Changes for page Rockwell

Last modified by Molly on 2024/11/04 18:13

From version 23.1
edited by Molly
on 2024/09/24 15:02
Change comment: There is no comment for this version
To version 17.2
edited by Molly
on 2024/09/21 16:36
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -173,6 +173,55 @@
173 173  
174 174  {{id name="I12.PLCProtocol_html_58205bdf82c06d4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_32d8ab10ec374ea6.png||alt="12.PLC Protocol_html_58205bdf82c06d4.png" height="307" width="500"]]
175 175  
176 +== {{id name="HEtherNet2FIP28CompactLogixSeries29"/}}**EtherNet/IP(CompactLogix Series)** ==
177 +
178 +Allen-Brandly Compact Logix Free Tag
179 +
180 +**HMI Settings**
181 +
182 +|**Items**|**Settings**|**Note**
183 +|Protocol|EtherNet/IP(CompactLogix Series)|
184 +|Connection|Ethernet|
185 +|Port No.|44818|
186 +
187 +**PLC Setting**
188 +
189 +Create new tags
190 +
191 +{{id name="I12.PLCProtocol_html_a748a27dcf7f1124.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_75d3f4097ac67d8e.png||alt="12.PLC Protocol_html_a748a27dcf7f1124.png" height="411" width="700"]]
192 +
193 +Export tags to CSV file. ([Tools] » [Export] » [Tags and Logic Comments])
194 +
195 +{{id name="I12.PLCProtocol_html_151379170bb8ff3e.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_39bb299de26a0af0.png||alt="12.PLC Protocol_html_151379170bb8ff3e.png" height="352" width="700"]]
196 +
197 +Import labels, please open [Communication] window and click [Import label];
198 +
199 +Select csv file, all tags will be displayed as belows;
200 +
201 +{{id name="I12.PLCProtocol_html_af192e54dee96f38.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4216defdc24cba39.png||alt="12.PLC Protocol_html_af192e54dee96f38.png" height="586" width="700"]]
202 +
203 +**✎Note:**
204 +
205 +Because in different region, the separation symbol is different, we suggest you check this before you want to import your tags. To open csv file as text format.
206 +
207 +{{id name="I12.PLCProtocol_html_33df1d63ebe53726.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_24f4d658173f88a9.png||alt="12.PLC Protocol_html_33df1d63ebe53726.png" height="206" width="700"]]
208 +
209 +The directory of changing system settings: [Control Panel] -> [Date, Time, Language,and Regional Options] -> [Change the format of numbers, dates, and times]->[Customize]-> [List separator]. Please select [,] and export CSV file after setting.
210 +
211 +**Communication settings in HMI**
212 +
213 +Enable HMI Ethernet in [Project Settings];
214 +
215 +{{id name="I12.PLCProtocol_html_43b671f18153910d.png-5"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png||alt="12.PLC Protocol_html_43b671f18153910d.png" height="106" width="400"]]
216 +
217 +Set PLC IP in [Device IP] settings;
218 +
219 +{{id name="I12.PLCProtocol_html_27870d373581892e.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_10385ddd81c8baff.png||alt="12.PLC Protocol_html_27870d373581892e.png" height="206" width="600"]]
220 +
221 +**Cable Wiring**
222 +
223 +{{id name="I12.PLCProtocol_html_2297240b57346b2a.png-3"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="400"]]
224 +
176 176  == {{id name="HMicroLogix1200"/}}**MicroLogix 1200** ==
177 177  
178 178  The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200.
... ... @@ -318,7 +318,7 @@
318 318  [[image:Ethernet.png]]
319 319  
320 320  
321 -== **EtherNet/IP(CompactLogix Series)** ==
370 += Rockwell EtherNet/IP(CompactLogix Series) =
322 322  
323 323  Supported Series: Rockwell CompactLogix Series Ethernet
324 324  
... ... @@ -371,7 +371,6 @@
371 371  
372 372  To create a new project: click [New Project].
373 373  
374 -(% style="text-align:center" %)
375 375  [[image:1726907578613-886.png]]
376 376  
377 377  7.Click the [1769-L16ER-BB1B]→ Edit Project Name → Select the file storage location → [Next]
... ... @@ -397,79 +397,4 @@
397 397  (% style="text-align:center" %)
398 398  [[image:1726907578652-543.png]]
399 399  
400 -Establishing communication
401 -
402 -1.Click [Communications]→Click[Who Active].
403 -
404 -(% style="text-align:center" %)
405 -[[image:6.jpg]]
406 -
407 -2.Select the drive → Select the corresponding PLC →Click [Go Online].
408 -
409 -The driver is a new created driver from step 1.2
410 -
411 -(% style="text-align:center" %)
412 -[[image:1726908219964-183.png]]
413 -
414 -3.Click [Download]
415 -
416 -(% style="text-align:center" %)
417 -[[image:1726908219966-477.png]]
418 -
419 -4.Click [Download]→ [YES].
420 -
421 -(% style="text-align:center" %)
422 -[[image:1726908219968-250.png]]
423 -
424 -
425 -(% style="text-align:center" %)
426 -[[image:1726908219970-794.png]]
427 -
428 -
429 -**Export Tags**
430 -
431 -1.Click the drop-down menu on the left of [Controller ABcs]→Right-click [Controller Tags]→ Click [Export Tags].
432 -
433 -(% style="text-align:center" %)
434 -[[image:11.jpg]]
435 -
436 -2.Edit the tag file name → Select the file storage location → [Export].
437 -
438 -(% style="text-align:center" %)
439 -[[image:1726908448582-442.png]]
440 -
441 - **HMI Setting:**
442 -
443 -① [Project]→[Communication]→[Setting]
444 -
445 -[[image:1726909065716-860.png]]
446 -
447 -② Choose protocol:
448 -
449 - Device type [Rockwell]→[Rockwell EtherNet/IP(CompactLogix Series)]→[OK]
450 -
451 -(% style="text-align:center" %)
452 -[[image:1726909065723-657.png]]
453 -
454 -③[Setting]→[PLC IP Address]→[OK]→[Labels manage].
455 -
456 -(% style="text-align:center" %)
457 -[[image:1726909065724-657.png]]
458 -
459 -④Tags import:
460 -
461 -[Import Tags From File]→Choose the .CSV file→[Open]→[Save]→[OK]
462 -
463 -(% style="text-align:center" %)
464 -[[image:1726909065726-124.png]]
465 -
466 -**Project making**
467 -
468 -①Using PIStudio to program a HMI project depending on the requirements.
469 -
470 -(% style="text-align:center" %)
471 -[[image:1726909065727-501.png]]
472 -
473 -②After programming[Compile], you can download the project into HMI when compilation complete.
474 -
475 -[[image:1726909065727-109.png]]
448 +
11.jpg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Molly
Size
... ... @@ -1,1 +1,0 @@
1 -70.8 KB
Content
1726908219954-418.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Molly
Size
... ... @@ -1,1 +1,0 @@
1 -132.7 KB
Content
1726908219964-183.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Molly
Size
... ... @@ -1,1 +1,0 @@
1 -24.9 KB
Content
1726908219966-477.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Molly
Size
... ... @@ -1,1 +1,0 @@
1 -20.5 KB
Content
1726908219968-250.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Molly
Size
... ... @@ -1,1 +1,0 @@
1 -26.1 KB
Content
1726908219970-794.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Molly
Size
... ... @@ -1,1 +1,0 @@
1 -6.1 KB
Content
1726908448571-687.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Molly
Size
... ... @@ -1,1 +1,0 @@
1 -134.3 KB
Content
1726908448582-442.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Molly
Size
... ... @@ -1,1 +1,0 @@
1 -70.0 KB
Content
1726909065716-860.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Molly
Size
... ... @@ -1,1 +1,0 @@
1 -99.4 KB
Content
1726909065723-657.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Molly
Size
... ... @@ -1,1 +1,0 @@
1 -28.0 KB
Content
1726909065724-657.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Molly
Size
... ... @@ -1,1 +1,0 @@
1 -44.7 KB
Content
1726909065726-124.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Molly
Size
... ... @@ -1,1 +1,0 @@
1 -16.4 KB
Content
1726909065727-109.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Molly
Size
... ... @@ -1,1 +1,0 @@
1 -87.7 KB
Content
1726909065727-501.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Molly
Size
... ... @@ -1,1 +1,0 @@
1 -7.9 KB
Content
6.jpg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Molly
Size
... ... @@ -1,1 +1,0 @@
1 -69.3 KB
Content