... ... @@ -1,0 +1,1 @@ 1 +PIStudio.PLC Protocol.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Molly - Content
-
... ... @@ -247,3 +247,118 @@ 247 247 |CP|ffff|CP0 ~~ FFFF 248 248 |N|ffff|N0 ~~ FFFF 249 249 |F|ffff|F0 ~~ FFFF 250 + 251 +== **Ethernet/IP DF1** == 252 + 253 +Supported Series: Rockwell MicroLogix 1100, 1400, SLC5/05 Ethernet port. MicroLogix1000,1200,1500,SLC 5/03, 5/04 with 1761-NET-ENI 254 + 255 +|**Items**|**Settings**|**Note** 256 +|Protocol|Rock well Ethernet/IP DF1| 257 +|Connection|Ethernet| 258 +|Port No.|44818| 259 +|PLC station No.|1| 260 + 261 +**Address List** 262 + 263 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note 264 +|(% rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1 265 +|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0 266 +|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2 267 +|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3 268 +|BN|BNddddd.dd|0.0~~99255.15|((( 269 +Bit data file B0~~B99 270 + 271 +First two digits is for file number 272 + 273 +For example, BN13001.00 represents file number B13, address 001, the 0th bit. 274 +))) 275 +|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7 276 +|NN|NNddddd.dd|0.0~~99255.15|((( 277 +Integer data file bit format N0~~N99 278 + 279 +First two digits is for file number 280 + 281 +For example, NN13001.00 represents file number N13, address 001, the 0th bit. 282 +))) 283 +|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2 284 +|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value) 285 +|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value) 286 +|TNS|TNSddddd|0~~99255|((( 287 +Timer Preset Value 288 + 289 +First two digits is for file number 290 + 291 +For example, TNS99255 represents file number T99, address 255. 292 +))) 293 +|TNP|TNPddddd|0~~99255|((( 294 +Timer Accumulator Value 295 + 296 +First two digits is for file number 297 + 298 +For example, TNP99255 represents file number T99, address 255. 299 +))) 300 +|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value) 301 +|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value) 302 +|CNS|CNSddddd|0~~99255|((( 303 +Counter Preset Value 304 + 305 +First two digits is for file number 306 + 307 +For example, CNS99255 represents file number C99, address 255. 308 +))) 309 +|CNP|CNPddddd|0~~99255|((( 310 +Counter Accumulator Value 311 + 312 +First two digits is for file number 313 + 314 +For example, CNP99255 represents file number C99, address 255. 315 +))) 316 +|N7|N7ddd|0~~255|Only able to communicate with file number N7 317 +|NN|NNddd|0~~99255|((( 318 +Integer data file 319 + 320 +First two digits is for file number 321 + 322 +For example, NN99255 represents file number N99, address 255. 323 +))) 324 +|(% rowspan="3" %)Double Word|F8|F8ddd|0~~255|Only able to communicate with file number F8 325 +|FN|FNddddd|0~~99255|((( 326 +Floating point data file 327 + 328 +First two digits is for file number 329 + 330 +For example, FN99255 represents file number F99, address 255. 331 +))) 332 +|LN|LNddddd|0~~99255|Long 333 + 334 +**Cable Wiring** 335 + 336 +[[image:Ethernet.png]] 337 + 338 +**PLC Setting:** 339 + 340 +1.Open the RSLinx Classic Lite software and click [Configure Drivers...] in [Communications].[[image:1.png]] 341 + 342 +2.Click the drop-down menu and select EtherNet/IP driver[[image:2.png]] 343 + 344 +3.Click Add New and a pop-up window will pop up. Name the driver and click [OK] in the pop-up window.[[image:3.png]] 345 + 346 +4.The configuration driver window pops up., click on the correct network adapter option (such as the ASIX USB to Fast Ethernet Family Adapter option in this picture), and click OK[[image:4.png]] 347 + 348 +5.Click the [Close] button.[[image:5.png]] 349 + 350 +6.Click the [RSWho] button.[[image:6.png]] 351 + 352 +7.Pop up the RS Who window, indicating that the driver has been added successfully.[[image:7.png]] 353 + 354 +8.Open the RSLogix 500Pro software and select [System Comms...] in the [Comms option].[[image:8.jpg]] 355 + 356 +9.Select the driver you have created. All device nodes in the same LAN as the computer will be scanned. Select the PLC to be connected and click [OK]. 357 + 358 +[[image:9.png]] 359 + 360 +10.Click Comms [Go Online].[[image:10.png]] 361 + 362 +11.Click [YES] in the pop-up window.[[image:11.png]] 363 + 364 +12.Enter online mode.[[image:14.jpg]]
- 1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Molly - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.0 KB - Content
- 10.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Molly - Size
-
... ... @@ -1,0 +1,1 @@ 1 +112.1 KB - Content
- 11.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Molly - Size
-
... ... @@ -1,0 +1,1 @@ 1 +68.6 KB - Content
- 14.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Molly - Size
-
... ... @@ -1,0 +1,1 @@ 1 +70.0 KB - Content
- 2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Molly - Size
-
... ... @@ -1,0 +1,1 @@ 1 +32.2 KB - Content
- 3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Molly - Size
-
... ... @@ -1,0 +1,1 @@ 1 +39.2 KB - Content
- 4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Molly - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.5 KB - Content
- 5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Molly - Size
-
... ... @@ -1,0 +1,1 @@ 1 +25.0 KB - Content
- 6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Molly - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.0 KB - Content
- 7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Molly - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.7 KB - Content
- 8.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Molly - Size
-
... ... @@ -1,0 +1,1 @@ 1 +116.6 KB - Content
- 9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Molly - Size
-
... ... @@ -1,0 +1,1 @@ 1 +74.5 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_10385ddd81c8baff.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.5 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_4216defdc24cba39.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +28.5 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_75d3f4097ac67d8e.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +195.6 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.1 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_c884ca361be80135.gif
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Hunter - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.0 KB - Content
- XWiki.XWikiComments[0]
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.VZ - Comment
-
... ... @@ -1,0 +1,2 @@ 1 +I have a 3070ig-O-RS v1.7 HMI panel. 2 +I tried it with an Allen-Bradley Micro820 2080-LC20-20QWB V12 PLC with Ethernet connection, with more different Rockwell protocols (for example Micro850 Ethernet (Free Tags) too). But when I am exporting the PLC TAGs (variables) from Connected Components Workbench (CCW) to a CSV or TXT files, and I am importing these into the PIStudio, an Error message comes in the PIStudio: "Wrong File Format". (???) Please, if anyone can help! - Date
-
... ... @@ -1,0 +1,1 @@ 1 +2024-08-26 18:34:39.437
- XWiki.XWikiComments[1]
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.VZ - Comment
-
... ... @@ -1,0 +1,4 @@ 1 +I imported already successfully the Allen-Bradley Micro PLC's Tags CSV file into the PIStudio 3070ig project (I edited it manually). But on the 3070ig-O-RS V1.7 HMI comes the next message: 2 +"This model does not support Free Tags!" ??? 3 +What could be the problem? This 3070ig type HMI doesn't support this? Maybe I should update the firmware? 4 +Please, if anyone can help! - Date
-
... ... @@ -1,0 +1,1 @@ 1 +2024-09-06 21:58:06.713