style="text-align:center" %)
329 [[image:1725933926323-707.png]]
Hunter 2.1 330
Jett 45.1 331
Hunter 2.1 332 **Communication Settings**
333
Jett 45.1 334 Set PLC IP in [Device IP] settings;
Hunter 2.1 335
Jett 45.1 336 (% style="text-align:center" %)
337 [[image:1725934163105-489.png||height="99" width="241"]]
Hunter 2.1 338
339
Jett 45.1 340 (% style="text-align:center" %)
341 [[image:1725934131262-239.png]]
Hunter 2.1 342
343 **Cable Wiring**
344
345 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-4"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
346
Devin Chen 39.1 347 == {{id name="HCV2FCJ1M2FCS1H"/}}**CJ2M Series Serial ** ==
Hunter 2.1 348
349 **HMI Setting:**
350
351 |=**Parameters**|=**Recommended**
352 |=**PLC type**|OMRON CV/CJ1M/CS1H
353 |=**PLC I/F**|RS232/RS485
354 |=**Baud rate**|9600
355 |=**Data bits**|7
356 |=**Parity**|Even
357 |=**Stop bits**|2
358 |=**PLC sta. no.**|0
359
360 **PLC Setting:**
361
362 Open cx-programmer, create a new PLC project or open the project that has been created.
363 Create new project: [File]→[New]→[Device Type]CJ2M→[settings]→[General]→[CPU Type]CPU31→[OK]→[OK].
364
365 {{id name="I1.265B05EFA5DE57A0B.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1edc9bf9e8c98170.png||alt="1.2 新建工程.png" height="660" width="1134"]]
366
367 PLC Default Parameters:[Settings]→[Serial Port]→[Communication Settings]→[Standard]9600,1,7,2,E means:[Baud rate] 9600, [Data bits]7, [Stop bits] 2,[Parity] EVEN→[Unit Number]0 →[Mode]Host Link.
368 Note:The serial port parameters should be set depending on field requirements
369
370 {{id name="I1.34E3253E353C26570914D7F6E.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d4a08b7e4dfac0bd.png||alt="1.3串口参数配置.png" height="660" width="1134"]]
371
372 **Device Address:**
373
374 |=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
375 |=B|CIO|DDDDDdd|0 ~~65535.15|I/O and Internal Relay
376 |=B|W|DDDDDdd|0 ~~65535.15|Hold Relay
377 |=B|D|DDDDDdd|0 ~~65535.15|Link Relay
378 |=B|H|DDDDDdd|0 ~~65535.15|
379 |=B|A|DDDDDdd|0 ~~65535.15|
380 |=B|TF|DDDDD|0 ~~ 99999|
381 |=B|CF|DDDDD|0 ~~ 99999|Auxiliary Relay
382 |=B|T|DDDDDdd|0 ~~65535.15|
383 |=B|C|DDDDDdd|0 ~~65535.15|
384 |=B|EM0|DDDDDdd|0 ~~ 99999.15|
385 |=B|EM1|DDDDDdd|0 ~~ 99999.15|
386 |=B|EM2|DDDDDdd|0 ~~ 99999.15|
387 |=B|EM3|DDDDDdd|0 ~~ 99999.15|
388 |=B|EM4|DDDDDdd|0 ~~ 99999.15|
389 |=B|EM5|DDDDDdd|0 ~~ 99999.15|
390 |=B|EM6|DDDDDdd|0 ~~ 99999.15|
391 |=B|EM7|DDDDDdd|0 ~~ 99999.15|
392 |=B|EM8|DDDDDdd|0 ~~ 99999.15|
393 |=B|EM9|DDDDDdd|0 ~~ 99999.15|
394 |=B|EMA|DDDDDdd|0 ~~ 99999.15|
395 |=B|EMB|DDDDDdd|0 ~~ 99999.15|
396 |=B|EMC|DDDDDdd|0 ~~ 99999.15|
397 |=B|Lamp|D|0~~0|
398
399 |=**Bit/Word**|=**Device type**|=**Format**|=**Range**
400 |=W|W|DDDDD|0 ~~ 99999
401 |=W|D|DDDDD|0 ~~ 99999
402 |=W|H|DDDDD|0 ~~ 99999
403 |=W|A|DDDDD|0 ~~ 99999
404 |=W|T|DDDDD|0 ~~ 99999
405 |=W|C|DDDDD|0 ~~ 99999
406 |=W|CIO|DDDDD|0 ~~ 99999
407 |=W|EM0|DDDDD|0 ~~ 99999
408 |=W|EM1|DDDDD|0 ~~ 99999
409 |=W|EM2|DDDDD|0 ~~ 99999
410 |=W|EM3|DDDDD|0 ~~ 99999
411 |=W|EM4|DDDDD|0 ~~ 99999
412 |=W|EM5|DDDDD|0 ~~ 99999
413 |=W|EM6|DDDDD|0 ~~ 99999
414 |=W|EM7|DDDDD|0 ~~ 99999
415 |=W|EM8|DDDDD|0 ~~ 99999
416 |=W|EM9|DDDDD|0 ~~ 99999
417 |=W|EMA|DDDDD|0 ~~ 99999
418 |=W|EMB|DDDDD|0 ~~ 99999
419 |=W|EMC|DDDDD|0 ~~ 99999
420 |=W|IR|DDDDD|0 ~~ 99999
421 |=W|DR|DDDDD|0 ~~ 99999
422
423 **Wiring Diagram:**
424
425 **RS-485**
426
427 {{id name="I3.1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a94192ee427e053b.png||alt="3.1.png" height="186" width="546"]]
428
429 Pin Definition Diagram
430
431 {{id name="I3.2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4da7b3277467c9a6.png||alt="3.2.png" height="408" width="593"]]
432
433 **RS-232**
434
435 CPU Port (CPM2A,CQM1/1H,C200H/HS/ALPHA series)
436
437 Communication Module:
438
439 CPM1-CIF01 adapter (for CPM1/CPM1A/CPM2A series, CQM1/CQM1H series) CPM1H-SCB41 communication module (for CQM1H-CPU51/61)
440
441 The serial port pin assignments may vary between HMI models, please click the following link for more information.
442
443 {{id name="Iimage-20220914115848-1.jpeg"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_138658736ae39b8.jpg||alt="image-20220914115848-1.jpeg" height="499" width="610"]]
444
Hunter 43.1 445 == C200HE Series Serial ==
Hunter 2.1 446
447 Supported series: Omron C200HE series
448
449 **HMI Settings(recommended)**
450
451 |=Item|=Recommended
452 |=Protocol|OMRON HOSTLINK
453 |=Connection|RS232
454 |=Baud rate|9600
455 |=Stop bits|2
456 |=Data bits|7
457 |=Parity|EVEN
458 |=PLC Station No.|0
459 |=HMI Station No.|0
460
461 **Address List**
462
463 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**
464 |Bit|IR|IR|IR d|0~~99999
465 |Bit|LR|LR|LR d|0~~99999
466 |Bit|HR|HR|HR d|0~~99999
467 |Bit|AR|AR|AR d|0~~99999
468 |Bit|TIMB|TIMB|TIMB d|0~~99999
469 |Bit|CNTB|CNTB|CNTB d|0~~99999
470 |Bit|TIM|TIM|TIM d|0~~99999
471 |Bit|DM|DM|DM d|0~~99999
472 |Bit|CNT|CNT|CNT d|0~~99999
473 |Bit|WR|WR|WR d|0~~99999
474 |Bit|LAMP|LAMP|LAMP d|0~~0
475 |Word|IR|IR|IR d|0~~99999
476 |Word|LR|LR|LR d|0~~99999
477 |Word|HR|HR|HR d|0~~99999
478 |Word|AR|AR|AR d|0~~99999
479 |Word|TIM|TIM|TIM d|0~~99999
480 |Word|DM|DM|DM d|0~~99999
481 |Word|CNT|CNT|CNT d|0~~99999
482 |Word|WR|WR|WR d|0~~99999
483
484 **Cable Wiring**
485
486 {{id name="I3.1.263A553E3.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ad6138e6812c2253.png||alt="3.1.2 接口.png" height="240" width="339"]]