FP Series Serial
1)HMI Settings
| Item | Settings | Note |
| Protocol | Panasonic FP MEWTOCOL | |
| Connection | RS232 | |
| Baud rate | 9600 | |
| Data bit | 8 | |
| Parity | ODD | |
| Stop bit | 1 | |
| PLC station No. | 1 |
2)Address List
| Type | Device registers | Format | Range | Note |
| Bit | X | X d | 0~9999 | |
| Bit | Y | Y d | 0~9999 | |
| Bit | R | R d | 0~9999 | |
| Bit | T | T d | 0~9999 | |
| Bit | C | C d | 0~9999 | |
| Bit | L | L d | 0~9999 | |
| Word | WX | WX d | 0~9999 | |
| Word | WY | WY d | 0~9999 | |
| Word | WR | WR d | 0~9999 | |
| Word | WL | WL d | 0~9999 | |
| Word | LD | LD d | 0~9999 | |
| Word | DT | DT d | 0~65535 | |
| Word | FL | FL d | 0~9999 | |
| Word | EV | EV d | 0~9999 | |
| Word | SV | SV d | 0~9999 |
3)Configure the communication protocol


5)PLC Setting:
①PLC Default Parameters:
1.[Option]→[System register settings]→[COM0 Port]→[Unit No.]1→[Communication Mode]Computer Link → [Baud Rate]9600bps → [Communication Format]char.bit:8bits;Parity:Odd;Stop Bit:1→[OK].

②[Online]→[Communication Settings]→[Port to use]COM(USB)→[Port to use (No.)]PIDSX PLC USB-COM(COM12)→[Communications condition settings] Communications speed:9600bps;Data
length:8bits;Stop bits:1bit;Parity:Odd;Timeout (sec):5→[Automatic search items in communications conditions]:check the option[Communications speed],[ Data length],[ Parity]→[OK]
Please select according to the actual connection between PC and PLC.

5)Cable Wiring
Figure

Pin Definition Diagram


FP Series Ethernet
HMI Settings
| Item | Settings | Note |
| Protocol | Panasonic FP MEWTOCOL(Ethernet) | |
| Connection | Ethernet | |
| Port No. | 32769 | |
| Network | TCP_Client_2N | |
| PLC station No. | 1 |
Address List
| Type | Device registers | Format | Range | Note |
| Bit | X | X d | 0~9999 | |
| Bit | Y | Y d | 0~9999 | |
| Bit | R | R d | 0~9999 | |
| Bit | T | T d | 0~9999 | |
| Bit | C | C d | 0~9999 | |
| Bit | L | L d | 0~9999 | |
| Word | WX | WX d | 0~9999 | |
| Word | WY | WY d | 0~9999 | |
| Word | WR | WR d | 0~9999 | |
| Word | WL | WL d | 0~9999 | |
| Word | LD | LD d | 0~9999 | |
| Word | DT | DT d | 0~65535 | |
| Word | FL | FL d | 0~9999 | |
| Word | EV | EV d | 0~9999 | |
| Word | SV | SV d | 0~9999 |
Configure the communication protocol


PLC Setting:
1.[Option]→[Ethernet settings]→[Basic communications information]→[IPv4 address autonatic acquisition]No → [Home IP address]192.168.40.11 → [Subnet mask]255.255.255.0 → [Default gateway]192.168.40.1

2.[ System connecton settings] →[Home port nunber]32769→[OK].

Note: Please configure the IP parameters of PLC according to the field needs
Cable Wiring

Pin Definition Diagram