@@ -1,249 +1,0 @@ |
1 |
|
-= {{id name="HRockwell"/}}**Rockwell** = |
2 |
|
- |
3 |
|
-== {{id name="HDF1"/}}**DF1** == |
4 |
|
- |
5 |
|
-MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 |
6 |
|
- |
7 |
|
-**HMI Settings** |
8 |
|
- |
9 |
|
-|=Item|=Recommended |=Note |
10 |
|
-|=Protocol|Rockwell DF1| |
11 |
|
-|=Connection|RS232| |
12 |
|
-|=Baud rate|19200| |
13 |
|
-|=Stop bits|1| |
14 |
|
-|=Data bits|8| |
15 |
|
-|=Parity|None| |
16 |
|
-|=PLC Station No.|1| |
17 |
|
-|=HMI Station No.|0| |
18 |
|
- |
19 |
|
-**PLC Settings** |
20 |
|
- |
21 |
|
-DF1 Full Duplex protocol and CRC error check |
22 |
|
- |
23 |
|
-**Address List** |
24 |
|
- |
25 |
|
-|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note |
26 |
|
-|(% rowspan="5" %)Bit|I|I ddd.dd|0.0~~255.15|Only able to communicate with file number I1 |
27 |
|
-|O|O ddd.dd|0.0~~255.15|Only able to communicate with file number O0 |
28 |
|
-|B|B nnhh.dd|0.0~~ffff.15|Only able to communicate with file number B3 |
29 |
|
-|S|S ddd.dd|0.0~~255.15|Only able to communicate with file number S2 |
30 |
|
-|N|N nnhh.dd|0.0~~ffff.15|Only able to communicate with file number N7 |
31 |
|
-|(% rowspan="6" %)Word|S|S ddd|0~~255|Only able to communicate with file number S2 |
32 |
|
-|TS|TS nnhh|0~~ffff|Only able to communicate with file number T4 (Timer Preset Value) |
33 |
|
-|TP|TP nnhh|0~~ffff|Only able to communicate with file number T4 (Timer Accumulator Value) |
34 |
|
-|CS|CS nnhh|0~~ffff|Only able to communicate with file number C5 (Counter Preset Value) |
35 |
|
-|CP|CP nnhh|0~~ffff|Only able to communicate with file number C5 (Counter Accumulator Value) |
36 |
|
-|N|N nnhh|0~~ffff|Only able to communicate with file number N7 |
37 |
|
- |
38 |
|
-**Cable Wiring** |
39 |
|
- |
40 |
|
-{{id name="IAB.gif"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c884ca361be80135.gif||alt="AB.gif" height="247" width="400"]] |
41 |
|
- |
42 |
|
-== {{id name="HDF1Advanced"/}}**DF1 Advanced** == |
43 |
|
- |
44 |
|
-MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 |
45 |
|
- |
46 |
|
-**HMI Settings** |
47 |
|
- |
48 |
|
-|=Item|=Recommended |=Note |
49 |
|
-|=Protocol|Rockwell DF1 Advanced| |
50 |
|
-|=Connection|RS232| |
51 |
|
-|=Baud rate|19200| |
52 |
|
-|=Stop bits|1| |
53 |
|
-|=Data bits|8| |
54 |
|
-|=Parity|None| |
55 |
|
-|=PLC Station No.|1| |
56 |
|
-|=HMI Station No.|0| |
57 |
|
- |
58 |
|
-**PLC Settings** |
59 |
|
- |
60 |
|
-DF1 Full Duplex protocol and CRC error check |
61 |
|
- |
62 |
|
-**Address List** |
63 |
|
- |
64 |
|
-|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note |
65 |
|
-|(% rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1 |
66 |
|
-|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0 |
67 |
|
-|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2 |
68 |
|
-|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3 |
69 |
|
-|BN|BNddddd.dd|0.0~~99255.15|((( |
70 |
|
-Bit data file B0~~B99 |
71 |
|
- |
72 |
|
-First two digits is for file number |
73 |
|
- |
74 |
|
-For example, BN13001.00 represents file number B13, address 001, the 0th bit. |
75 |
|
-))) |
76 |
|
-|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7 |
77 |
|
-|NN|NNddddd.dd|0.0~~99255.15|((( |
78 |
|
-Integer data file bit format N0~~N99 |
79 |
|
- |
80 |
|
-First two digits is for file number |
81 |
|
- |
82 |
|
-For example, NN13001.00 represents file number N13, address 001, the 0th bit. |
83 |
|
-))) |
84 |
|
-|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2 |
85 |
|
-|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value) |
86 |
|
-|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value) |
87 |
|
-|TNS|TNSddddd|0~~99255|((( |
88 |
|
-Timer Preset Value |
89 |
|
- |
90 |
|
-First two digits is for file number |
91 |
|
- |
92 |
|
-For example, TNS99255 represents file number T99, address 255. |
93 |
|
-))) |
94 |
|
-|TNP|TNPddddd|0~~99255|((( |
95 |
|
-Timer Accumulator Value |
96 |
|
- |
97 |
|
-First two digits is for file number |
98 |
|
- |
99 |
|
-For example, TNP99255 represents file number T99, address 255. |
100 |
|
-))) |
101 |
|
-|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value) |
102 |
|
-|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value) |
103 |
|
-|CNS|CNSddddd|0~~99255|((( |
104 |
|
-Counter Preset Value |
105 |
|
- |
106 |
|
-First two digits is for file number |
107 |
|
- |
108 |
|
-For example, CNS99255 represents file number C99, address 255. |
109 |
|
-))) |
110 |
|
-|CNP|CNPddddd|0~~99255|((( |
111 |
|
-Counter Accumulator Value |
112 |
|
- |
113 |
|
-First two digits is for file number |
114 |
|
- |
115 |
|
-For example, CNP99255 represents file number C99, address 255. |
116 |
|
-))) |
117 |
|
-|N7|N7ddd|0~~255|Only able to communicate with file number N7 |
118 |
|
-|NN|NNddd|0~~99255|((( |
119 |
|
-Integer data file |
120 |
|
- |
121 |
|
-First two digits is for file number |
122 |
|
- |
123 |
|
-For example, NN99255 represents file number N99, address 255. |
124 |
|
-))) |
125 |
|
-|(% rowspan="3" %)Double Word|F8|F8ddd|0~~255|Only able to communicate with file number F8 |
126 |
|
-|FN|FNddddd|0~~99255|((( |
127 |
|
-Floating point data file |
128 |
|
- |
129 |
|
-First two digits is for file number |
130 |
|
- |
131 |
|
-For example, FN99255 represents file number F99, address 255. |
132 |
|
-))) |
133 |
|
-|LN|LNddddd|0~~99255|Long |
134 |
|
- |
135 |
|
-**Cable Wiring** |
136 |
|
- |
137 |
|
-{{id name="IAB.gif-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c884ca361be80135.gif||alt="AB.gif" height="247" width="400"]] |
138 |
|
- |
139 |
|
-== {{id name="HMicroLogix"/}}**MicroLogix** == |
140 |
|
- |
141 |
|
-MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 |
142 |
|
- |
143 |
|
-**HMI Settings** |
144 |
|
- |
145 |
|
-|**Item**|**Settings**|**Note** |
146 |
|
-|Protocol|Allen-Bradlley MicroLogix| |
147 |
|
-|Connection|RS232| |
148 |
|
-|Baud rate|19200| |
149 |
|
-|Data bit|8| |
150 |
|
-|Parity|None| |
151 |
|
-|Stop bit|1| |
152 |
|
-|PLC station No.|1| |
153 |
|
- |
154 |
|
-**Address List** |
155 |
|
- |
156 |
|
-|**Type**|**Device registers**|**Format**|**Range**|**Note** |
157 |
|
-|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| |
158 |
|
-|O|O d.d|0.0~~255.15| |
159 |
|
-|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) |
160 |
|
-|S|S d.d|0.0~~255.15| |
161 |
|
-|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) |
162 |
|
-|(% rowspan="9" %)Word|S|S d|0~~255| |
163 |
|
-|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) |
164 |
|
-|TP|TP nnhh|0~~ffff |
165 |
|
-|CS|CS nnhh|0~~ffff |
166 |
|
-|CP|CP nnhh|0~~ffff |
167 |
|
-|N|N nnhh|0~~ffff |
168 |
|
-|C|C nnhh|0~~ffff |
169 |
|
-|T|T nnhh|0~~ffff |
170 |
|
-|R|R nnhh|0~~ffff |
171 |
|
- |
172 |
|
-**Cable Wiring** |
173 |
|
- |
174 |
|
-{{id name="I12.PLCProtocol_html_58205bdf82c06d4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_32d8ab10ec374ea6.png||alt="12.PLC Protocol_html_58205bdf82c06d4.png" height="307" width="500"]] |
175 |
|
- |
176 |
|
-== {{id name="HEtherNet2FIP28CompactLogixSeries29"/}}**EtherNet/IP(CompactLogix Series)** == |
177 |
|
- |
178 |
|
-Allen-Brandly Compact Logix Free Tag |
179 |
|
- |
180 |
|
-**HMI Settings** |
181 |
|
- |
182 |
|
-|**Items**|**Settings**|**Note** |
183 |
|
-|Protocol|EtherNet/IP(CompactLogix Series)| |
184 |
|
-|Connection|Ethernet| |
185 |
|
-|Port No.|44818| |
186 |
|
- |
187 |
|
-**PLC Setting** |
188 |
|
- |
189 |
|
-Create new tags |
190 |
|
- |
191 |
|
-{{id name="I12.PLCProtocol_html_a748a27dcf7f1124.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_75d3f4097ac67d8e.png||alt="12.PLC Protocol_html_a748a27dcf7f1124.png" height="411" width="700"]] |
192 |
|
- |
193 |
|
-Export tags to CSV file. ([Tools] » [Export] » [Tags and Logic Comments]) |
194 |
|
- |
195 |
|
-{{id name="I12.PLCProtocol_html_151379170bb8ff3e.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_39bb299de26a0af0.png||alt="12.PLC Protocol_html_151379170bb8ff3e.png" height="352" width="700"]] |
196 |
|
- |
197 |
|
-Import labels, please open [Communication] window and click [Import label]; |
198 |
|
- |
199 |
|
-Select csv file, all tags will be displayed as belows; |
200 |
|
- |
201 |
|
-{{id name="I12.PLCProtocol_html_af192e54dee96f38.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4216defdc24cba39.png||alt="12.PLC Protocol_html_af192e54dee96f38.png" height="586" width="700"]] |
202 |
|
- |
203 |
|
-**✎Note:** |
204 |
|
- |
205 |
|
-Because in different region, the separation symbol is different, we suggest you check this before you want to import your tags. To open csv file as text format. |
206 |
|
- |
207 |
|
-{{id name="I12.PLCProtocol_html_33df1d63ebe53726.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_24f4d658173f88a9.png||alt="12.PLC Protocol_html_33df1d63ebe53726.png" height="206" width="700"]] |
208 |
|
- |
209 |
|
-The directory of changing system settings: [Control Panel] -> [Date, Time, Language,and Regional Options] -> [Change the format of numbers, dates, and times]->[Customize]-> [List separator]. Please select [,] and export CSV file after setting. |
210 |
|
- |
211 |
|
-**Communication settings in HMI** |
212 |
|
- |
213 |
|
-Enable HMI Ethernet in [Project Settings]; |
214 |
|
- |
215 |
|
-{{id name="I12.PLCProtocol_html_43b671f18153910d.png-5"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png||alt="12.PLC Protocol_html_43b671f18153910d.png" height="106" width="400"]] |
216 |
|
- |
217 |
|
-Set PLC IP in [Device IP] settings; |
218 |
|
- |
219 |
|
-{{id name="I12.PLCProtocol_html_27870d373581892e.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_10385ddd81c8baff.png||alt="12.PLC Protocol_html_27870d373581892e.png" height="206" width="600"]] |
220 |
|
- |
221 |
|
-**Cable Wiring** |
222 |
|
- |
223 |
|
-{{id name="I12.PLCProtocol_html_2297240b57346b2a.png-3"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="400"]] |
224 |
|
- |
225 |
|
-== {{id name="HMicroLogix1200"/}}**MicroLogix 1200** == |
226 |
|
- |
227 |
|
-The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200. |
228 |
|
- |
229 |
|
-* **Bit address I:** The address ranges from 0.0 to 255.15. The value of the data before the decimal point ranges from 0 to 255 (decimal). The value from 0 to 15 after the decimal point is the sub address (decimal). |
230 |
|
-* **Bit address B:** The address ranges from 000.0 to fff.15. The first f from left to right represents the block number (hexadecimal); The second and third f from left to right represent the word address (hexadecimal). The value 0 to 15 after the decimal point reprensents the sub address (decimal). |
231 |
|
-* **Word address S:** The word address ranges from 0 to 255 (decimal). |
232 |
|
-* **Word address TS:** The address ranges from 000.0 to ffff. The first and second f from left to right represents the block number (hexadecimal); The third and fourth f from left to right represent the word address (hexadecimal). |
233 |
|
- |
234 |
|
-**✎Note: **Register address TP, CS, CP, N, F and TS address edit are same. D indicates decimal, and F indicates hexadecimal. Different PLC models may support different registers. See the following table. |
235 |
|
- |
236 |
|
-|**PLC bit address type**|**Address format**|**Address range** |
237 |
|
-|I|dd.dd|I 0.0 ~~ 255.15 |
238 |
|
-|O|dd.dd|O 0.0 ~~ 255.15 |
239 |
|
-|B|fff.dd|B 000.0 ~~ fff.15 |
240 |
|
-|S|dd.dd|S 0.0 ~~ 255.15 |
241 |
|
-|N|ffff.dd|N 000.0 ~~ fff.15 |
242 |
|
-|**PLC word address type**|**Address format**|**Address range** |
243 |
|
-|S|ddd|S0 ~~ 255 |
244 |
|
-|TS|ffff|TS0 ~~ FFFF |
245 |
|
-|TP|ffff|TP0 ~~ FFFF |
246 |
|
-|CS|ffff|CS0 ~~ FFFF |
247 |
|
-|CP|ffff|CP0 ~~ FFFF |
248 |
|
-|N|ffff|N0 ~~ FFFF |
249 |
|
-|F|ffff|F0 ~~ FFFF |