1 | = **XC MODBUS** = | ||
2 | |||
3 | **HMI Settings** | ||
4 | |||
5 | |**Item**|**Settings**|**Note** | ||
6 | |Protocol|XINJE XC MODBUS| | ||
7 | |Connection|RS232| | ||
8 | |Baud rate|19200| | ||
9 | |Data bit|8| | ||
10 | |Parity|EVEN| | ||
11 | |Stop bit|1| | ||
12 | |PLC station No.|1| | ||
13 | |||
14 | **Address List** | ||
15 | |||
16 | |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** | ||
17 | |Bit|M|M|M d|0~~8511| | ||
18 | |Bit|X|X|X o|0~~1747| | ||
19 | |Bit|Y|Y|Y o|0~~1747| | ||
20 | |Bit|S|S|S d|0~~1023| | ||
21 | |Bit|T|T|T d|0~~4095| | ||
22 | |Bit|C|C|C d|0~~634| | ||
23 | |Word|D|D|D d|0~~8511| | ||
24 | |Word|TD|TD|TD d|0~~618| | ||
25 | |Word|CD|CD|CD d|0~~634| | ||
26 | |Word|FD|FD|FD d|0~~8511| | ||
27 | |||
28 | **Configure the communication protocol** | ||
29 | |||
30 | {{id name="Iimage-20220830154105-1.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_5150b44e12bc052d.png||alt="image-20220830154105-1.png" height="735" width="616"]] | ||
31 | |||
32 | {{id name="Iimage-20220830154159-3.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_8ca0135815f1b6dd.png||alt="image-20220830154159-3.png" height="905" width="1038"]] | ||
33 | |||
34 | **Cable Wiring** | ||
35 | |||
36 | Figure | ||
37 | |||
38 | {{id name="Iimage-20220830155728-4.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_ef557d084f69a7e1.png||alt="image-20220830155728-4.png" height="203" width="846"]] | ||
39 | |||
40 | Pin Definition Diagram | ||
41 | |||
42 | {{id name="Iimage-20220830154131-2.png"/}}[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_58247140e9fe4230.png||alt="image-20220830154131-2.png" height="240" width="395"]] | ||
43 | |||
44 | = **XD/XE MODBUS** = | ||
45 | |||
46 | Supported Series: Xinjie XD Series | ||
47 | |||
48 | **HMI Settings** | ||
49 | |||
50 | |=**Item**|=**Settings**|=**Note** | ||
51 | |Protocol|XINJE XD/XC MODBUS| | ||
52 | |Connection|RS232| | ||
53 | |Baud rate|19200| | ||
54 | |Data bit|8| | ||
55 | |Parity|EVEN| | ||
56 | |Stop bit|1| | ||
57 | |PLC station No.|1|Need to be same as PLC setting | ||
58 | |||
59 | **Address List** | ||
60 | |||
61 | |=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** | ||
62 | |(% colspan="1" rowspan="18" %)Bit|M|MDDDDD|0~~74999|Internal Relay | ||
63 | |X1xx|X1xxOOOO|0~~1177|Extension Module Input Relay | ||
64 | |X2xx|X2xxOOO|0~~277|BD Card Input Relay | ||
65 | |X|XOO|0~~77|Input Relay | ||
66 | |Y1xx|Y1xxOOOO|0~~1177|Extenson Module Output Relay | ||
67 | |Y2xx|Y2xxOOO|0~~277|BD Card Output Relay | ||
68 | |Y|YOOOO|0~~77|Output Relay | ||
69 | |SM|SMDDDD|0~~4999|Special Auxiliary Relay | ||
70 | |T|TDDDD|0~~4999|Timer | ||
71 | |C|CDDDD|0~~4999|Counter | ||
72 | |ET|ETDD|0~~31|Precise Timer | ||
73 | |SE|SEDD|0~~31| | ||
74 | |HM|HMDDDDD|0~~11999| | ||
75 | |HSC|HSCDD|0~~39| | ||
76 | |HS|HSDDD|0~~999| | ||
77 | |HT|HTDDDD|0~~1999| | ||
78 | |HC|HCDDDD|0~~1999| | ||
79 | |S|SDDDD|0~~7999| | ||
80 | |(% colspan="1" rowspan="19" %)Word|D|DDDDDD|0~~69999|Data Register | ||
81 | |ID|IDDD|0~~99|Analog Input | ||
82 | |ID1xx|ID1xxDDD|0~~999|Extension Module Analog Input | ||
83 | |ID2xx|ID2xxDDD|0~~299|BD Card Analog Input | ||
84 | |QD|QDDD|0~~99|Analog Output | ||
85 | |QD1xx|QD1xxDDD|0~~999|Extension Module Analog Output | ||
86 | |QD2xx|QD2xxDDD|0~~299|BD Card Analog Output | ||
87 | |SD|SDDDDD|0~~4999|Data Register | ||
88 | |TD|TDDDD|0~~575|Timer | ||
89 | |CD|CDDDD|0~~575|Counter | ||
90 | |ETD|ETDDD|0~~31|Precise Timer | ||
91 | |HD|HDDDDDD|0~~24999|Data Register | ||
92 | |HSD|HSDDDDD|0~~1023|Power Off Retentive Data Register | ||
93 | |HTD|HTDDD|0~~95|Power Off Retentive Timer | ||
94 | |HCD|HCDDD|0~~95|Power Off Retentive Counter | ||
95 | |HSCD|HSCDDD|0~~31|High Speed Counter | ||
96 | |FD|FDDDDD|0~~8191|FlashROM Register | ||
97 | |SFD|SFDDDDD|0~~5999|Special Flash Register | ||
98 | |FS|FSDD|0~~47|Special Data Register | ||
99 | |||
100 | **PLC Settings** | ||
101 | |||
102 | Create the new project, and select the specific model according to the actual PLC | ||
103 | |||
104 | (% style="text-align:center" %) | ||
105 | [[image:XinjieXDcreatenew.png]] | ||
106 | |||
107 | Program the PLC | ||
108 | |||
109 | (% style="text-align:center" %) | ||
110 | [[image:XinjieXDLDprg.png]] | ||
111 | |||
112 | Connect PLC with PC through RS232-USB converter cable. Click [Option]-[Software Serial Port Config]-[Communication configuration] to open the PC connection configuration. | ||
113 | |||
114 | (% style="text-align:center" %) | ||
115 | [[image:XinjieXDopenSWcom.png]] | ||
116 | |||
117 | New a Modbus configuration, and Click [Comm-Test] to test connection, if shows "Connect To PLC Succeeded", which means PLC connection set up successfully. And click OK to save the settings | ||
118 | |||
119 | (% style="text-align:center" %) | ||
120 | [[image:XinjieXDPLCtestconn.png]] | ||
121 | |||
122 | Remember to click the Status cell of new created Modbus configuration for change the status into "in use", then click OK to exit. | ||
123 | |||
124 | (% style="text-align:center" %) | ||
125 | [[image:XinjieXDclickto.png]] | ||
126 | |||
127 | After done the previous steps, it would prompt like the below | ||
128 | |||
129 | (% style="text-align:center" %) | ||
130 | [[image:XinjieXDsuccessprompt.png]] | ||
131 | |||
132 | Change the PLC communication setup if required. Click [Configure]-[PLC Comm Port Settings]-[Add]-[Modbus]. After parameters are modified, click [Write to PLC]. | ||
133 | |||
134 | (% style="text-align:center" %) | ||
135 | [[image:XinjieXDSetPLCcom0.png]] | ||
136 | |||
137 | If wrote to PLC successfully, it would prompt like the below | ||
138 | |||
139 | (% style="text-align:center" %) | ||
140 | [[image:XinjieXDwriteComparadone.png]] | ||
141 | |||
142 | Click [Online]-[Download Program & Data], and wait for a while, the pop up window would ask for whether to stop PLC, and click [Stop PLC, contitue download] | ||
143 | |||
144 | (% style="text-align:center" %) | ||
145 | [[image:XinjieXDdownload.png]] | ||
146 | |||
147 | And then the XDPro ask for which options want to rewrite, and click OK to finish. | ||
148 | |||
149 | (% style="text-align:center" %) | ||
150 | [[image:XinjieXDdownloadopt.png]] | ||
151 | |||
152 | If download successfully, it would prompt like the below | ||
153 | |||
154 | (% style="text-align:center" %) | ||
155 | [[image:XinjieXDcomplete.png]] | ||
156 | |||
157 | **Cable Wiring** | ||
158 | |||