1 += {{id name="HSHIMADEN"/}}**SHIMADEN** =
2 +
3 +== {{id name="HFP23Series"/}}**FP23 Series** ==
4 +
5 +Supported series: SHIMADEN FP23 series
6 +
7 +**HMI Setting**
8 +
9 +|**Items**|**Settings**|**Note**
10 +|Protocol|SHIMADEN FP23 series|
11 +|Connection|RS485 (9600, 1, 7, EVEN)|
12 +|Port No.|None|
13 +|PLC station No.|0|
14 +
15 +**Address List**
16 +
17 +|**Device address**|**HMI register**|**Address range**|**Type**
18 +|0040-0043(HEX)|FP040|100064-200067|Read only
19 +|0100-010B(HEX)|FP100|100256-200267|Read only
20 +|0110-0142(HEX)|FP110|100272-200322|Read only
21 +|0182-0252(HEX)|FP182|100386-200594|Write only
22 +|0280-0281(HEX)|FP280|100640-200641|Read only
23 +|0300-030B(HEX)|FP300|100768-200779|Read and write
24 +|0380-039F(HEX)|FP380|100896-200927|Read and write
25 +|0400-04D7(HEX)|FP400|101024-201239|Read and write
26 +|0500-05B0(HEX)|FP500|101280-201456|Read and write
27 +|0600-0670(HEX)|FP600|101536-201814|Read and write
28 +|0720-0738(HEX)|FP720|101824-201848|Read and write
29 +|0800-083F(HEX)|FP800|102048-202111|Read and write
30 +|0900-0952(HEX)|FP900|102304-202386|Read and write
31 +| |Ctrl|0-2|
32 +
33 +**✎Note:**
34 +
35 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
36 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in FP23;
37 +* The Ctrl register is used to store the control group number and BCC check mode.
38 +
39 +**Ctrl Register Description**
40 +
41 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
42 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR .
43 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
44 +* Ctrl3 reserved
45 +
46 +**✎Note:**
47 +
48 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
49 +
50 +**Cable Wiring**
51 +
52 +{{id name="I12.PLCProtocol_html_5e9a81a14106da9e.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_7b2556c42d43a768.png||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
53 +
54 +{{id name="I12.PLCProtocol_html_1897d92be6948d58.png-2"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c6d16b5adff76549.png||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
55 +
56 +**✎Note:** COM3 only available in PI8000/PI9000 series.
57 +
58 +== {{id name="HSR90"/}}**SR90** ==
59 +
60 +Supported series: SHIMADEN SR90 series
61 +
62 +**HMI Setting**
63 +
64 +|**Items**|**Settings**|**Note**
65 +|Protocol|SHIMADEN SR90|
66 +|Connection|RS485 (1200, 1, 7, EVEN)|
67 +|Port No.|None|
68 +|PLC station No.|0|
69 +
70 +**Address List**
71 +
72 +|**Device address**|**HMI register**|**Address range**|**Type**
73 +|0040-0043 (HEX)|SR040|100064-100067|Read only
74 +|0100-010A(HEX)|SR0100|100256-100266|Read only
75 +|0182-018C(HEX)|SR0182|100386-100396|Write only
76 +|0300-04FE(HEX)|SR0300|100768-101278|Write/read
77 +|0500-050B(HEX)|SR0500|101280-101291|Write/read
78 +|0590-0611(HEX)|SR0590|101424-101553|Write/read
79 +|0701-0709(HEX)|SR0701|101793-101801|Write/read
80 +| |Ctrl|0-2|~-~-
81 +
82 +**✎Note:**
83 +
84 +* The upper 2 bits of the address of HMIs are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
85 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in SR90;
86 +* The Ctrl register is used to store the control group number and BCC check mode. See how to use it below;
87 +
88 +**Ctrl Register Description**
89 +
90 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
91 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR , STX_ETX_CR LF and @_:_CR .
92 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
93 +* Ctrl3 reserved
94 +
95 +**✎Note:**
96 +
97 +After reloading the HMI project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
98 +
99 +**Cable Wiring**
100 +
101 +{{id name="I12.PLCProtocol_html_5e9a81a14106da9e.png-2"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_7b2556c42d43a768.png||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
102 +
103 +{{id name="I12.PLCProtocol_html_1897d92be6948d58.png-3"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c6d16b5adff76549.png||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
104 +
105 +**✎Note:** COM3 only available in PI8000/PI9000 series.
106 +
107 +== {{id name="HMR13Series28Standard29"/}}**MR13 Series(Standard)** ==
108 +
109 +Supported series: SHIMADEN MR13 series
110 +
111 +**HMI Setting**
112 +
113 +|**Items**|**Settings**|**Note**
114 +|Protocol|SHIMADEN standard protocol|
115 +|Connection|RS485 (1200, 1, 7, EVEN)|
116 +|Port No.|None|
117 +|PLC station No.|0|
118 +
119 +**Address List**
120 +
121 +|**Device address**|**HMI register**|**Address range**|**Type**
122 +|0100-010B(HEX)|MR100|100256-300267|Read only
123 +|0111-0126(HEX)|MR111|100273-300294|Read only
124 +|0184-0192(HEX)|MR184|100388-300402|Write only
125 +|0280-0282(HEX)|MR280|100640-300642|Read only
126 +|0300-030B(HEX)|MR300|100768-300779|Read/write
127 +|0314-0317(HEX)|MR314|100788-300791|Read/write
128 +|031A(HEX)|MR31A|100794-300794|Read/write
129 +|0320-0321(HEX)|MR320|100800-300801|Read/write
130 +|0400-0504(HEX)|MR400|101024-301284|Read/write
131 +|0506(HEX)|MR506|101286-301286|Read/write
132 +|0510-0514(HEX)|MR510|101296-301300|Read/write
133 +|0516-0524(HEX)|MR516|101302-301316|Read/write
134 +|0526(HEX)|MR526|101318-301318|Read/write
135 +|0580-08C3(HEX)|MR580|101408-302243|Read/write
136 +|~-~-|Ctrl|0-2|~-~-
137 +
138 +**✎Note:**
139 +
140 +* The upper 2 bits of the address of the HMI register are taken as the sub address, and the real address is the last four bits (for example, if the address is 100256, then 10 is the sub address as 1, and 0256 is the real address);
141 +* The address range in the table is only divided by the start and end addresses, and some of the addresses in the range have no corresponding address in MR13;
142 +* The Ctrl register is used to store the control group number and BCC check mode.
143 +
144 +**Ctrl Register Description**
145 +
146 +* The Ctrl register is a special register that does not communicate with the temperature controller. User needs to assign value in the screen according to the settings as in the temperature controller.
147 +* Ctrl0 indicates the setting of the control character, the valid values are 1, 2, 3 respectively, and the corresponding control group is: STX_ETX_CR, STX_ETX_CR LF and @_:_CR .
148 +* Ctrl1 indicates the BCC block check mode. The valid value range is 1-4. The corresponding check mode is: 1.ADD, 2.ADD_two's cmp, 3.XOR, 4.None;
149 +* Ctrl3 reserved
150 +
151 +**✎Note:**
152 +
153 +After reloading project or restarting the HMI, HMI will reset the value of ctrl0 and ctrl1 as 1, so user need to set these two values to make it the same as it in the temperature controller, then communication will be normal.
154 +
155 +**Cable Wiring**
156 +
157 +{{id name="I12.PLCProtocol_html_5e9a81a14106da9e.png-3"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_7b2556c42d43a768.png||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
158 +
159 +{{id name="I12.PLCProtocol_html_1897d92be6948d58.png-4"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c6d16b5adff76549.png||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
160 +
161 +**✎Note:** COM3 only available in PI8000/PI9000 series.