Changes for page 02 Introduction

Last modified by Mora Zhou on 2024/12/05 15:52

From version 9.1
edited by Mora Zhou
on 2023/11/28 11:27
Change comment: There is no comment for this version
To version 1.2
edited by Leo Wei
on 2022/06/09 16:01
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -PLC Editor.WebHome
1 +PLC Editor.1 User Manual.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Mora
1 +XWiki.admin
Content
... ... @@ -5,7 +5,7 @@
5 5  WECON PLC has the built-in battery, CPU and I/O points. The PLC CPU could connect with I/O expansion modules to expend the I/O point number or connect with some special function expansion modules.
6 6  
7 7  (% style="text-align:center" %)
8 -[[image:1617848880215-357.png||height="392" width="700" class="img-thumbnail"]]
8 +[[image:1617848880215-357.png||class="img-thumbnail" height="392" width="700"]]
9 9  
10 10  Figure 1
11 11  
... ... @@ -30,17 +30,10 @@
30 30  1. BD board slot
31 31  
32 32  (% style="text-align:center" %)
33 -[[image:2.WECON PLC introduction_html_2ab1ae49c4b64094.jpg||height="254" width="700" class="img-thumbnail"]]
33 +[[image:2.WECON PLC introduction_html_2ab1ae49c4b64094.jpg||class="img-thumbnail" height="254" width="700"]]
34 34  
35 35  Figure 2
36 36  
37 -
38 -RS422 communication cable drawing
39 -
40 -[[image:企业微信截图_16749852553667.png]]
41 -
42 -Figure 3
43 -
44 44  = **2.2 Expansion module** =
45 45  
46 46  WECON PLC has many kinds of expansion modules, including I/O module, analog input and output module, high speed output module and Ethernet communication protocol.
... ... @@ -57,25 +57,25 @@
57 57  1. Mounting hole(⌀:4.5)
58 58  
59 59  (% style="text-align:center" %)
60 -[[image:1617848918114-171.png||height="406" width="500" class="img-thumbnail"]]
53 +[[image:1617848918114-171.png||class="img-thumbnail" height="406" width="500"]]
61 61  
62 -Figure 4
55 +Figure 3
63 63  
64 64  The PLC CPU and the expansion module are the same size in height and depth, but different width. So they could connect with each other in a neat form, also the configuration is flexible.
65 65  
66 66  (% style="text-align:center" %)
67 -[[image:2.WECON PLC introduction_html_e5b6cb69a43842b4.jpg||height="293" width="800" class="img-thumbnail"]]
60 +[[image:2.WECON PLC introduction_html_e5b6cb69a43842b4.jpg||class="img-thumbnail" height="293" width="800"]]
68 68  
69 -Figure 5
62 +Figure 4
70 70  
71 -= **2.3 BD module** =
64 += **2.3 BD board** =
72 72  
73 -Compared with expansion module, BD module is smaller, more flexible (up to 2 BD modules in one PLC) and cheaper, but also with multi-function. Because the BD module is installed in the host unit, so it will not occupy extra space.
66 +Compared with expansion module, BD board is smaller, more flexible (up to 2 BD boards in one PLC) and cheaper, but also with multi-function. Because the BD board is installed in the host unit, so it will not occupy extra space.
74 74  
75 75  (% style="text-align:center" %)
76 -[[image:1617848958334-935.png||height="231" width="700" class="img-thumbnail"]]
69 +[[image:1617848958334-935.png||class="img-thumbnail" height="231" width="700"]]
77 77  
78 -Figure 6
71 +Figure 5
79 79  
80 80  = **2.4 Dimension** =
81 81  
... ... @@ -84,7 +84,7 @@
84 84  (% style="text-align:center" %)
85 85  [[image:1617848968476-703.png||height="294" width="700" class="img-thumbnail"]]
86 86  
87 -Figure 7
80 +Figure 6
88 88  
89 89  Mount the plc in the DIN (35mm) rail directly. Gently pull out the DIN rail mounting clip from below, then we could remove the main unit from DIN rail. The mounting holes could be used to directly mount the programmable controller with M4 screws. Please refer to the following table for the pitch and location of mounting holes.
90 90  
... ... @@ -100,16 +100,16 @@
100 100  == **2.4.2 Expansion module** ==
101 101  
102 102  (% style="text-align:center" %)
103 -[[image:1617848984586-696.png||height="292" width="650" class="img-thumbnail"]]
96 +[[image:1617848984586-696.png||class="img-thumbnail" height="292" width="650"]]
104 104  
105 -Figure 8
98 +Figure 7
106 106  
107 -== **2.4.3 BD module** ==
100 +== **2.4.3 BD board** ==
108 108  
109 109  (% style="text-align:center" %)
110 -[[image:1617848979413-720.png||height="251" width="600" class="img-thumbnail"]]
103 +[[image:1617848979413-720.png||class="img-thumbnail" height="251" width="600"]]
111 111  
112 -Figure 9
105 +Figure 8
113 113  
114 114  = **2.5 PLC series function appendix** =
115 115  
... ... @@ -116,7 +116,7 @@
116 116  The naming rules of Wecon PLC:
117 117  
118 118  (% style="text-align:center" %)
119 -[[image:image-20220623111807-1.png]]
112 +[[image:http://docs.we-con.com.cn/wiki/plc/download/2-User%20manual/3.WECON%20PLC%20introduction/Wecon%20PLC%20series%20function%20appendix/WebHome/%E7%BB%B4%E6%8E%A7PLC%E7%B3%BB%E5%88%97%E5%8A%9F%E8%83%BD%E9%99%84%E5%BD%95_Eng_html_901d65f8023d85d4.png?width=494&height=111&rev=1.3||alt="维控PLC系列功能附录_Eng_html_901d65f8023d85d4.png" height="126" width="561"]]
120 120  
121 121  ①~⑥ in the model name composition indicate the following specifications:
122 122  
... ... @@ -136,8 +136,6 @@
136 136  
137 137  **⑥ Instruction set:** 1=1S instruction set; 2=2N instruction set, none = default 2N instruction set.
138 138  
139 -(% class="box infomessage" %)
140 -(((
141 141  **✎Note:**
142 142  
143 143  1. The 1S instruction set does not support floating-point operations.
... ... @@ -145,7 +145,6 @@
145 145  1. The LX3VP series is an upgraded version of the LX3V series, which adds N:N network communication function, RSLIST tabularization, DVIT interrupt positioning instruction, PLSR2 multi-speed high-speed instruction, and supports ETH-BD (Ethernet module) and CAN module.
146 146  1. The LX3VE series is an upgraded version of the LX3V series, which adds electronic cam, S-cam function, N:N network communication function, linear interpolation function, RSLIST table command, DVIT interrupt positioning command function, and supports ETH-BD (Ethernet module) .
147 147  1. The LX3VM series is an upgraded version of the LX3VE series, which adds the arc interpolation function, but does not support ETH-BD (Ethernet module).
148 -)))
149 149  
150 150  **The specific function parameters are shown in the figure below:**
151 151  
... ... @@ -212,7 +212,4 @@
212 212  |**CCPID instruction**|**×**|**×**|**×**|**×**
213 213  |**SCL**|**×**|**×**|**×**|**×**
214 214  
215 -(% class="box infomessage" %)
216 -(((
217 217  **✎Note: **Only supported by special versions, please consult relevant personnel for details.
218 -)))
image-20220623111807-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Stone
Size
... ... @@ -1,1 +1,0 @@
1 -271.1 KB
Content
企业微信截图_16749852553667.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Jim
Size
... ... @@ -1,1 +1,0 @@
1 -80.4 KB
Content