Changes for page Xinje

Last modified by Hunter on 2023/09/22 15:23

From version 15.1
edited by Hunter
on 2023/09/22 14:29
Change comment: There is no comment for this version
To version 17.1
edited by Hunter
on 2023/09/22 15:23
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,5 +1,7 @@
1 1  = **XC MODBUS** =
2 2  
3 +Support Series: Xinjie XC Series
4 +
3 3  **HMI Settings**
4 4  
5 5  |**Item**|**Settings**|**Note**
... ... @@ -9,38 +9,55 @@
9 9  |Data bit|8|
10 10  |Parity|EVEN|
11 11  |Stop bit|1|
12 -|PLC station No.|1|
14 +|PLC station No.|1|Need to be same as PLC setting
13 13  
14 14  **Address List**
15 15  
16 -|=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
17 -|Bit|M|M|M d|0~~8511|
18 -|Bit|X|X|X o|0~~1747|
19 -|Bit|Y|Y|Y o|0~~1747|
20 -|Bit|S|S|S d|0~~1023|
21 -|Bit|T|T|T d|0~~4095|
22 -|Bit|C|C|C d|0~~634|
23 -|Word|D|D|D d|0~~8511|
24 -|Word|TD|TD|TD d|0~~618|
25 -|Word|CD|CD|CD d|0~~634|
26 -|Word|FD|FD|FD d|0~~8511|
18 +|=**Type**|=(% style="width: 301px;" %)**Device registers**|=(% style="width: 235px;" %)**Format**|=**Range**|=**Note**
19 +|(% colspan="1" rowspan="6" %)Bit|(% style="width:301px" %)M|(% style="width:235px" %)MDDDD|0~~8511|Internal Relay
20 +|(% style="width:301px" %)X|(% style="width:235px" %)XOOOO|0~~1747|Input Relay
21 +|(% style="width:301px" %)Y|(% style="width:235px" %)YOOOO|0~~1747|Output Relay
22 +|(% style="width:301px" %)S|(% style="width:235px" %)SDDDD|0~~1023|Flow
23 +|(% style="width:301px" %)T|(% style="width:235px" %)TDDD|0~~618|Timer
24 +|(% style="width:301px" %)C|(% style="width:235px" %)CDDD|0~~634|Counter
25 +|(% colspan="1" rowspan="4" %)Word|(% style="width:301px" %)D|(% style="width:235px" %)DDDDD|0~~8511|Data Register
26 +|(% style="width:301px" %)TD|(% style="width:235px" %)TDDDD|0~~618|Timer
27 +|(% style="width:301px" %)CD|(% style="width:235px" %)CDDDD|0~~634|Counter
28 +|(% style="width:301px" %)FD|(% style="width:235px" %)FDDDDD|0~~8511|FlashROM Register
27 27  
28 -**Configure the communication protocol**
30 +**PLC Settings**
29 29  
30 -{{id name="Iimage-20220830154105-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_5150b44e12bc052d.png||alt="image-20220830154105-1.png" height="735" width="616"]]
32 +Create the new project, and select the specific model according to the actual PLC
31 31  
32 -{{id name="Iimage-20220830154159-3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_8ca0135815f1b6dd.png||alt="image-20220830154159-3.png" height="905" width="1038"]]
34 +(% style="text-align:center" %)
35 +[[image:XinjieXCcreatenew.png]]
33 33  
34 -**Cable Wiring**
37 +Program the PLC
35 35  
36 -Figure
39 +(% style="text-align:center" %)
40 +[[image:XinjieXCPrg.png]]
37 37  
38 -{{id name="Iimage-20220830155728-4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ef557d084f69a7e1.png||alt="image-20220830155728-4.png" height="203" width="846"]]
42 +Connect PLC with PC through RS232-USB converter cable. Click [Option]-[Software Serial Port Config] to open the software connection setup window, and select the serial port, if the red text prompt "Connect To PLC Succeeded", which means the connection is setup successfully, then click OK to save the settings.
39 39  
40 -Pin Definition Diagram
44 +(% style="text-align:center" %)
45 +[[image:XinjieXCPCconn.png]]
41 41  
42 -{{id name="Iimage-20220830154131-2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_58247140e9fe4230.png||alt="image-20220830154131-2.png" height="240" width="395"]]
47 +Change the PLC communication setup if required. Double click the tree node [PLC Serial Port] from Project tree. And change Modbus parameters, then click [Write to PLC] and OK to finish.
43 43  
49 +(% style="text-align:center" %)
50 +[[image:XinjieXCPLCModbusConfig.png]]
51 +
52 +Click [Online]-[Download Program] to download program into PLC. And the download pop up window would pop up, then click OK.
53 +
54 +(% style="text-align:center" %)
55 +[[image:XinjieXCDownloadPLC.png]]
56 +
57 +**Cable Wiring**
58 +
59 +
60 +(% style="text-align:center" %)
61 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_58247140e9fe4230.png||alt="image-20220830154131-2.png" height="240" width="395"]]
62 +
44 44  = **XD/XE MODBUS** =
45 45  
46 46  Supported Series: Xinjie XD Series
XinjieXCDownloadPLC.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +85.3 KB
Content
XinjieXCPCconn.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +65.7 KB
Content
XinjieXCPLCModbusConfig.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +47.1 KB
Content
XinjieXCPrg.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +6.4 KB
Content
XinjieXCcreatenew.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +36.7 KB
Content