... ... @@ -250,4 +250,118 @@
250 250  
251 251  == **Ethernet/IP DF1** ==
252 252  
253 -
253 +Supported Series: Rockwell MicroLogix 1100, 1400, SLC5/05 Ethernet port. MicroLogix1000,1200,1500,SLC 5/03, 5/04 with 1761-NET-ENI
254 +
255 +|**Items**|**Settings**|**Note**
256 +|Protocol|Rockwell Ethernet/IP DF1|
257 +|Connection|Ethernet|
258 +|Port No.|44818|
259 +|PLC station No.|1|
260 +
261 +**Address List**
262 +
263 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note
264 +|(% rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1
265 +|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0
266 +|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2
267 +|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3
268 +|BN|BNddddd.dd|0.0~~99255.15|(((
269 +Bit data file B0~~B99
270 +
271 +First two digits is for file number
272 +
273 +For example, BN13001.00 represents file number B13, address 001, the 0th bit.
274 +)))
275 +|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7
276 +|NN|NNddddd.dd|0.0~~99255.15|(((
277 +Integer data file bit format N0~~N99
278 +
279 +First two digits is for file number
280 +
281 +For example, NN13001.00 represents file number N13, address 001, the 0th bit.
282 +)))
283 +|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2
284 +|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value)
285 +|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value)
286 +|TNS|TNSddddd|0~~99255|(((
287 +Timer Preset Value
288 +
289 +First two digits is for file number
290 +
291 +For example, TNS99255 represents file number T99, address 255.
292 +)))
293 +|TNP|TNPddddd|0~~99255|(((
294 +Timer Accumulator Value
295 +
296 +First two digits is for file number
297 +
298 +For example, TNP99255 represents file number T99, address 255.
299 +)))
300 +|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value)
301 +|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value)
302 +|CNS|CNSddddd|0~~99255|(((
303 +Counter Preset Value
304 +
305 +First two digits is for file number
306 +
307 +For example, CNS99255 represents file number C99, address 255.
308 +)))
309 +|CNP|CNPddddd|0~~99255|(((
310 +Counter Accumulator Value
311 +
312 +First two digits is for file number
313 +
314 +For example, CNP99255 represents file number C99, address 255.
315 +)))
316 +|N7|N7ddd|0~~255|Only able to communicate with file number N7
317 +|NN|NNddd|0~~99255|(((
318 +Integer data file
319 +
320 +First two digits is for file number
321 +
322 +For example, NN99255 represents file number N99, address 255.
323 +)))
324 +|(% rowspan="3" %)Double Word|F8|F8ddd|0~~255|Only able to communicate with file number F8
325 +|FN|FNddddd|0~~99255|(((
326 +Floating point data file
327 +
328 +First two digits is for file number
329 +
330 +For example, FN99255 represents file number F99, address 255.
331 +)))
332 +|LN|LNddddd|0~~99255|Long
333 +
334 +**PLC Setting:**
335 +
336 +1.Open the RSLinx Classic Lite software and click [Configure Drivers...] in [Communications].[[image:1.png]]
337 +
338 +2.Click the drop-down menu and select EtherNet/IP driver[[image:2.png]]
339 +
340 +3.Click Add New and a pop-up window will pop up. Name the driver and click [OK] in the pop-up window.[[image:3.png]]
341 +
342 +4.The configuration driver window pops up., click on the correct network adapter option (such as the ASIX USB to Fast Ethernet Family Adapter option in this picture), and click OK
343 +
344 +[[image:4.png]]
345 +
346 +5.Click the [Close] button.[[image:5.png]]
347 +
348 +6.Click the [RSWho] button.[[image:6.png]]
349 +
350 +7.Pop up the RS Who window, indicating that the driver has been added successfully.[[image:7.png]]
351 +
352 +8.Open the RSLogix 500Pro software and select [System Comms...] in the [Comms] option.[[image:8.jpg]]
353 +
354 +9.Select the driver you have created. All device nodes in the same LAN as the computer will be scanned. Select the PLC to be connected and click [OK].
355 +
356 +[[image:9.png]]
357 +
358 +10.Click Comms [Go Online].[[image:10.png]]
359 +
360 +11.Click [YES] in the pop-up window.[[image:11.png]]
361 +
362 +12.Enter online mode.[[image:14.jpg]]
363 +
364 +**Cable Wiring**
365 +
366 +(% style="text-align:center" %)
367 +[[image:Ethernet.png]]
1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +22.0 KB
Content
10.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +112.1 KB
Content
11.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +68.6 KB
Content
14.jpg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +70.0 KB
Content
2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +32.2 KB
Content
3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +39.2 KB
Content
4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +36.5 KB
Content
5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +25.0 KB
Content
6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +18.0 KB
Content
7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +24.7 KB
Content
8.jpg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +116.6 KB
Content
9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +74.5 KB
Content
Ethernet.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +107.1 KB
Content