@@ -440,11 +440,20 @@ |
440 |
440 |
|
441 |
441 |
**HMI Setting:** |
442 |
442 |
|
443 |
|
-① [Project]→[Communication]→[Setting] |
444 |
444 |
|
|
444 |
+**~ New project** |
|
445 |
+ |
|
446 |
+1.[Home]→[New]→[New project]→Set the name,series and model of HMI→[Next]→[Screen style] →[OK]. |
|
447 |
+ |
|
448 |
+[[image:1727161664493-505.png]] |
|
449 |
+ |
|
450 |
+**Communication configuration** |
|
451 |
+ |
|
452 |
+1.[Project]→[Communication]→[Setting] |
|
453 |
+ |
445 |
445 |
[[image:1726909065716-860.png]] |
446 |
446 |
|
447 |
|
-② Choose protocol: |
|
456 |
+2.Choose protocol: |
448 |
448 |
|
449 |
449 |
Device type [Rockwell]→[Rockwell EtherNet/IP(CompactLogix Series)]→[OK] |
450 |
450 |
|
... |
... |
@@ -451,12 +451,12 @@ |
451 |
451 |
(% style="text-align:center" %) |
452 |
452 |
[[image:1726909065723-657.png]] |
453 |
453 |
|
454 |
|
-③[Setting]→[PLC IP Address]→[OK]→[Labels manage]. |
|
463 |
+3.[Setting]→[PLC IP Address]→[OK]→[Labels manage]. |
455 |
455 |
|
456 |
456 |
(% style="text-align:center" %) |
457 |
457 |
[[image:1726909065724-657.png]] |
458 |
458 |
|
459 |
|
-④Tags import: |
|
468 |
+4.Tags import: |
460 |
460 |
|
461 |
461 |
[Import Tags From File]→Choose the .CSV file→[Open]→[Save]→[OK] |
462 |
462 |
|
... |
... |
@@ -463,13 +463,47 @@ |
463 |
463 |
(% style="text-align:center" %) |
464 |
464 |
[[image:1726909065726-124.png]] |
465 |
465 |
|
466 |
|
-**Project making** |
|
475 |
+= Rockwell Micro850 Series = |
467 |
467 |
|
468 |
|
-①Using PIStudio to program a HMI project depending on the requirements. |
|
477 |
+1.Open Connected Components Workbench and create a new project or open an existing project. |
469 |
469 |
|
470 |
|
-(% style="text-align:center" %) |
471 |
|
-[[image:1726909065727-501.png]] |
|
479 |
+To create a new project: click [New Project]→Edit project name→Click [Browse]select project storage location→Click [Create]. |
472 |
472 |
|
473 |
|
-②After programming[Compile], you can download the project into HMI when compilation complete. |
|
481 |
+[[image:1730714903819-264.png]] |
474 |
474 |
|
475 |
|
-[[image:1726909065727-109.png]] |
|
483 |
+ |
|
484 |
+2.Click the [Controllers]→ [Micro850] → Select device model → [Add To Project]. |
|
485 |
+ |
|
486 |
+[[image:1730714903824-934.png]] |
|
487 |
+ |
|
488 |
+ |
|
489 |
+3. Double click [Global Variables]→Right click on a blank space in the table→ Click [Add Variable]. |
|
490 |
+ |
|
491 |
+[[image:1730714903826-298.png]] |
|
492 |
+ |
|
493 |
+ |
|
494 |
+4.Right click[Micro850]→ Click [Properties]. |
|
495 |
+ |
|
496 |
+[[image:1730714903828-952.png]] |
|
497 |
+ |
|
498 |
+5.Select Controller → Ethernet →Configure the IP address of the PLC. |
|
499 |
+ |
|
500 |
+[[image:1730714903830-866.png]] |
|
501 |
+ |
|
502 |
+ |
|
503 |
+6.Click [Download]→Choose your device→Click[OK]. |
|
504 |
+ |
|
505 |
+[[image:1730714903835-960.png]] |
|
506 |
+ |
|
507 |
+ |
|
508 |
+7.Click[Download]. |
|
509 |
+ |
|
510 |
+[[image:1730714903837-636.png]] |
|
511 |
+ |
|
512 |
+8. Right click [Micro850]→Click [Export]→Click [Variables]. |
|
513 |
+ |
|
514 |
+[[image:1730714903838-538.png]] |
|
515 |
+ |
|
516 |
+9.Edit the tag file name → Select the file storage location → [Export]. |
|
517 |
+ |
|
518 |
+[[image:1730714903840-999.png]] |