... ... @@ -173,55 +173,6 @@
173 173  
174 174  {{id name="I12.PLCProtocol_html_58205bdf82c06d4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_32d8ab10ec374ea6.png||alt="12.PLC Protocol_html_58205bdf82c06d4.png" height="307" width="500"]]
175 175  
176 -== {{id name="HEtherNet2FIP28CompactLogixSeries29"/}}**EtherNet/IP(CompactLogix Series)** ==
177 -
178 -Allen-Brandly Compact Logix Free Tag
179 -
180 -**HMI Settings**
181 -
182 -|**Items**|**Settings**|**Note**
183 -|Protocol|EtherNet/IP(CompactLogix Series)|
184 -|Connection|Ethernet|
185 -|Port No.|44818|
186 -
187 -**PLC Setting**
188 -
189 -Create new tags
190 -
191 -{{id name="I12.PLCProtocol_html_a748a27dcf7f1124.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_75d3f4097ac67d8e.png||alt="12.PLC Protocol_html_a748a27dcf7f1124.png" height="411" width="700"]]
192 -
193 -Export tags to CSV file. ([Tools] » [Export] » [Tags and Logic Comments])
194 -
195 -{{id name="I12.PLCProtocol_html_151379170bb8ff3e.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_39bb299de26a0af0.png||alt="12.PLC Protocol_html_151379170bb8ff3e.png" height="352" width="700"]]
196 -
197 -Import labels, please open [Communication] window and click [Import label];
198 -
199 -Select csv file, all tags will be displayed as belows;
200 -
201 -{{id name="I12.PLCProtocol_html_af192e54dee96f38.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4216defdc24cba39.png||alt="12.PLC Protocol_html_af192e54dee96f38.png" height="586" width="700"]]
202 -
203 -**✎Note:**
204 -
205 -Because in different region, the separation symbol is different, we suggest you check this before you want to import your tags. To open csv file as text format.
206 -
207 -{{id name="I12.PLCProtocol_html_33df1d63ebe53726.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_24f4d658173f88a9.png||alt="12.PLC Protocol_html_33df1d63ebe53726.png" height="206" width="700"]]
208 -
209 -The directory of changing system settings: [Control Panel] -> [Date, Time, Language,and Regional Options] -> [Change the format of numbers, dates, and times]->[Customize]-> [List separator]. Please select [,] and export CSV file after setting.
210 -
211 -**Communication settings in HMI**
212 -
213 -Enable HMI Ethernet in [Project Settings];
214 -
215 -{{id name="I12.PLCProtocol_html_43b671f18153910d.png-5"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png||alt="12.PLC Protocol_html_43b671f18153910d.png" height="106" width="400"]]
216 -
217 -Set PLC IP in [Device IP] settings;
218 -
219 -{{id name="I12.PLCProtocol_html_27870d373581892e.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_10385ddd81c8baff.png||alt="12.PLC Protocol_html_27870d373581892e.png" height="206" width="600"]]
220 -
221 -**Cable Wiring**
222 -
223 -{{id name="I12.PLCProtocol_html_2297240b57346b2a.png-3"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="400"]]
224 -
225 225  == {{id name="HMicroLogix1200"/}}**MicroLogix 1200** ==
226 226  
227 227  The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200.
... ... @@ -253,7 +253,7 @@
253 253  Supported Series: Rockwell MicroLogix 1100, 1400, SLC5/05 Ethernet port. MicroLogix1000,1200,1500,SLC 5/03, 5/04 with 1761-NET-ENI
254 254  
255 255  |**Items**|**Settings**|**Note**
256 -|Protocol|Rock well Ethernet/IP DF1|
207 +|Protocol|Rockwell Ethernet/IP DF1|
257 257  |Connection|Ethernet|
258 258  |Port No.|44818|
259 259  |PLC station No.|1|
... ... @@ -331,10 +331,6 @@
331 331  )))
332 332  |LN|LNddddd|0~~99255|Long
333 333  
334 -**Cable Wiring**
335 -
336 -[[image:Ethernet.png]]
337 -
338 338  **PLC Setting:**
339 339  
340 340  1.Open the RSLinx Classic Lite software and click [Configure Drivers...] in [Communications].[[image:1.png]]
... ... @@ -343,8 +343,10 @@
343 343  
344 344  3.Click Add New and a pop-up window will pop up. Name the driver and click [OK] in the pop-up window.[[image:3.png]]
345 345  
346 -4.The configuration driver window pops up., click on the correct network adapter option (such as the ASIX USB to Fast Ethernet Family Adapter option in this picture), and click OK[[image:4.png]]
293 +4.The configuration driver window pops up., click on the correct network adapter option (such as the ASIX USB to Fast Ethernet Family Adapter option in this picture), and click OK
347 347  
295 +[[image:4.png]]
296 +
348 348  5.Click the [Close] button.[[image:5.png]]
349 349  
350 350  6.Click the [RSWho] button.[[image:6.png]]
... ... @@ -351,7 +351,7 @@
351 351  
352 352  7.Pop up the RS Who window, indicating that the driver has been added successfully.[[image:7.png]]
353 353  
354 -8.Open the RSLogix 500Pro software and select [System Comms...] in the [Comms option].[[image:8.jpg]]
303 +8.Open the RSLogix 500Pro software and select [System Comms...] in the [Comms] option.[[image:8.jpg]]
355 355  
356 356  9.Select the driver you have created. All device nodes in the same LAN as the computer will be scanned. Select the PLC to be connected and click [OK].
357 357  
... ... @@ -362,3 +362,165 @@
362 362  11.Click [YES] in the pop-up window.[[image:11.png]]
363 363  
364 364  12.Enter online mode.[[image:14.jpg]]
314 +
315 +**Cable Wiring**
316 +
317 +(% style="text-align:center" %)
318 +[[image:Ethernet.png]]
319 +
320 +
321 +== **EtherNet/IP(CompactLogix Series)** ==
322 +
323 +Supported Series: Rockwell CompactLogix Series Ethernet
324 +
325 +|**Items**|**Settings**|**Note**
326 +|Protocol|Rockwell EtherNet/IP (CompactLogix Series)|
327 +|Connection|Ethernet|
328 +|Port No.|44818|
329 +|PLC station No.|1|
330 +
331 +**Support Variable Type**
332 +
333 +|PLC data type|Bit/Word|PIStudio data format|Memo
334 +|BOOL|Boolean|Bit object|
335 +|BitArray| | |
336 +|SINT| | |-128-127
337 +|USINT| | |0~~255
338 +|INT|Integer|16-bit signed, ASCll|-32768~~32767
339 +|UINT| | |0~~65535
340 +|DINT|Double integer|32-bit signed|-2^31~~(2^31-1)
341 +|UDINT| | |0~~4294967295
342 +|REAL|Single Precision Float|32-bit floating|
343 +|LINT|Long integer|64-bit signed|
344 +|ULINT|Long integer|64-bit unsigned|
345 +|LREAL|Double Precision Float|64-bit double|
346 +|STRING| | |Enable Read DWord
347 +
348 +**PLC Setting:**
349 +
350 +1.Open the RSLinx Classic Lite software and click [Configure Drivers...] in [Communications].
351 +
352 +[[image:1726907484077-900.png]]
353 +
354 +2.Click the drop-down menu and select EtherNet/IP driver
355 +
356 +[[image:1726907484081-522.png]]
357 +
358 +3.Click Add New and a pop-up window will pop up. Name the driver and click [OK] in the pop-up window.
359 +
360 +[[image:1726907484084-295.png]]
361 +
362 +4.The configuration driver window pops up., click on the correct network adapter option (such as the ASIX USB to Fast Ethernet Family Adapter option in this picture), and click [OK].
363 +
364 +[[image:1726907484085-985.png]]
365 +
366 +5.Click the [Close] button
367 +
368 +[[image:1726907484087-419.png]]
369 +
370 +6.Open Stuido5000 and create a new project or open an existing project.
371 +
372 +To create a new project: click [New Project].
373 +
374 +(% style="text-align:center" %)
375 +[[image:1726907578613-886.png]]
376 +
377 +7.Click the [1769-L16ER-BB1B]→ Edit Project Name → Select the file storage location → [Next]
378 +
379 +(% style="text-align:center" %)
380 +[[image:1726907578645-890.png]]
381 +
382 +8. Select the software version →Select [Expansion I/O] number→ Security Authority → Click [Finish].
383 +
384 +The software version must be the same as the PLC firmware version, and the Security Authority protection should be selected according to personal needs.
385 +
386 +(% style="text-align:center" %)
387 +[[image:1726907578647-323.png]]
388 +
389 +**~ Create a new tag**
390 +
391 +1.Click the drop-down menu on the left of [Controller ABcs]→ Right-click [Controller Tags] → Click [New tag].
392 +
393 +[[image:1726907578648-590.png]]
394 +
395 +2.Input tag name → Select tag type → Create
396 +
397 +(% style="text-align:center" %)
398 +[[image:1726907578652-543.png]]
399 +
400 +Establishing communication
401 +
402 +1.Click [Communications]→Click[Who Active].
403 +
404 +(% style="text-align:center" %)
405 +[[image:6.jpg]]
406 +
407 +2.Select the drive → Select the corresponding PLC →Click [Go Online].
408 +
409 +The driver is a new created driver from step 1.2
410 +
411 +(% style="text-align:center" %)
412 +[[image:1726908219964-183.png]]
413 +
414 +3.Click [Download]
415 +
416 +(% style="text-align:center" %)
417 +[[image:1726908219966-477.png]]
418 +
419 +4.Click [Download]→ [YES].
420 +
421 +(% style="text-align:center" %)
422 +[[image:1726908219968-250.png]]
423 +
424 +
425 +(% style="text-align:center" %)
426 +[[image:1726908219970-794.png]]
427 +
428 +
429 +**Export Tags**
430 +
431 +1.Click the drop-down menu on the left of [Controller ABcs]→Right-click [Controller Tags]→ Click [Export Tags].
432 +
433 +(% style="text-align:center" %)
434 +[[image:11.jpg]]
435 +
436 +2.Edit the tag file name → Select the file storage location → [Export].
437 +
438 +(% style="text-align:center" %)
439 +[[image:1726908448582-442.png]]
440 +
441 + **HMI Setting:**
442 +
443 +① [Project]→[Communication]→[Setting]
444 +
445 +[[image:1726909065716-860.png]]
446 +
447 +② Choose protocol:
448 +
449 + Device type [Rockwell]→[Rockwell EtherNet/IP(CompactLogix Series)]→[OK]
450 +
451 +(% style="text-align:center" %)
452 +[[image:1726909065723-657.png]]
453 +
454 +③[Setting]→[PLC IP Address]→[OK]→[Labels manage].
455 +
456 +(% style="text-align:center" %)
457 +[[image:1726909065724-657.png]]
458 +
459 +④Tags import:
460 +
461 +[Import Tags From File]→Choose the .CSV file→[Open]→[Save]→[OK]
462 +
463 +(% style="text-align:center" %)
464 +[[image:1726909065726-124.png]]
465 +
466 +**Project making**
467 +
468 +①Using PIStudio to program a HMI project depending on the requirements.
469 +
470 +(% style="text-align:center" %)
471 +[[image:1726909065727-501.png]]
472 +
473 +②After programming[Compile], you can download the project into HMI when compilation complete.
474 +
475 +[[image:1726909065727-109.png]]
11.jpg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +70.8 KB
Content
1726907484077-900.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +22.0 KB
Content
1726907484081-522.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +32.2 KB
Content
1726907484084-295.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +39.2 KB
Content
1726907484085-985.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +36.5 KB
Content
1726907484087-419.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +25.0 KB
Content
1726907578613-886.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +220.3 KB
Content
1726907578645-890.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +34.1 KB
Content
1726907578647-323.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +27.9 KB
Content
1726907578648-590.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +105.8 KB
Content
1726907578652-543.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +19.1 KB
Content
1726908219954-418.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +132.7 KB
Content
1726908219964-183.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content
1726908219966-477.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +20.5 KB
Content
1726908219968-250.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +26.1 KB
Content
1726908219970-794.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +6.1 KB
Content
1726908448571-687.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +134.3 KB
Content
1726908448582-442.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +70.0 KB
Content
1726909065716-860.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +99.4 KB
Content
1726909065723-657.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +28.0 KB
Content
1726909065724-657.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +44.7 KB
Content
1726909065726-124.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +16.4 KB
Content
1726909065727-109.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +87.7 KB
Content
1726909065727-501.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +7.9 KB
Content
6.jpg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +69.3 KB
Content
Ethernet.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Molly
Size
... ... @@ -1,0 +1,1 @@
1 +107.1 KB
Content