@@ -253,7 +253,7 @@ |
253 |
253 |
Supported Series: Rockwell MicroLogix 1100, 1400, SLC5/05 Ethernet port. MicroLogix1000,1200,1500,SLC 5/03, 5/04 with 1761-NET-ENI |
254 |
254 |
|
255 |
255 |
|**Items**|**Settings**|**Note** |
256 |
|
-|Protocol|Rockwell Ethernet/IP DF1| |
|
256 |
+|Protocol|Rock well Ethernet/IP DF1| |
257 |
257 |
|Connection|Ethernet| |
258 |
258 |
|Port No.|44818| |
259 |
259 |
|PLC station No.|1| |
... |
... |
@@ -331,6 +331,10 @@ |
331 |
331 |
))) |
332 |
332 |
|LN|LNddddd|0~~99255|Long |
333 |
333 |
|
|
334 |
+**Cable Wiring** |
|
335 |
+ |
|
336 |
+[[image:Ethernet.png]] |
|
337 |
+ |
334 |
334 |
**PLC Setting:** |
335 |
335 |
|
336 |
336 |
1.Open the RSLinx Classic Lite software and click [Configure Drivers...] in [Communications].[[image:1.png]] |
... |
... |
@@ -339,10 +339,8 @@ |
339 |
339 |
|
340 |
340 |
3.Click Add New and a pop-up window will pop up. Name the driver and click [OK] in the pop-up window.[[image:3.png]] |
341 |
341 |
|
342 |
|
-4.The configuration driver window pops up., click on the correct network adapter option (such as the ASIX USB to Fast Ethernet Family Adapter option in this picture), and click OK |
|
346 |
+4.The configuration driver window pops up., click on the correct network adapter option (such as the ASIX USB to Fast Ethernet Family Adapter option in this picture), and click OK[[image:4.png]] |
343 |
343 |
|
344 |
|
-[[image:4.png]] |
345 |
|
- |
346 |
346 |
5.Click the [Close] button.[[image:5.png]] |
347 |
347 |
|
348 |
348 |
6.Click the [RSWho] button.[[image:6.png]] |
... |
... |
@@ -349,7 +349,7 @@ |
349 |
349 |
|
350 |
350 |
7.Pop up the RS Who window, indicating that the driver has been added successfully.[[image:7.png]] |
351 |
351 |
|
352 |
|
-8.Open the RSLogix 500Pro software and select [System Comms...] in the [Comms] option.[[image:8.jpg]] |
|
354 |
+8.Open the RSLogix 500Pro software and select [System Comms...] in the [Comms option].[[image:8.jpg]] |
353 |
353 |
|
354 |
354 |
9.Select the driver you have created. All device nodes in the same LAN as the computer will be scanned. Select the PLC to be connected and click [OK]. |
355 |
355 |
|
... |
... |
@@ -360,89 +360,3 @@ |
360 |
360 |
11.Click [YES] in the pop-up window.[[image:11.png]] |
361 |
361 |
|
362 |
362 |
12.Enter online mode.[[image:14.jpg]] |
363 |
|
- |
364 |
|
-**Cable Wiring** |
365 |
|
- |
366 |
|
-(% style="text-align:center" %) |
367 |
|
-[[image:Ethernet.png]] |
368 |
|
- |
369 |
|
- |
370 |
|
-= Rockwell EtherNet/IP(CompactLogix Series) = |
371 |
|
- |
372 |
|
-Supported Series: Rockwell CompactLogix Series Ethernet |
373 |
|
- |
374 |
|
-|**Items**|**Settings**|**Note** |
375 |
|
-|Protocol|Rockwell EtherNet/IP (CompactLogix Series)| |
376 |
|
-|Connection|Ethernet| |
377 |
|
-|Port No.|44818| |
378 |
|
-|PLC station No.|1| |
379 |
|
- |
380 |
|
-**Support Variable Type** |
381 |
|
- |
382 |
|
-|PLC data type|Bit/Word|PIStudio data format|Memo |
383 |
|
-|BOOL|Boolean|Bit object| |
384 |
|
-|BitArray| | | |
385 |
|
-|SINT| | |-128-127 |
386 |
|
-|USINT| | |0~~255 |
387 |
|
-|INT|Integer|16-bit signed, ASCll|-32768~~32767 |
388 |
|
-|UINT| | |0~~65535 |
389 |
|
-|DINT|Double integer|32-bit signed|-2^31~~(2^31-1) |
390 |
|
-|UDINT| | |0~~4294967295 |
391 |
|
-|REAL|Single Precision Float|32-bit floating| |
392 |
|
-|LINT|Long integer|64-bit signed| |
393 |
|
-|ULINT|Long integer|64-bit unsigned| |
394 |
|
-|LREAL|Double Precision Float|64-bit double| |
395 |
|
-|STRING| | |Enable Read DWord |
396 |
|
- |
397 |
|
-**PLC Setting:** |
398 |
|
- |
399 |
|
-1.Open the RSLinx Classic Lite software and click [Configure Drivers...] in [Communications]. |
400 |
|
- |
401 |
|
-[[image:1726907484077-900.png]] |
402 |
|
- |
403 |
|
-2.Click the drop-down menu and select EtherNet/IP driver |
404 |
|
- |
405 |
|
-[[image:1726907484081-522.png]] |
406 |
|
- |
407 |
|
-3.Click Add New and a pop-up window will pop up. Name the driver and click [OK] in the pop-up window. |
408 |
|
- |
409 |
|
-[[image:1726907484084-295.png]] |
410 |
|
- |
411 |
|
-4.The configuration driver window pops up., click on the correct network adapter option (such as the ASIX USB to Fast Ethernet Family Adapter option in this picture), and click [OK]. |
412 |
|
- |
413 |
|
-[[image:1726907484085-985.png]] |
414 |
|
- |
415 |
|
-5.Click the [Close] button |
416 |
|
- |
417 |
|
-[[image:1726907484087-419.png]] |
418 |
|
- |
419 |
|
-6.Open Stuido5000 and create a new project or open an existing project. |
420 |
|
- |
421 |
|
-To create a new project: click [New Project]. |
422 |
|
- |
423 |
|
-[[image:1726907578613-886.png]] |
424 |
|
- |
425 |
|
-7.Click the [1769-L16ER-BB1B]→ Edit Project Name → Select the file storage location → [Next] |
426 |
|
- |
427 |
|
-(% style="text-align:center" %) |
428 |
|
-[[image:1726907578645-890.png]] |
429 |
|
- |
430 |
|
-8. Select the software version →Select [Expansion I/O] number→ Security Authority → Click [Finish]. |
431 |
|
- |
432 |
|
-The software version must be the same as the PLC firmware version, and the Security Authority protection should be selected according to personal needs. |
433 |
|
- |
434 |
|
-(% style="text-align:center" %) |
435 |
|
-[[image:1726907578647-323.png]] |
436 |
|
- |
437 |
|
-**~ Create a new tag** |
438 |
|
- |
439 |
|
-1.Click the drop-down menu on the left of [Controller ABcs]→ Right-click [Controller Tags] → Click [New tag]. |
440 |
|
- |
441 |
|
-[[image:1726907578648-590.png]] |
442 |
|
- |
443 |
|
-2.Input tag name → Select tag type → Create |
444 |
|
- |
445 |
|
-(% style="text-align:center" %) |
446 |
|
-[[image:1726907578652-543.png]] |
447 |
|
- |
448 |
|
- |