@@ -173,55 +173,6 @@ |
173 |
173 |
|
174 |
174 |
{{id name="I12.PLCProtocol_html_58205bdf82c06d4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_32d8ab10ec374ea6.png||alt="12.PLC Protocol_html_58205bdf82c06d4.png" height="307" width="500"]] |
175 |
175 |
|
176 |
|
-== {{id name="HEtherNet2FIP28CompactLogixSeries29"/}}**EtherNet/IP(CompactLogix Series)** == |
177 |
|
- |
178 |
|
-Allen-Brandly Compact Logix Free Tag |
179 |
|
- |
180 |
|
-**HMI Settings** |
181 |
|
- |
182 |
|
-|**Items**|**Settings**|**Note** |
183 |
|
-|Protocol|EtherNet/IP(CompactLogix Series)| |
184 |
|
-|Connection|Ethernet| |
185 |
|
-|Port No.|44818| |
186 |
|
- |
187 |
|
-**PLC Setting** |
188 |
|
- |
189 |
|
-Create new tags |
190 |
|
- |
191 |
|
-{{id name="I12.PLCProtocol_html_a748a27dcf7f1124.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_75d3f4097ac67d8e.png||alt="12.PLC Protocol_html_a748a27dcf7f1124.png" height="411" width="700"]] |
192 |
|
- |
193 |
|
-Export tags to CSV file. ([Tools] » [Export] » [Tags and Logic Comments]) |
194 |
|
- |
195 |
|
-{{id name="I12.PLCProtocol_html_151379170bb8ff3e.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_39bb299de26a0af0.png||alt="12.PLC Protocol_html_151379170bb8ff3e.png" height="352" width="700"]] |
196 |
|
- |
197 |
|
-Import labels, please open [Communication] window and click [Import label]; |
198 |
|
- |
199 |
|
-Select csv file, all tags will be displayed as belows; |
200 |
|
- |
201 |
|
-{{id name="I12.PLCProtocol_html_af192e54dee96f38.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4216defdc24cba39.png||alt="12.PLC Protocol_html_af192e54dee96f38.png" height="586" width="700"]] |
202 |
|
- |
203 |
|
-**✎Note:** |
204 |
|
- |
205 |
|
-Because in different region, the separation symbol is different, we suggest you check this before you want to import your tags. To open csv file as text format. |
206 |
|
- |
207 |
|
-{{id name="I12.PLCProtocol_html_33df1d63ebe53726.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_24f4d658173f88a9.png||alt="12.PLC Protocol_html_33df1d63ebe53726.png" height="206" width="700"]] |
208 |
|
- |
209 |
|
-The directory of changing system settings: [Control Panel] -> [Date, Time, Language,and Regional Options] -> [Change the format of numbers, dates, and times]->[Customize]-> [List separator]. Please select [,] and export CSV file after setting. |
210 |
|
- |
211 |
|
-**Communication settings in HMI** |
212 |
|
- |
213 |
|
-Enable HMI Ethernet in [Project Settings]; |
214 |
|
- |
215 |
|
-{{id name="I12.PLCProtocol_html_43b671f18153910d.png-5"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png||alt="12.PLC Protocol_html_43b671f18153910d.png" height="106" width="400"]] |
216 |
|
- |
217 |
|
-Set PLC IP in [Device IP] settings; |
218 |
|
- |
219 |
|
-{{id name="I12.PLCProtocol_html_27870d373581892e.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_10385ddd81c8baff.png||alt="12.PLC Protocol_html_27870d373581892e.png" height="206" width="600"]] |
220 |
|
- |
221 |
|
-**Cable Wiring** |
222 |
|
- |
223 |
|
-{{id name="I12.PLCProtocol_html_2297240b57346b2a.png-3"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="400"]] |
224 |
|
- |
225 |
225 |
== {{id name="HMicroLogix1200"/}}**MicroLogix 1200** == |
226 |
226 |
|
227 |
227 |
The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200. |
... |
... |
@@ -367,7 +367,7 @@ |
367 |
367 |
[[image:Ethernet.png]] |
368 |
368 |
|
369 |
369 |
|
370 |
|
-= Rockwell EtherNet/IP(CompactLogix Series) = |
|
321 |
+== **EtherNet/IP(CompactLogix Series)** == |
371 |
371 |
|
372 |
372 |
Supported Series: Rockwell CompactLogix Series Ethernet |
373 |
373 |
|
... |
... |
@@ -394,4 +394,131 @@ |
394 |
394 |
|LREAL|Double Precision Float|64-bit double| |
395 |
395 |
|STRING| | |Enable Read DWord |
396 |
396 |
|
397 |
|
- |
|
348 |
+**PLC Setting:** |
|
349 |
+ |
|
350 |
+1.Open the RSLinx Classic Lite software and click [Configure Drivers...] in [Communications]. |
|
351 |
+ |
|
352 |
+[[image:1726907484077-900.png]] |
|
353 |
+ |
|
354 |
+2.Click the drop-down menu and select EtherNet/IP driver |
|
355 |
+ |
|
356 |
+[[image:1726907484081-522.png]] |
|
357 |
+ |
|
358 |
+3.Click Add New and a pop-up window will pop up. Name the driver and click [OK] in the pop-up window. |
|
359 |
+ |
|
360 |
+[[image:1726907484084-295.png]] |
|
361 |
+ |
|
362 |
+4.The configuration driver window pops up., click on the correct network adapter option (such as the ASIX USB to Fast Ethernet Family Adapter option in this picture), and click [OK]. |
|
363 |
+ |
|
364 |
+[[image:1726907484085-985.png]] |
|
365 |
+ |
|
366 |
+5.Click the [Close] button |
|
367 |
+ |
|
368 |
+[[image:1726907484087-419.png]] |
|
369 |
+ |
|
370 |
+6.Open Stuido5000 and create a new project or open an existing project. |
|
371 |
+ |
|
372 |
+To create a new project: click [New Project]. |
|
373 |
+ |
|
374 |
+(% style="text-align:center" %) |
|
375 |
+[[image:1726907578613-886.png]] |
|
376 |
+ |
|
377 |
+7.Click the [1769-L16ER-BB1B]→ Edit Project Name → Select the file storage location → [Next] |
|
378 |
+ |
|
379 |
+(% style="text-align:center" %) |
|
380 |
+[[image:1726907578645-890.png]] |
|
381 |
+ |
|
382 |
+8. Select the software version →Select [Expansion I/O] number→ Security Authority → Click [Finish]. |
|
383 |
+ |
|
384 |
+The software version must be the same as the PLC firmware version, and the Security Authority protection should be selected according to personal needs. |
|
385 |
+ |
|
386 |
+(% style="text-align:center" %) |
|
387 |
+[[image:1726907578647-323.png]] |
|
388 |
+ |
|
389 |
+**~ Create a new tag** |
|
390 |
+ |
|
391 |
+1.Click the drop-down menu on the left of [Controller ABcs]→ Right-click [Controller Tags] → Click [New tag]. |
|
392 |
+ |
|
393 |
+[[image:1726907578648-590.png]] |
|
394 |
+ |
|
395 |
+2.Input tag name → Select tag type → Create |
|
396 |
+ |
|
397 |
+(% style="text-align:center" %) |
|
398 |
+[[image:1726907578652-543.png]] |
|
399 |
+ |
|
400 |
+Establishing communication |
|
401 |
+ |
|
402 |
+1.Click [Communications]→Click[Who Active]. |
|
403 |
+ |
|
404 |
+(% style="text-align:center" %) |
|
405 |
+[[image:6.jpg]] |
|
406 |
+ |
|
407 |
+2.Select the drive → Select the corresponding PLC →Click [Go Online]. |
|
408 |
+ |
|
409 |
+The driver is a new created driver from step 1.2 |
|
410 |
+ |
|
411 |
+(% style="text-align:center" %) |
|
412 |
+[[image:1726908219964-183.png]] |
|
413 |
+ |
|
414 |
+3.Click [Download] |
|
415 |
+ |
|
416 |
+(% style="text-align:center" %) |
|
417 |
+[[image:1726908219966-477.png]] |
|
418 |
+ |
|
419 |
+4.Click [Download]→ [YES]. |
|
420 |
+ |
|
421 |
+(% style="text-align:center" %) |
|
422 |
+[[image:1726908219968-250.png]] |
|
423 |
+ |
|
424 |
+ |
|
425 |
+(% style="text-align:center" %) |
|
426 |
+[[image:1726908219970-794.png]] |
|
427 |
+ |
|
428 |
+ |
|
429 |
+**Export Tags** |
|
430 |
+ |
|
431 |
+1.Click the drop-down menu on the left of [Controller ABcs]→Right-click [Controller Tags]→ Click [Export Tags]. |
|
432 |
+ |
|
433 |
+(% style="text-align:center" %) |
|
434 |
+[[image:11.jpg]] |
|
435 |
+ |
|
436 |
+2.Edit the tag file name → Select the file storage location → [Export]. |
|
437 |
+ |
|
438 |
+(% style="text-align:center" %) |
|
439 |
+[[image:1726908448582-442.png]] |
|
440 |
+ |
|
441 |
+ **HMI Setting:** |
|
442 |
+ |
|
443 |
+① [Project]→[Communication]→[Setting] |
|
444 |
+ |
|
445 |
+[[image:1726909065716-860.png]] |
|
446 |
+ |
|
447 |
+② Choose protocol: |
|
448 |
+ |
|
449 |
+ Device type [Rockwell]→[Rockwell EtherNet/IP(CompactLogix Series)]→[OK] |
|
450 |
+ |
|
451 |
+(% style="text-align:center" %) |
|
452 |
+[[image:1726909065723-657.png]] |
|
453 |
+ |
|
454 |
+③[Setting]→[PLC IP Address]→[OK]→[Labels manage]. |
|
455 |
+ |
|
456 |
+(% style="text-align:center" %) |
|
457 |
+[[image:1726909065724-657.png]] |
|
458 |
+ |
|
459 |
+④Tags import: |
|
460 |
+ |
|
461 |
+[Import Tags From File]→Choose the .CSV file→[Open]→[Save]→[OK] |
|
462 |
+ |
|
463 |
+(% style="text-align:center" %) |
|
464 |
+[[image:1726909065726-124.png]] |
|
465 |
+ |
|
466 |
+**Project making** |
|
467 |
+ |
|
468 |
+①Using PIStudio to program a HMI project depending on the requirements. |
|
469 |
+ |
|
470 |
+(% style="text-align:center" %) |
|
471 |
+[[image:1726909065727-501.png]] |
|
472 |
+ |
|
473 |
+②After programming[Compile], you can download the project into HMI when compilation complete. |
|
474 |
+ |
|
475 |
+[[image:1726909065727-109.png]] |