Changes for page Rockwell

Last modified by Molly on 2024/11/04 18:13

From version 24.1
edited by Molly
on 2024/09/24 15:08
Change comment: There is no comment for this version
To version 20.1
edited by Molly
on 2024/09/24 14:09
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -173,6 +173,55 @@
173 173  
174 174  {{id name="I12.PLCProtocol_html_58205bdf82c06d4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_32d8ab10ec374ea6.png||alt="12.PLC Protocol_html_58205bdf82c06d4.png" height="307" width="500"]]
175 175  
176 +== {{id name="HEtherNet2FIP28CompactLogixSeries29"/}}**EtherNet/IP(CompactLogix Series)** ==
177 +
178 +Allen-Brandly Compact Logix Free Tag
179 +
180 +**HMI Settings**
181 +
182 +|**Items**|**Settings**|**Note**
183 +|Protocol|EtherNet/IP(CompactLogix Series)|
184 +|Connection|Ethernet|
185 +|Port No.|44818|
186 +
187 +**PLC Setting**
188 +
189 +Create new tags
190 +
191 +{{id name="I12.PLCProtocol_html_a748a27dcf7f1124.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_75d3f4097ac67d8e.png||alt="12.PLC Protocol_html_a748a27dcf7f1124.png" height="411" width="700"]]
192 +
193 +Export tags to CSV file. ([Tools] » [Export] » [Tags and Logic Comments])
194 +
195 +{{id name="I12.PLCProtocol_html_151379170bb8ff3e.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_39bb299de26a0af0.png||alt="12.PLC Protocol_html_151379170bb8ff3e.png" height="352" width="700"]]
196 +
197 +Import labels, please open [Communication] window and click [Import label];
198 +
199 +Select csv file, all tags will be displayed as belows;
200 +
201 +{{id name="I12.PLCProtocol_html_af192e54dee96f38.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4216defdc24cba39.png||alt="12.PLC Protocol_html_af192e54dee96f38.png" height="586" width="700"]]
202 +
203 +**✎Note:**
204 +
205 +Because in different region, the separation symbol is different, we suggest you check this before you want to import your tags. To open csv file as text format.
206 +
207 +{{id name="I12.PLCProtocol_html_33df1d63ebe53726.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_24f4d658173f88a9.png||alt="12.PLC Protocol_html_33df1d63ebe53726.png" height="206" width="700"]]
208 +
209 +The directory of changing system settings: [Control Panel] -> [Date, Time, Language,and Regional Options] -> [Change the format of numbers, dates, and times]->[Customize]-> [List separator]. Please select [,] and export CSV file after setting.
210 +
211 +**Communication settings in HMI**
212 +
213 +Enable HMI Ethernet in [Project Settings];
214 +
215 +{{id name="I12.PLCProtocol_html_43b671f18153910d.png-5"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png||alt="12.PLC Protocol_html_43b671f18153910d.png" height="106" width="400"]]
216 +
217 +Set PLC IP in [Device IP] settings;
218 +
219 +{{id name="I12.PLCProtocol_html_27870d373581892e.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_10385ddd81c8baff.png||alt="12.PLC Protocol_html_27870d373581892e.png" height="206" width="600"]]
220 +
221 +**Cable Wiring**
222 +
223 +{{id name="I12.PLCProtocol_html_2297240b57346b2a.png-3"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="400"]]
224 +
176 176  == {{id name="HMicroLogix1200"/}}**MicroLogix 1200** ==
177 177  
178 178  The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200.
... ... @@ -318,7 +318,7 @@
318 318  [[image:Ethernet.png]]
319 319  
320 320  
321 -== **EtherNet/IP(CompactLogix Series)** ==
370 +== Rockwell EtherNet/IP(CompactLogix Series) ==
322 322  
323 323  Supported Series: Rockwell CompactLogix Series Ethernet
324 324  
... ... @@ -440,20 +440,11 @@
440 440  
441 441   **HMI Setting:**
442 442  
492 +① [Project]→[Communication]→[Setting]
443 443  
444 -**~ New project**
445 -
446 -1.[Home]→[New]→[New project]→Set the name,series and model of HMI→[Next]→[Screen style] →[OK].
447 -
448 -[[image:1727161664493-505.png]]
449 -
450 -**Communication configuration**
451 -
452 -1.[Project]→[Communication]→[Setting]
453 -
454 454  [[image:1726909065716-860.png]]
455 455  
456 -2.Choose protocol:
496 +Choose protocol:
457 457  
458 458   Device type [Rockwell]→[Rockwell EtherNet/IP(CompactLogix Series)]→[OK]
459 459  
... ... @@ -460,12 +460,12 @@
460 460  (% style="text-align:center" %)
461 461  [[image:1726909065723-657.png]]
462 462  
463 -3.[Setting]→[PLC IP Address]→[OK]→[Labels manage].
503 +[Setting]→[PLC IP Address]→[OK]→[Labels manage].
464 464  
465 465  (% style="text-align:center" %)
466 466  [[image:1726909065724-657.png]]
467 467  
468 -4.Tags import:
508 +Tags import:
469 469  
470 470  [Import Tags From File]→Choose the .CSV file→[Open]→[Save]→[OK]
471 471  
... ... @@ -472,4 +472,13 @@
472 472  (% style="text-align:center" %)
473 473  [[image:1726909065726-124.png]]
474 474  
475 -
515 +**Project making**
516 +
517 +①Using PIStudio to program a HMI project depending on the requirements.
518 +
519 +(% style="text-align:center" %)
520 +[[image:1726909065727-501.png]]
521 +
522 +②After programming[Compile], you can download the project into HMI when compilation complete.
523 +
524 +[[image:1726909065727-109.png]]
1727161664493-505.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Molly
Size
... ... @@ -1,1 +1,0 @@
1 -126.3 KB
Content