2.1 | 1 | = {{id name="HRockwell"/}}**Rockwell** = |
2 | |||
3 | == {{id name="HDF1"/}}**DF1** == | ||
4 | |||
5 | MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 | ||
6 | |||
7 | **HMI Settings** | ||
8 | |||
9 | |=Item|=Recommended |=Note | ||
10 | |=Protocol|Rockwell DF1| | ||
11 | |=Connection|RS232| | ||
12 | |=Baud rate|19200| | ||
13 | |=Stop bits|1| | ||
14 | |=Data bits|8| | ||
15 | |=Parity|None| | ||
16 | |=PLC Station No.|1| | ||
17 | |=HMI Station No.|0| | ||
18 | |||
19 | **PLC Settings** | ||
20 | |||
21 | DF1 Full Duplex protocol and CRC error check | ||
22 | |||
23 | **Address List** | ||
24 | |||
25 | |=**Type**|=**Device registers**|=**Format**|=**Range**|=Note | ||
26 | |(% rowspan="5" %)Bit|I|I ddd.dd|0.0~~255.15|Only able to communicate with file number I1 | ||
27 | |O|O ddd.dd|0.0~~255.15|Only able to communicate with file number O0 | ||
28 | |B|B nnhh.dd|0.0~~ffff.15|Only able to communicate with file number B3 | ||
29 | |S|S ddd.dd|0.0~~255.15|Only able to communicate with file number S2 | ||
30 | |N|N nnhh.dd|0.0~~ffff.15|Only able to communicate with file number N7 | ||
31 | |(% rowspan="6" %)Word|S|S ddd|0~~255|Only able to communicate with file number S2 | ||
32 | |TS|TS nnhh|0~~ffff|Only able to communicate with file number T4 (Timer Preset Value) | ||
33 | |TP|TP nnhh|0~~ffff|Only able to communicate with file number T4 (Timer Accumulator Value) | ||
34 | |CS|CS nnhh|0~~ffff|Only able to communicate with file number C5 (Counter Preset Value) | ||
35 | |CP|CP nnhh|0~~ffff|Only able to communicate with file number C5 (Counter Accumulator Value) | ||
36 | |N|N nnhh|0~~ffff|Only able to communicate with file number N7 | ||
37 | |||
38 | **Cable Wiring** | ||
39 | |||
40 | {{id name="IAB.gif"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c884ca361be80135.gif||alt="AB.gif" height="247" width="400"]] | ||
41 | |||
42 | == {{id name="HDF1Advanced"/}}**DF1 Advanced** == | ||
43 | |||
44 | MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5 | ||
45 | |||
46 | **HMI Settings** | ||
47 | |||
48 | |=Item|=Recommended |=Note | ||
49 | |=Protocol|Rockwell DF1 Advanced| | ||
50 | |=Connection|RS232| | ||
51 | |=Baud rate|19200| | ||
52 | |=Stop bits|1| | ||
53 | |=Data bits|8| | ||
54 | |=Parity|None| | ||
55 | |=PLC Station No.|1| | ||
56 | |=HMI Station No.|0| | ||
57 | |||
58 | **PLC Settings** | ||
59 | |||
60 | DF1 Full Duplex protocol and CRC error check | ||
61 | |||
62 | **Address List** | ||
63 | |||
64 | |=**Type**|=**Device registers**|=**Format**|=**Range**|=Note | ||
65 | |(% rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1 | ||
66 | |O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0 | ||
67 | |S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2 | ||
68 | |B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3 | ||
69 | |BN|BNddddd.dd|0.0~~99255.15|((( | ||
70 | Bit data file B0~~B99 | ||
71 | |||
72 | First two digits is for file number | ||
73 | |||
74 | For example, BN13001.00 represents file number B13, address 001, the 0th bit. | ||
75 | ))) | ||
76 | |N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7 | ||
77 | |NN|NNddddd.dd|0.0~~99255.15|((( | ||
78 | Integer data file bit format N0~~N99 | ||
79 | |||
80 | First two digits is for file number | ||
81 | |||
82 | For example, NN13001.00 represents file number N13, address 001, the 0th bit. | ||
83 | ))) | ||
84 | |(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2 | ||
85 | |T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value) | ||
86 | |T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value) | ||
87 | |TNS|TNSddddd|0~~99255|((( | ||
88 | Timer Preset Value | ||
89 | |||
90 | First two digits is for file number | ||
91 | |||
92 | For example, TNS99255 represents file number T99, address 255. | ||
93 | ))) | ||
94 | |TNP|TNPddddd|0~~99255|((( | ||
95 | Timer Accumulator Value | ||
96 | |||
97 | First two digits is for file number | ||
98 | |||
99 | For example, TNP99255 represents file number T99, address 255. | ||
100 | ))) | ||
101 | |C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value) | ||
102 | |C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value) | ||
103 | |CNS|CNSddddd|0~~99255|((( | ||
104 | Counter Preset Value | ||
105 | |||
106 | First two digits is for file number | ||
107 | |||
108 | For example, CNS99255 represents file number C99, address 255. | ||
109 | ))) | ||
110 | |CNP|CNPddddd|0~~99255|((( | ||
111 | Counter Accumulator Value | ||
112 | |||
113 | First two digits is for file number | ||
114 | |||
115 | For example, CNP99255 represents file number C99, address 255. | ||
116 | ))) | ||
117 | |N7|N7ddd|0~~255|Only able to communicate with file number N7 | ||
118 | |NN|NNddd|0~~99255|((( | ||
119 | Integer data file | ||
120 | |||
121 | First two digits is for file number | ||
122 | |||
123 | For example, NN99255 represents file number N99, address 255. | ||
124 | ))) | ||
125 | |(% rowspan="3" %)Double Word|F8|F8ddd|0~~255|Only able to communicate with file number F8 | ||
126 | |FN|FNddddd|0~~99255|((( | ||
127 | Floating point data file | ||
128 | |||
129 | First two digits is for file number | ||
130 | |||
131 | For example, FN99255 represents file number F99, address 255. | ||
132 | ))) | ||
133 | |LN|LNddddd|0~~99255|Long | ||
134 | |||
135 | **Cable Wiring** | ||
136 | |||
137 | {{id name="IAB.gif-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c884ca361be80135.gif||alt="AB.gif" height="247" width="400"]] | ||
138 | |||
139 | == {{id name="HMicroLogix"/}}**MicroLogix** == | ||
140 | |||
141 | MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 | ||
142 | |||
143 | **HMI Settings** | ||
144 | |||
145 | |**Item**|**Settings**|**Note** | ||
146 | |Protocol|Allen-Bradlley MicroLogix| | ||
147 | |Connection|RS232| | ||
148 | |Baud rate|19200| | ||
149 | |Data bit|8| | ||
150 | |Parity|None| | ||
151 | |Stop bit|1| | ||
152 | |PLC station No.|1| | ||
153 | |||
154 | **Address List** | ||
155 | |||
156 | |**Type**|**Device registers**|**Format**|**Range**|**Note** | ||
157 | |(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| | ||
158 | |O|O d.d|0.0~~255.15| | ||
159 | |B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) | ||
160 | |S|S d.d|0.0~~255.15| | ||
161 | |N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) | ||
162 | |(% rowspan="9" %)Word|S|S d|0~~255| | ||
163 | |TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) | ||
164 | |TP|TP nnhh|0~~ffff | ||
165 | |CS|CS nnhh|0~~ffff | ||
166 | |CP|CP nnhh|0~~ffff | ||
167 | |N|N nnhh|0~~ffff | ||
168 | |C|C nnhh|0~~ffff | ||
169 | |T|T nnhh|0~~ffff | ||
170 | |R|R nnhh|0~~ffff | ||
171 | |||
172 | **Cable Wiring** | ||
173 | |||
174 | {{id name="I12.PLCProtocol_html_58205bdf82c06d4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_32d8ab10ec374ea6.png||alt="12.PLC Protocol_html_58205bdf82c06d4.png" height="307" width="500"]] | ||
175 | |||
176 | == {{id name="HEtherNet2FIP28CompactLogixSeries29"/}}**EtherNet/IP(CompactLogix Series)** == | ||
177 | |||
178 | Allen-Brandly Compact Logix Free Tag | ||
179 | |||
180 | **HMI Settings** | ||
181 | |||
182 | |**Items**|**Settings**|**Note** | ||
183 | |Protocol|EtherNet/IP(CompactLogix Series)| | ||
184 | |Connection|Ethernet| | ||
185 | |Port No.|44818| | ||
186 | |||
187 | **PLC Setting** | ||
188 | |||
189 | Create new tags | ||
190 | |||
191 | {{id name="I12.PLCProtocol_html_a748a27dcf7f1124.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_75d3f4097ac67d8e.png||alt="12.PLC Protocol_html_a748a27dcf7f1124.png" height="411" width="700"]] | ||
192 | |||
193 | Export tags to CSV file. ([Tools] » [Export] » [Tags and Logic Comments]) | ||
194 | |||
195 | {{id name="I12.PLCProtocol_html_151379170bb8ff3e.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_39bb299de26a0af0.png||alt="12.PLC Protocol_html_151379170bb8ff3e.png" height="352" width="700"]] | ||
196 | |||
197 | Import labels, please open [Communication] window and click [Import label]; | ||
198 | |||
199 | Select csv file, all tags will be displayed as belows; | ||
200 | |||
201 | {{id name="I12.PLCProtocol_html_af192e54dee96f38.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_4216defdc24cba39.png||alt="12.PLC Protocol_html_af192e54dee96f38.png" height="586" width="700"]] | ||
202 | |||
203 | **✎Note:** | ||
204 | |||
205 | Because in different region, the separation symbol is different, we suggest you check this before you want to import your tags. To open csv file as text format. | ||
206 | |||
207 | {{id name="I12.PLCProtocol_html_33df1d63ebe53726.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_24f4d658173f88a9.png||alt="12.PLC Protocol_html_33df1d63ebe53726.png" height="206" width="700"]] | ||
208 | |||
209 | The directory of changing system settings: [Control Panel] -> [Date, Time, Language,and Regional Options] -> [Change the format of numbers, dates, and times]->[Customize]-> [List separator]. Please select [,] and export CSV file after setting. | ||
210 | |||
211 | **Communication settings in HMI** | ||
212 | |||
213 | Enable HMI Ethernet in [Project Settings]; | ||
214 | |||
215 | {{id name="I12.PLCProtocol_html_43b671f18153910d.png-5"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_a98ee09dac36eba3.png||alt="12.PLC Protocol_html_43b671f18153910d.png" height="106" width="400"]] | ||
216 | |||
217 | Set PLC IP in [Device IP] settings; | ||
218 | |||
219 | {{id name="I12.PLCProtocol_html_27870d373581892e.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_10385ddd81c8baff.png||alt="12.PLC Protocol_html_27870d373581892e.png" height="206" width="600"]] | ||
220 | |||
221 | **Cable Wiring** | ||
222 | |||
223 | {{id name="I12.PLCProtocol_html_2297240b57346b2a.png-3"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ac8ece9a26719fda.png||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="400"]] | ||
224 | |||
225 | == {{id name="HMicroLogix1200"/}}**MicroLogix 1200** == | ||
226 | |||
227 | The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200. | ||
228 | |||
229 | * **Bit address I:** The address ranges from 0.0 to 255.15. The value of the data before the decimal point ranges from 0 to 255 (decimal). The value from 0 to 15 after the decimal point is the sub address (decimal). | ||
230 | * **Bit address B:** The address ranges from 000.0 to fff.15. The first f from left to right represents the block number (hexadecimal); The second and third f from left to right represent the word address (hexadecimal). The value 0 to 15 after the decimal point reprensents the sub address (decimal). | ||
231 | * **Word address S:** The word address ranges from 0 to 255 (decimal). | ||
232 | * **Word address TS:** The address ranges from 000.0 to ffff. The first and second f from left to right represents the block number (hexadecimal); The third and fourth f from left to right represent the word address (hexadecimal). | ||
233 | |||
234 | **✎Note: **Register address TP, CS, CP, N, F and TS address edit are same. D indicates decimal, and F indicates hexadecimal. Different PLC models may support different registers. See the following table. | ||
235 | |||
236 | |**PLC bit address type**|**Address format**|**Address range** | ||
237 | |I|dd.dd|I 0.0 ~~ 255.15 | ||
238 | |O|dd.dd|O 0.0 ~~ 255.15 | ||
239 | |B|fff.dd|B 000.0 ~~ fff.15 | ||
240 | |S|dd.dd|S 0.0 ~~ 255.15 | ||
241 | |N|ffff.dd|N 000.0 ~~ fff.15 | ||
242 | |**PLC word address type**|**Address format**|**Address range** | ||
243 | |S|ddd|S0 ~~ 255 | ||
244 | |TS|ffff|TS0 ~~ FFFF | ||
245 | |TP|ffff|TP0 ~~ FFFF | ||
246 | |CS|ffff|CS0 ~~ FFFF | ||
247 | |CP|ffff|CP0 ~~ FFFF | ||
248 | |N|ffff|N0 ~~ FFFF | ||
249 | |F|ffff|F0 ~~ FFFF | ||
![]() |
12.1 | 250 | |
![]() |
13.1 | 251 | == **Ethernet/IP DF1** == |
![]() |