@@ -1,0 +1,341 @@ |
|
1 |
+= {{id name="HWECON"/}}WECON = |
|
2 |
+ |
|
3 |
+== {{id name="HLX3Series"/}}**LX3 Series** == |
|
4 |
+ |
|
5 |
+Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM |
|
6 |
+ |
|
7 |
+**HMI Settings** |
|
8 |
+ |
|
9 |
+|=**Item**|=**Settings**|=**Note** |
|
10 |
+|=Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| |
|
11 |
+|=Connection|RS422/RS485| |
|
12 |
+|=Baud rate|9600| |
|
13 |
+|=Data bit|7| |
|
14 |
+|=Parity|EVEN| |
|
15 |
+|=Stop bit|1| |
|
16 |
+|=PLC station No.|1| |
|
17 |
+ |
|
18 |
+**Address List** |
|
19 |
+ |
|
20 |
+|=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** |
|
21 |
+|=Bit|=X|X|Xo|0~~303237| |
|
22 |
+|=Y|Y|Y o|0~~303237| |
|
23 |
+|=M|M|M d|0~~99999| |
|
24 |
+|=T|T|T d|0~~99999| |
|
25 |
+|=C|C|C d|0~~99999| |
|
26 |
+|=S|S|S d|0~~99999| |
|
27 |
+|=Word|=X|X|Xo|0~~303237| |
|
28 |
+|=Y|Y|Y o|0~~303237| |
|
29 |
+|=M|M|M d|0~~99999| |
|
30 |
+|=T|T|T d|0~~99999| |
|
31 |
+|=C|C|C d|0~~199| |
|
32 |
+|=D|D|D d|0~~7999| |
|
33 |
+|=S|S|S d|0~~99999| |
|
34 |
+|=SD|SD|SD d|8000~~9999| |
|
35 |
+ |
|
36 |
+**Cable Wiring** |
|
37 |
+ |
|
38 |
+* **RS485** |
|
39 |
+ |
|
40 |
+{{id name="I12.PLCProtocol_html_1897d92be6948d58.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c6d16b5adff76549.png||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]] |
|
41 |
+ |
|
42 |
+* **RS422** |
|
43 |
+ |
|
44 |
+{{id name="I12.PLCProtocol_html_5c7fca9a70da2ee8.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_59ce051d2c5e70e0.png||alt="12.PLC Protocol_html_5c7fca9a70da2ee8.png" height="247" width="389"]] |
|
45 |
+ |
|
46 |
+**✎Note:** |
|
47 |
+ |
|
48 |
+* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) . |
|
49 |
+* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual. |
|
50 |
+ |
|
51 |
+[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] |
|
52 |
+ |
|
53 |
+{{id name="HHMIsettings"/}}**HMI settings** |
|
54 |
+ |
|
55 |
+**Download PIStudio Software** |
|
56 |
+ |
|
57 |
+Please visit the link below to get the latest version PIstudio for HMI programming: |
|
58 |
+ |
|
59 |
+* [[Download link>>url:https://docs.we-con.com.cn/bin/view/PIStudio/Download/3%20Software/]] |
|
60 |
+ |
|
61 |
+**Create a new HMI project connect with PLC** |
|
62 |
+ |
|
63 |
+Check the link below for the video to show you how to get started with a new project |
|
64 |
+ |
|
65 |
+* [[Video>>url:https://youtu.be/0FpmDZe_8U8]] |
|
66 |
+ |
|
67 |
+For more videos, please visit our Youtube channel: [[http:~~/~~/www.youtube.com/user/Wecon2004/videos>>url:http://www.youtube.com/user/Wecon2004/videos]] |
|
68 |
+ |
|
69 |
+**General** |
|
70 |
+ |
|
71 |
+HMI could communicate with PLC and support many PLC protocols. It is easy to operate and set communication parameters. This demo shows how to make a communication with PLC device, use WECON LX3V Series PLC as an example. |
|
72 |
+ |
|
73 |
+**Protocol settings** |
|
74 |
+ |
|
75 |
+The communication between two devices requires a protocol. The following contents show the steps of protocol settings. |
|
76 |
+ |
|
77 |
+Please select the protocol, when creating a new project. |
|
78 |
+ |
|
79 |
+1. Select the COM port for communication; |
|
80 |
+1. PLC type: It means PLC brand, like WECON; |
|
81 |
+1. PLC model: It shows the model of PLC, such as LX3V; |
|
82 |
+ |
|
83 |
+{{id name="Iimage-20220819093729-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_271ccf1461ff2285.png||alt="image-20220819093729-1.png" height="236" width="464"]] |
|
84 |
+ |
|
85 |
+If you want to change the protocol for existing project, please click [Program] → [Communication] to open the [Communication] windows, shown as the following figure. |
|
86 |
+ |
|
87 |
+{{id name="Iimage-20220819093729-2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_9089051384ca99de.png||alt="image-20220819093729-2.png" height="138" width="702"]] |
|
88 |
+ |
|
89 |
+The steps to change the protocol for project are as follows. |
|
90 |
+ |
|
91 |
+1. Click [Setting] to open the [Communication device] window; |
|
92 |
+1. Select communication port, such as COM1; |
|
93 |
+1. Select Serial port for communication, such as RS422; |
|
94 |
+1. Select device type (device brand), such as WECON; |
|
95 |
+1. Select the protocol for communication, such as WECON LX3V; |
|
96 |
+ |
|
97 |
+{{id name="Iimage-20220819093729-3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_33df6370c17ebfa9.png||alt="image-20220819093729-3.png" height="674" width="875"]] |
|
98 |
+ |
|
99 |
+**Parameter settings** |
|
100 |
+ |
|
101 |
+The parameters settings are in [Communication] window, shown as following below. |
|
102 |
+ |
|
103 |
+1. Click [Setting] to open the [COM port setting] window; |
|
104 |
+1. Set the parameters such as [connection], [Baud rate] and so on; |
|
105 |
+ |
|
106 |
+{{id name="Iimage-20220819093729-4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_891cd58628495097.png||alt="image-20220819093729-4.png" height="636" width="818"]] |
|
107 |
+ |
|
108 |
+1. Click [Setting] to open [Timeout] setting window, you could set the parameters according your requirements, or just use the default value. |
|
109 |
+ |
|
110 |
+{{id name="Iimage-20220819093729-5.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_b80c1a7329ce3f5f.png||alt="image-20220819093729-5.png" height="296" width="349"]] |
|
111 |
+ |
|
112 |
+**Set PLC address in HMI screen** |
|
113 |
+ |
|
114 |
+1. Place the objects to HMI screen; |
|
115 |
+1. Double-click the object to open the setting window; |
|
116 |
+1. Click “Edit” to open the address setting windows; |
|
117 |
+1. Connection: select the serial port in HMI; |
|
118 |
+1. Address type: All the PLC address types will be display in this list, such as M; |
|
119 |
+1. Address No.: Please input the number of this address, such as 0; |
|
120 |
+ |
|
121 |
+{{id name="Iimage-20220819093729-6.jpeg"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_c233137c112020bf.jpg||alt="image-20220819093729-6.jpeg" height="817" width="1593"]] |
|
122 |
+ |
|
123 |
+**HMI Compilation Download** |
|
124 |
+ |
|
125 |
+{{id name="Iimage-20220902171247-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_49085bc4fc23af93.png||alt="image-20220902171247-1.png" height="1078" width="1262"]] |
|
126 |
+ |
|
127 |
+**Communication cable** |
|
128 |
+ |
|
129 |
+In order to ensure the stability of communication, please use the twisted-pair communication cable with good grounding. The following figure shows the pin out definition. |
|
130 |
+ |
|
131 |
+{{id name="Iimage-20220819093729-7.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_e18a02a8b5c24f4a.png||alt="image-20220819093729-7.png" height="256" width="414"]] |
|
132 |
+ |
|
133 |
+**HMI communication PLC use Modbus ** |
|
134 |
+ |
|
135 |
+* HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>url:https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]] |
|
136 |
+* PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]] |
|
137 |
+ |
|
138 |
+{{id name="HPLCsettings"/}}**PLC settings** |
|
139 |
+ |
|
140 |
+**Download PLC Software** |
|
141 |
+ |
|
142 |
+Please visit below link to get the latest version PLC Editor for HMI programming |
|
143 |
+ |
|
144 |
+* LX3V:[[Download link>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor/10%20Hardware%20/Software/]] |
|
145 |
+* LX5V:[[Download link>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/Download/03%20Software/]] |
|
146 |
+ |
|
147 |
+**Start a new PLC project** |
|
148 |
+ |
|
149 |
+Start a new PLC project by clicking “New” on the left top corner of screen, select the PLC mode from the drop-down list. |
|
150 |
+ |
|
151 |
+{{id name="Iimage-20220819101447-3.jpeg"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d5d194db9d1d33d0.jpg||alt="image-20220819101447-3.jpeg" height="411" width="726"]] |
|
152 |
+ |
|
153 |
+**Add a new instruction ** |
|
154 |
+ |
|
155 |
+Double click on the ladder, select the ladder symbol (instruction) from the drop-down list, then enter the address for this symbol. |
|
156 |
+ |
|
157 |
+{{id name="Iimage-20220819105530-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_6e59dd6d3eba4d.png||alt="image-20220819105530-1.png" height="387" width="698"]] |
|
158 |
+ |
|
159 |
+You could also select the ladder symbol from the menu bar directly. |
|
160 |
+ |
|
161 |
+{{id name="Iimage-20220819093729-12.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_db5a3ad72966c00e.png||alt="image-20220819093729-12.png" height="1040" width="1920"]] |
|
162 |
+ |
|
163 |
+**Add comment to PLC program** |
|
164 |
+ |
|
165 |
+{{id name="Iimage-20220819105630-3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_50fcec6a5d6ac220.png||alt="image-20220819105630-3.png" height="413" width="698"]] |
|
166 |
+ |
|
167 |
+**Add the statement to PLC program** |
|
168 |
+ |
|
169 |
+Add the statement by single click on “Statement”, when finished, single click on “Statement” again to go back to Ladder edit. |
|
170 |
+ |
|
171 |
+{{id name="Iimage-20220819105644-4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d44e5ea0b00e2e14.png||alt="image-20220819105644-4.png" height="345" width="698"]] |
|
172 |
+ |
|
173 |
+**Compile ** |
|
174 |
+ |
|
175 |
+You need to compile the PLC program before downloading or running Off-line simulator. The background color will be changed from purple to white when there is no error. |
|
176 |
+ |
|
177 |
+{{id name="Iimage-20220819093729-15.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_e2d51171f234946a.png||alt="image-20220819093729-15.png" height="356" width="1912"]] |
|
178 |
+ |
|
179 |
+**Download setting ** |
|
180 |
+ |
|
181 |
+Click on “Transfer Setup” to select download mode. |
|
182 |
+ |
|
183 |
+{{id name="Iimage-20220820150853-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_98b1686a16c575ea.png||alt="image-20220820150853-1.png" height="713" width="1509"]] **Download PLC program to PLC** |
|
184 |
+ |
|
185 |
+Quick select the parameters and main program of PLC program, then download to PLC, “Yes”-”Yes”-”OK” |
|
186 |
+ |
|
187 |
+{{id name="Iimage-20220819093729-17.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_575b66f5b3d8cac5.png||alt="image-20220819093729-17.png" height="808" width="1920"]] |
|
188 |
+ |
|
189 |
+**Upload PLC program from PLC** |
|
190 |
+ |
|
191 |
+Read the PLC program from PLC to computer. |
|
192 |
+ |
|
193 |
+{{id name="Iimage-20220819093729-18.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_66ea9f304121cf6d.png||alt="image-20220819093729-18.png" height="762" width="1920"]] |
|
194 |
+ |
|
195 |
+**Device monitor** |
|
196 |
+ |
|
197 |
+Monitor the value of certain address in PLC, double click “Current value” to change the value in this address. |
|
198 |
+ |
|
199 |
+{{id name="Iimage-20220819093730-19.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ee6125099c14cb2b.png||alt="image-20220819093730-19.png" height="781" width="1920"]] |
|
200 |
+ |
|
201 |
+**Online monitor** |
|
202 |
+ |
|
203 |
+Monitor the each address in PLC by online monitor. Changing the state or value in PLC is also allowd. |
|
204 |
+ |
|
205 |
+{{id name="Iimage-20220819093730-20.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_21923412853b2626.png||alt="image-20220819093730-20.png" height="564" width="1607"]] |
|
206 |
+ |
|
207 |
+**Monitor edit** |
|
208 |
+ |
|
209 |
+In this mode, you could edit the PLC program during PLC is running. |
|
210 |
+ |
|
211 |
+{{id name="Iimage-20220819105928-9.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_9c0519bed3567723.png||alt="image-20220819105928-9.png" height="229" width="669"]] |
|
212 |
+ |
|
213 |
+== {{id name="HLX5VA0Series"/}}**LX5V Series** == |
|
214 |
+ |
|
215 |
+This example introduces the establishment of serial port communication between Wecon HMI and LX5V, including three parts: PLC software configuration, HMI software configuration, and hardware wiring. |
|
216 |
+ |
|
217 |
+**Software configuration of PLC** |
|
218 |
+ |
|
219 |
+PLC programming software |
|
220 |
+ |
|
221 |
+{{id name="Iimage-20220810164710-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_7599c2849074f02b.png||alt="image-20220810164710-1.png" height="326" width="424"]] |
|
222 |
+ |
|
223 |
+**New PLC project** |
|
224 |
+ |
|
225 |
+Click "New Project" and select the PLC model. |
|
226 |
+ |
|
227 |
+{{id name="Iimage-20220810172412-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d6bc182897bb2201.png||alt="image-20220810172412-1.png" height="898" width="1672"]] |
|
228 |
+ |
|
229 |
+**Set Serial port parameters** |
|
230 |
+ |
|
231 |
+Follow the steps below to configure Serial port parameters. |
|
232 |
+ |
|
233 |
+* Baud rate:115200 |
|
234 |
+* Data bit:8 |
|
235 |
+* Stop bit:1 |
|
236 |
+* Parity:No verification |
|
237 |
+ |
|
238 |
+{{id name="Iimage-20220810165759-3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_6b7effc40ae03777.png||alt="image-20220810165759-3.png" height="1029" width="1920"]] |
|
239 |
+ |
|
240 |
+**Registers list** |
|
241 |
+ |
|
242 |
+{{id name="Iimage-20220811102219-3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_eb0d8d9280761af1.png||alt="image-20220811102219-3.png" height="658" width="1226"]] |
|
243 |
+ |
|
244 |
+**HMI software configuration** |
|
245 |
+ |
|
246 |
+HMI programming software |
|
247 |
+ |
|
248 |
+{{id name="Iimage-20220810171237-4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d127b46be5bf7497.png||alt="image-20220810171237-4.png" height="419" width="673"]] |
|
249 |
+ |
|
250 |
+**New HMI project** |
|
251 |
+ |
|
252 |
+Click New Project and select the HMI model. |
|
253 |
+ |
|
254 |
+{{id name="Iimage-20220810172010-5.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_e73d0d6216dbf983.png||alt="image-20220810172010-5.png" height="912" width="1697"]] |
|
255 |
+ |
|
256 |
+Set communication port parameters |
|
257 |
+ |
|
258 |
+Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. |
|
259 |
+ |
|
260 |
+* Baud rate:115200 |
|
261 |
+* Data bit:8 |
|
262 |
+* Stop bit:1 |
|
263 |
+* Parity:No verification |
|
264 |
+ |
|
265 |
+{{id name="Iimage-20220811104012-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_dac87f79e1471c71.png||alt="image-20220811104012-1.png" height="965" width="1383"]] |
|
266 |
+ |
|
267 |
+**hardware connection** |
|
268 |
+ |
|
269 |
+Hardware wiring diagram |
|
270 |
+ |
|
271 |
+This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: |
|
272 |
+ |
|
273 |
+{{id name="Iimage-20220811103005-4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_dab0150e5cf17042.png||alt="image-20220811103005-4.png" height="150" width="681"]] |
|
274 |
+ |
|
275 |
+{{id name="Iimage-20220811103227-7.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d72bd5e65a0f052c.png||alt="image-20220811103227-7.png" height="209" width="342"]] |
|
276 |
+ |
|
277 |
+The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. |
|
278 |
+ |
|
279 |
+== {{id name="HLX5V-NEthernet"/}}**LX5V-N Ethernet** == |
|
280 |
+ |
|
281 |
+{{id name="cke_bm_147709S"/}} This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V, including three parts: PLC software configuration, HMI software configuration, and hardware wiring. |
|
282 |
+ |
|
283 |
+**Software configuration of PLC** |
|
284 |
+ |
|
285 |
+**PLC programming software** |
|
286 |
+ |
|
287 |
+{{id name="Iimage-20220810164710-1.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_7599c2849074f02b.png||alt="image-20220810164710-1.png" height="326" width="424"]] |
|
288 |
+ |
|
289 |
+**New PLC project** |
|
290 |
+ |
|
291 |
+Click New Project and select the PLC model. |
|
292 |
+ |
|
293 |
+{{id name="Iimage-20220811115454-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ff2c1cc959b53fdd.png||alt="image-20220811115454-1.png" height="930" width="1699"]] |
|
294 |
+ |
|
295 |
+**Set Ethernet port parameters** |
|
296 |
+ |
|
297 |
+Follow the steps below to configure Ethernet parameters |
|
298 |
+ |
|
299 |
+* PLC IP address:192.168.39.200 |
|
300 |
+* default gateway:192.168.39.1 |
|
301 |
+* subnet mask:255.255.255.0 |
|
302 |
+ |
|
303 |
+{{id name="Iimage-20220811140530-2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_60404ed3c7204071.png||alt="image-20220811140530-2.png" height="1031" width="1920"]] |
|
304 |
+ |
|
305 |
+**Registers list** |
|
306 |
+ |
|
307 |
+{{id name="Iimage-20220811102219-3.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_eb0d8d9280761af1.png||alt="image-20220811102219-3.png" height="658" width="1226"]] |
|
308 |
+ |
|
309 |
+**HMI software configuration** |
|
310 |
+ |
|
311 |
+HMI programming software |
|
312 |
+ |
|
313 |
+{{id name="Iimage-20220810171237-4.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_d127b46be5bf7497.png||alt="image-20220810171237-4.png" height="419" width="673"]] |
|
314 |
+ |
|
315 |
+**New HMI project** |
|
316 |
+ |
|
317 |
+Click New Project and select the HMI model. |
|
318 |
+ |
|
319 |
+{{id name="Iimage-20220810172010-5.png-1"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_e73d0d6216dbf983.png||alt="image-20220810172010-5.png" height="912" width="1697"]] |
|
320 |
+ |
|
321 |
+**Set communication port parameters** |
|
322 |
+ |
|
323 |
+Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. |
|
324 |
+ |
|
325 |
+* HMI IP address:192.168.39.201 |
|
326 |
+* Default gateway:192.168.39.1 |
|
327 |
+* Subnet mask:255.255.255.0 |
|
328 |
+ |
|
329 |
+{{id name="Iimage-20220811170753-2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_94717717b08e9074.png||alt="image-20220811170753-2.png" height="1008" width="1920"]] |
|
330 |
+ |
|
331 |
+Next, click Communication Settings to configure the IP of the HMI communication object. |
|
332 |
+ |
|
333 |
+{{id name="Iimage-20220811163047-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_291564bcc9db7b1b.png||alt="image-20220811163047-1.png" height="1030" width="1920"]] |
|
334 |
+ |
|
335 |
+**Hardware connection** |
|
336 |
+ |
|
337 |
+This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: |
|
338 |
+ |
|
339 |
+{{id name="Iimage-20220811170248-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_dcab5cd2ecf22982.png||alt="image-20220811170248-1.png" height="199" width="779"]] |
|
340 |
+ |
|
341 |
+The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. |